This everyday Multifunction Tester ideal for domestic use and covers all the basic needs for testing to the 17th Edition Wiring Regulations and Part P of the Building Regulations. The Fluke 1651B Multifunction Installation Tester can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364, HD 384 and all relevant local standards.
Calibration certificate is included
| Range: | 500 V |
| Resolution: | 0.1 V |
| Accuracy (50 - 60 Hz) | ± (0.8% + 3 digits) |
| Input Impedance | 3.3 MΩ |
| Overload Protection | 660 Vrms |
| Range (autoranging): | 20 Ω, 200 Ω, 2000 Ω |
| Resolution: | 0.01 Ω, 0.1 Ω, 1 Ω |
| Test Current: | > 200 mA |
| Open Circuit Voltage: | > 4 V |
| Accuracy: | ± (1.5%+3 digits) |
| Test Voltage: | |
| Fluke 1651B: | 250 - 500 - 1000 V |
| Fluke 1652B: | 250 - 500 - 1000 V |
| Fluke 1653B: | 50 - 100 - 250 - 500 - 1000 V |
| Test Voltage: | 50 V |
| Test Current: | 1 mA @ 50 kΩ |
| Insulation Range: | 10 kΩ - 50 мΩ |
| Resolution: | 0.01 мΩ |
| Accuracy: | ± (3% + 3 digits) |
| Test Voltage: | 100 V |
| Test Current: | 1 mA @ 100 kΩ |
| Range/Resolution: | 20 MΩ/0.01 MΩ |
| Range/Resolution: | 100 MΩ/0.1 MΩ |
| Accuracy: | ± (3% + 3 digits) |
| Test Voltage: | 250 V |
| Test Current: | 1 mA @ 250 kΩ |
| Range/Resolution: | 20 MΩ/0.01 MΩ |
| Range/Resolution: | 200 MΩ/0.1 MΩ |
| Accuracy: | ± (1.5% + 3 digits) |
| Test Voltage: | 500 V |
| Test Current: | 1 mA @ 500 kΩ |
| Range/Resolution: | 20 MΩ/0.01 MΩ |
| Range/Resolution: | 200 MΩ/0.1 MΩ |
| Accuracy: | ± (1.5% + 3 digits) |
| Range/Resolution: | 500 MΩ/1 MΩ |
| Accuracy: | 10% |
| Test Voltage: | 1000 V |
| Test Current: | 1 mA @ 1 MΩ |
| Range/Resolution: | 20 MΩ/0.01 MΩ |
| Range/Resolution: | 200 MΩ/0.1 MΩ |
| Accuracy: | ± (1.5% + 3 digits) |
| Range/Resolution: | 500 MΩ/1 MΩ |
| Accuracy: | 10% |
| Auto Discharge: | Discharge time constant, 0.5 second for C = 1 µF or less |
| Live Circuit Detection: | Inhibits test if terminal voltage > 30 V prior to initiation of test |
| Maximum Capacitive Load: | Operable with the 5 µF load |
| Range: | 100 - 500 VAC (50/60 Hz) |
| Input connection: | Soft Key selection |
| Loop impedance: | Phase to earth |
| Line impedance: | Phase to neutral |
| Limit on consecutive tests: | Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical) |
| Max. Test Current High Current Mode: | |
| Non-Trip Mode: | |
| Range/Resolution: | 20 Ω/0.01 Ω |
| Range/Resolution: | 200 Ω/0.1 Ω |
| Range/Resolution: | 2000 Ω/1 Ω |
| Accuracy (no Trip mode): | ± (3% + 6 digits) |
| Accuracy (Hi Current mode): | ± (2% + 4 digits) |
| Computation: | PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance |
| Range: | 0 - 25 kA |
| Resolution (Ik < 1000 A): | 1 A |
| Resolution (Ik >= 1000 A): | 0.1 kA |
| Accuracy: | Determined by accuracy of loop resistance and mains voltage measurements. |
Operating Temperature -10 °C to 40 °C
Humidity (Without Condensation) 10 to 30 °C: 95%, 30 to 40 °C:75
Fluke 1651B with half price Calibration Checkbox


Fluke 1651B with Electricians Accessory Bundle 1 for only £69