Part of megger’s PAT 400 range the PAT 420 testing machine is part of the latest generation of test equipment, which features a high duty cycle allowing for quick testing and continuous use all day long.
Built for the modern engineer the PAT 420 is specifically designed for easy downloading to a computer. The ability to properly manage and analyse information from a site inspection can be vital to a PAT company’s growth as it allows for the management of a company’s clients as well as printing of PAT certificates.
The PAT 420 features the unique re-start technology allowing this device to be moved around a site and restart to the same menu saving an engineer’s time and increasing productivity. Another time saving feature of this tester is the five soft touch buttons allowing for the most commonly used functions to be recalled both quickly and accurately.
Megger PAT420 Portable Appliance Tester key features
Megger PAT420 PAT Tester suitability
Megger PAT420 Test Instrument comes supplied with
Further information:
PAT410: 230 V ± 10% @ 50 Hz
PAT420, PAT450: 110 V ± 10% + 110 V ±10% @ 50 HZ
Open circuit voltage: 9 V a.c. ± 10% ± 0.1 V (Supply: 230 V 50Hz)
Earth bond resistance accuracy:
±5% ±3 digits (0 to 0.49 Ω)
±5% ±5 digits 0.5 to .99 Ω)
Earth bond resistance resolution: 10 mΩ (0 to 1.99 Ω)
Display range: 0 to 1.99 Ω
Continuity test voltage: 4.0 V d.c. -0% +10%
Continuity resistance accuracy:
±5% ±3 digits (0 to 0.49 Ω)
±5% ±5 digits 0.5 to .99 Ω)
Continuity resistance resolution: 10 mΩ (1 to 19.99 Ω)
Display range: 0 to 19.99 Ω
Insulation resistance accuracy (230 V):
±2% ±5 digits (0 to 19.99 MΩ)
±5% ±10 digits (20 to 99.99 MΩ)
Insulation resistance resolution: 0.01 MΩ
Display range: 0 to 99.99 MΩ
Test voltage and frequency: 40 V a.c. ±10% nominal mains frequency
Leakage current accuracy: ±5% ±5 digits
Leakage current resolution: 0.01 mA
Display range: 0 to 19.99 mA
Test voltage and frequency: Nominal mains supply
Differential leakage current accuracy: ±5% ±5 digits
Differential leakage current resolution: 0.01 mA
Display range: 0 to 19.99 mA
Test voltage and frequency: Nominal mains supply
Touch current accuracy: ±5% ±5 digits
Touch current resolution: 0.01 mA
Display: 0 to 10 mA
Test voltage and frequency: Nominal mains supply
VA accuracy:
±5% ±10 digits (0 - 99 VA)
±5% ±50 digits (100 VA - 999 VA)
±5% ±100 digits (1000 VA - 3700 VA)
Resolution: 1 VA (0 to 3700 VA)
Display range: 0 to 3999 VA
Tests performed: Bond, insulation and polarity
Polarity test voltage: 12 V
Polarity checks:
Lead OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Flash test voltage:
1500 V a.c. nominal for Class 1
3000 V a.c. nominal for Class 2
Flash test current: <3.5 mA short circuit @ 253 V primary supply voltage
Flash test breakdown current accuracy: ±5% ±5 digits
Flash test breakdown current resolution: 0.01 mA
Display range: 0 to 3.0 mA
Test voltage and frequency: Nominal mains supply
Test current accuracy:
-8% to -2% (1/2 x I)
+2% to +8% (1 x I, 5 x I)
Trip time accuracy: ±1% ±5 digits
Trip time resolution: 0.1 ms
Display range:
0 to 1999 ms (1/2 x I)
0 to 300 ms (1 x I)
0 to 40 ms (5 x I)
Test voltage: 3.3 V
Warning: Audible beep if fuse is OK
Operating temperature: -10 to +50 ºC
Storage temperature: -20 to +60 ºC
Humidity:
90% RH @ -10 to +30 ºC
75% RH @ +30 to +50 ºC
Maximum altitude: 2000 m
Ingress protection: IP40
PAT410 (with packaging): 2.7 kg (3.2 kg)
PAT420 (with packaging): 4.4 kg (4.9 kg)
PAT450 (with packaging): 5.0 kg (5.5 kg)
PAT410: 145 (H) x 255 (W) x 320 (L)
PAT420 & PAT450: 180 (H) x 255 (W) x 320 (L)
Packaging: 210 (H) x 280 (W) x 390 (L)
IEC 61010-1: CAT II 300 V
IEC 61326-1: 2006
IEC 61326-2-2: 2005