All Seaward Products

Seaward Apollo 500+ PAT Tester - New 5th Edition

SKU
380A928
Rating:
67%
(1)
Reward Points
:
1171
£1,405.20 £1,171.00
In Stock Free UK Delivery*
Choose a Special Offer
  •  PASS Training USB with Exam, Pass & Fail Labels (PTPROMO7)
    PASS Training Online Course with Exam, Pass & Fail Labels
    FREE
    £93.27
  • PASS Training Online Course with Exam, Pass & Fail Labels SKU: (PTPROMO7)
    FREE
    £93.27
     PASS Training USB with Exam, Pass & Fail Labels (PTPROMO7)
  • PASS The Complete Guide to EET (PAT) Testing Cover
    PASS The Complete Guide to EET (PAT) Testing, 5th Edition
    FREE
    £24.99
  • PASS The Complete Guide to EET (PAT) Testing, 5th Edition SKU: (PASS-PAT-HB)
    FREE
    £24.99
    PASS The Complete Guide to EET (PAT) Testing Cover
  • Schneider Kit - Analogue Multimeter, Voltage Detector, & Socket Tester
    Schneider Kit - Analogue Multimeter, Voltage Detector, & Socket Tester
    FREE
    £42.00
  • Schneider Kit - Analogue Multimeter, Voltage Detector, & Socket Tester SKU: (SCH-PROMO)
    FREE
    £42.00
    Schneider Kit - Analogue Multimeter, Voltage Detector, & Socket Tester
Advice & Support
Price Match Request
FREE Accessory Bundle
Seaward Apollo 500+ PAT Tester in hand

 

Seaward Apollo PATs

The Seaward Apollo 500+ 5th Edition PAT Tester is an updated version of Seaward’s Apollo 500+ PAT Tester and is compliant with the new code of practice, this includes Class 2 FE, protective and touch leakage limits to 5mA (as the new code of practice now requires testers to have a pass-fail limit of 5mA for all leakage tests) as well as other new tests as per the 5th Edition.

Seaward Apollo 500+ PAT Tester | Introduction | Key Features

The new 5th Edition firmware will also be available to download free of charge for current Apollo users who will be able to update to the new firmware and benefit from the new test features.

Note: in existing Apollos touch current tests will be limited by the hardware to 3.5mA.

The Seaward 5th Edition Apollo 500+ keeps the same features that made the 500+ an unrivalled PAT tester but now includes firmware and hardware updates to ensure it is compliant with the release of the 5th Edition Code of Practice. 

Apollo 500+ PAT Tester Overview Video

Seawards Apollo 500+ features the ability to use QR codes (Using Seaward’s Test n Tag Elite 2 printer you can now print labels that include our unique QR data code) and is compatible with Seawards new QR Barcode scanner, meaning you can scan in a previous test and easily and quickly amend data fields. Also new is the QR DATA Viewer app (available for both Android and iOS devices) the app allows users to scan the labels and view the test information and share the data via email.

Tests Include:

  • Low current earth continuity test (with Zap circuit) guaranteeing accurate measurement
  • Insulation resistance
  • IEC lead test
  • Protective conductor current
  • Touch current
  • Load power/current
  • Alternative leakage current
  • Point to point testing of earth continuity and insulation resistance
  • RCD test
  • Power socket test
  • Class 2 FE (5th edition update) 

Hardware Features

The Apollo 500+ has the ability to exchange the external rechargeable battery pack, meaning less downtime whilst you’re PAT Testing on a larger scale, simply change the battery over and carry on testing! The 500+ still has the option to run via mains power. The 2020 5th edition hardware update also allows for the increase in protective and touch leakage limits to 5mA rather than 3.5m.A.

Firmware Features

  • User Permissions for Bluetooth
  • Delete unwanted results
  • ‘View Data Menu’ has the ability to scroll through lists faster and search functionality allows for filtering results by a number of methods including PASS/Fail status
  • Automatically print test results option added to the ‘After test’ option
  • Delete items from the predictive drop-down lists to customise it to your preferred use
  • USB on-the-go technology means you can download directly to an Android device
  • Name downloaded files with unique identifiers to find them easier
  • Socket outlet test which measures main voltage and outlet wiring polarity
  • QR Code option on the printed label as well as a free QR Data Viewer app which is available on both iOS and Android stores allowing the user to easily scan and read test data as well as share it.
  • The asset ID is displayed on all test screens allowing you to keep track of what you are currently testing
  • Review step – Check test details before making final comments
  • 2020 5th Edition update includes a brand-new set of test sequences including Class 2 FE and other new tests as per the 5th Edition

Software

The Apollo 500+ is compatible with the new PAT guard 3.4 which now includes Time Manager (Software sold separately)

Key Features:

  • 5th Edition update of the Seaward Apollo 500+
  • Brand-new set of test sequences including Class 2 FE and other new tests as per the 5th Edition
  • Onboard storage for up to 10,000 appliance records
  • Safety tests which ensure compliance with the IET 5th Edition Code of Practice
  • Interchangeable rechargeable battery
  • Create up to 100 user-configurable electrical test and visual inspection sequences
  • Point to point measurement (Rpe & IR)
  • Bluetooth, Scanner and Printer compatible
  • Remote data transfer from field to the office
  • High definition colour display
  • Suitable for mid-volume PAT Testing
  • Improved user interface for intuitive functionality and ease of use
  • Full QWERTY Keyboard
  • Ability to use (2D) QR codes
  • Fast boot-up
  • Built-in Risk-based retest calculator to quickly determine suggested retest periods
  • Plug and Play use 

Operating the Seaward Apollo+ PAT Testers

The following videos offer a brief introduction to using some of the Seaward Apollo+ PAT Testers' features. 

Switching on the Bluetooth Setting

How to turn on the Bluetooth setting in the Apollo+ Series

Setting Up a Printer to Work with the Apollo+

How to setup a printer to work with the Apollo+

Connecting a Printer to the Apollo+

How to Connect a printer with the Apollo+ Series

Pairing a 1D Scanner with the Apollo+

How to pair the 1D scanner with the Apollo+ Series

Pairing a 2D Scanner with the Apollo+

How to pair the 2D scanner with the Apollo+ Series

Uploading a Company Logo to the Apollo+ for use on Printing Labels

How to upload a company logo on the Apollo+ to use on printing lables

Uploading a Background Image to the Apollo+

How to upload a background image on the Apollo+

Changing the Background Image on the Apollo+

How to change the background image on the Apollo+

Deleting a Single Asset from the Apollo+

How to delete a single Asset on the Apollo+

Deleting Test Results from the Apollo+

How to delete test results on the Apollo+

Confirming Firmware and Calibration Information on the Apollo+

How to confirm firmware and calibration information on the Apollo+

Updating Firmware on the Apollo+

How to update the firmware on the Apollo+

Factory Resetting the Apollo+

How to Factory Re-set the Apollo+

Whats Included?

p>

Seaward Apollo 500+ PAT Tester | Unboxing Video | What's in the Box

  • Apollo 500+
  • Professional Carry Case
  • Red Test Lead 1.2m with Alligator Clip
  • Black Test Lead 1.2m with Alligator Clip
  • IEC Extension Lead, 0.5m
  • Black Mains Lead
  • USB Download Lead
  • Apollo+ Check Box
  • UKAS Calibration Certificate
  • Quick Start Guide

Test leads now feature a stronger PVC insulation and sturdier probes for more demanding usage.

Seaward Apollo 500+ Technical Specifications

Earth Continuity  
Test Current +/- 200mA DC
Display Range 0.01 – 19.99Ω
Pass Value User Defined
Insulation Resistance  
Test Voltage 500V / 250V DC @ 1mA nominal
Display Range 0.01MΩ - 19.99MΩ
Pass Value User Defined
IEC Lead Test  
Test Voltage 5V ac nominal
Test Live / Neutral Checks for o/c, s/c and crossed
Protective Conductor Current/Load  
Test Voltage Supply voltage, maximum load current 16A
Display Ranges 0.01mA to 19.99mA
Pass Value User Defined
Touch Current  
Test Voltage Supply Voltage, maximum load current 16A
Display Range 0.00 – 5mA.
Pass Value User Defined
Load Power/Current  
Test Voltage Supply Voltage, maximum load current 16A
Test Duration Programmable up to a maximum of 255s
depending on load. i.e. max duration is reduced
for high loads
Display Range 0.00kVA – 4.00kVA
0.00A – 16.00A
Alternative Leakage Current  
Test Voltages >25Vac <50Vac
Display Range 0.00mA to 19.99mA
Pass Value User Defined
RCD Test  
Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms - 2000ms (30mA), 0-40ms (150mA)
Test Method Internal isolation to avoid tripping distribution
board RCD
Power Socket Test  
Voltage Range 207V – 253V AC
Indicates configuration of voltage potential:-
Line potential phase to earth
Line potential phase to neutral
Line potential neutral to earth
General  
Memory Size 10000 Records
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or Rechargeable Battery Pack

Comparison Chart

General Features 600+ 500+ 400+
Battery & mains powered
Colour screen & QWERTY keypad
Large internal memory up to 50,000 records and 2,000 photos up to 10,000 records up to 2,000 records
Bluetooth scanner & printer compatible
Password controlled user accounts  
Set up multiple user accounts with varying levels of privileges  
Clone facility to set up multiple testers  
Checkbox supplied as standard  
Test Inspection Features 600+ 500+ 400+
Auto-increment asset ID  
PAT Setup option to allow for custom menus  
Enter asset description after test using the keypad or barcode scanner
Comprehensive electrical safety test features 
Point to point measurement (Rpe & IR)  Optional accessory required
User configurable electrical test/visual inspection sequences 100 100 25
User set sites & locations 100 100 50
Risk-based retest period calculator  
User definable comments lines against test records 4 4  
Configurable checklists for any workplace test or inspection (user tests)  
Onboard camera    
Universal risk assessment    
Health & safety certificates    
Data Transfer 600+ 500+ 400+
1D and 2D Scanner connectivity Reads 1D Data Only
Read QR code (2D) labels with 2D scanner  
RFID reader connectivity  
Print Pass & Fail labels with 1D barcode
Print Pass & Fail labels with QR code (2D)  
Add your company logo to labels (on large 1D labels only)  
Select from various label formats to print 6 6 6
Download to PC via USB cable
Data Transfer via USB flash drive    
Filter results to be downloaded
Upload previous results to the tester for a retest  
Accessories related to this product:
1 Reviews
Rating:
67%
(1)
Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Seaward Apollo 500+ PAT Tester - New 5th Edition
Your Rating
Additional Information
SKU 380A928
Manufacturer Part Code 380A928
Model Ref Apollo 500+
Country of Origin United Kingdom
International Enquiry