Call 01642 931329 for Orders & Advice

Downloadable Multifunction Installation Tester Comparison Chart

         

Struggling to find exactly the right downloadable installation tester? We can sympathise - there's loads of models out there and they all do different things, meaning picking the right one can be a tricky process.

Thankfully, we're here to help!

We've constructed this handy comparison chart to walk you through the features of our most popular downloadable installation testers, helping you to see exactly what you're getting for your money. Everything's broken down by feature by feature, so you can always be sure to find the features you need and the model that falls within your budget.

Tester is compiling comparison charts for all of our most popular equipment. These include:

This chart shows a selection of our most popular advanced and downloadable multifunction testers. To see our full range take a look at our Multifunction Testers.

  Basic Downloadable Installation testers
 


MI3101eurotestAT

MI3125B eurotest combo


MI 3102 Eurotest XE

CM500 Seaward Powerplus 1557 Installation Tester


Kewtech KT65 Digital

Seaward Powerplus 1557 Installation Tester

Megger MFT1730-BS

PRODUCER Metrel Metrel Megger Megger Seaward Kewtech Fluke Megger
MODEL MI 3101
EurotestAT
MI 3125B
EurotestCOMBO
MI 3102
Eurotest XE
CM500 PowerPlus
1557
KT 65 1653B MFT1730
PRICE
             
INSULATION              
DC test voltages (V) 50; 100; 250; 500; 1000 50; 100; 250; 500; 1000 100; 250; 500; 1000 250; 500; 1000 100, 250, 500, 1000 250, 500, 1000 50, 100, 250, 500, 1000 250; 500; 1000
EN 61557-2              
Range (MΩ) 0 , 1000 0 , 1000 0 , 1000 1k - 499M 0,00 - 200 0 - 2000 10k - 1000M 0.01…500
Autotest insulation L-PE, N-PE, L-N - - - - - - -
CONTINUITY              
Continuity R low 200mA DC
Range (Ω) 0 ,1999 (9999) 0 ,1999 0 ,1999 0,01Ω -99,9k 0,00 - 200 0 - 2000 0 - 2000 0,01Ω … 99,9k
EN 61557-4              
Automatic polarity swap - - - - -
Continuity 7 mA DC - - - - -
LINE/LOOP              
Line impedance measurement
EN 61557-3              
Loop impedance measurement
Ipsc, UL-N-PE
Loop Impedance (Trip Lock RCD) -
Built-in Fuse table for PASS/FAIL decision - - - - -
IT system: first fault leakage current - - - - - -
IT system line loop - - - -   -
RCD              
RCD type A, AC, B A, AC, B A, AC A, AC A, AC A, AC A, AC A,AC,S, B
EN 61557-6              
trip-out t / trip-out Id / Uc ✓/✓/✓ ✓/✓/✓ ✓/✓/✓ ✓/✓/✓ ✓/✓/ - ✓/✓/✓ ✓/✓/- ✓/✓/✓
RCD AUTO
Time delayed (S-type) RCD
10, 30, 100, 300, 500, 1000mA not 1000 mA
RL LOOP Resistance - - - -
VOLTAGE              
Real-time AC voltage measurement
FREQUENCY              
Simultaneous voltage measurement over 3 phases - - - - -
Frequency measurement -
PHASE SEQUENCE EN61557-7              
L1-L2-L3 -
EARTH              
3- (4-) wire earth resistance - -
Specific Earth Resistance Option - - - - - - -
AUTO SEQUENCE              
AUTO SEQUENCE procedure on SwitchBoard - - - - - - -
TESTS              
AUTO SEQUENCE procedure on Circuit - - - - - - -
Automatic evaluation of safety, based on all measured values - - - - - - -
Automatic saving of all measured values at once - - - - - - -
Preparing of Automatic printing of the report - - - - - - -
OTHER              
LUX light measurements - - Option - - - - -
Measurements              
Clamp Leakage / Load Current TRMS - - Option - - - - -
IT system: Medical sites - IMD test - - - - - -
Varistor overvoltage - - - - - - -
Fuse / fault locator Option - - - - - - -
High resolution line/loop impedance (mOhm ) Option - - - - - - -
ON LINE WARNINGS              
Touch electrode - -
INFORMATION              
HELP menu - - - -
Evaluation PASS/FAIL results - - at RCD Auto only at RCD only -
Online voltage monitor - - - - -
Communication              
RS232 - - - -
PORTS              
USB - - Optical adapter - -
Bluetooth - - - - IR port
SOFTWARE              
Memory
MEMORIES              
Number of levels / memory locations 10 lev./ 2000 3 lev./ 1700 3 lev. / 500 750 2/1000 500 1000
Custom structure upload from PC - - - - - -
Basic PC SW Option ✓ / Option Option Option
Advanced PC SW Option Option Option Option Option - Option Option
GENERAL              
Nominal Frequency 14 , 500 Hz 45 , 65 Hz 45 , 65 Hz 45 … 65 Hz 45 … 65 Hz 50 Hz 50/60 Hz 15 - 400 Hz
Reduced 55 / 63 V systems support - - - - - -
IT earthing system mode support - - - - In IT - RCD only -
Safety category CAT III / 600 V CAT IV / 300 V CAT III / 600 V CAT IV / 300 V CAT III / 600 V CAT IV / 300 V CAT III / 400 V (inp) CAT III / 230 V (gr) CAT III / 300 V CAT III / 300 V CAT III / 500 V CAT III / 300 V
IP rating 40 40 42 40 40 40 54
In-built battery charger - - - -
Display 320x240 dots matrix, backlight 128x64 dots matrix, backlight 128x64 dots matrix, backlight Digital LCD, backlight LCD Dot matrix LCD, 160x240, backlight Custom LCD with backlight Custom LCD with backlight
Optical PASS / FAIL with LED - - - - - - -
WEIGHT 1320 g 1000 g 1310 g 1350 g 950 g 1350 g 1500 g 1002 g
SIZE (mm) 230x103x115 230x140x80 230x103x115 245x200x95 260x100x55 235x136x114 100x250x125 150x85x238
MAIN ACCESSORIES              
Tip commander Option Option - - Option
Plug commander Option Option - - - - -
Power supply adapter - - -
Rechargeable batteries - - Option
Standard current clamps - - Option - - - - Option
Low range current clamps - - Option - - - - -
Earth test set 20m Option Option Option - - Option Option
Earth test set 50m Option Option Option - - - - Option
Lux probe Option - Option - - - - Option