Call 01642 931329 for Orders & Advice

Amprobe ProInstall-75-UK MFT & EV-520-UK Test Adapter Kit

Amprobe ProInstall-75-UK MFT & EV-520-UK Test Adapter Kit
sku: 5050969

Free UK Delivery On Orders Over £40
  • Ideal for individuals requiring a method by which to test fixed wiring installations and UK EV charging stations
  • Sophisticated, small and safe multifunction installation tester
  • Test adapter kit facilitates the MFT’s ability to test UK EV charging stations 

RRP: £1,165.00
£932.00 Incl. VAT £1,118.40

Amprobe Spring Offer - Limited Time Only

RRP: £1,165.00
£932.00 Incl. VAT £1,118.40
Members earn 1864 points

Do you have a question or found it cheaper? Contact us

  • 30M R2 Extension Wander Test Lead (PVC Cable Reel)
    £29.99
  • Silvertronic 3 Wire Silicone Test Lead Set
    £21.95
  • UNI-T UT107 Multimeter & UT210B Clamp Meter Bundle
    £68.00
Description

Amprobe ProInstall-75-UK MFT & EV-520-UK Test Adapter Kit Details

Amprobe ProInstall-75-UK MFT with EV-520-UK Test Adapter Kit

*** Please note that this offer is available for a limited time only and is subject to availability or while stocks last. ***

The Amprobe ProInstall-75-UK MFT with EV-520-UK Test Adapter Kit includes the following products:

  • 1x Amprobe ProInstall-75-UK Multifunction Installation Tester
  • 1x Amprobe EV-520-UK Test Adapter Kit
  • 1x Test Lead Set
  • 1x Probe Tip Set
  • 1x Remote Test Probe
  • 1x Zero Adapter
  • 1x Fused Test probe Set with Instruction Sheet
  • 1x Mains Test Cord
  • 1x Carrying Strap
  • 1x User Manual on CD-ROM
  • 1x Quick Reference Card
  • 1x Calibration Certificate
  • 2x Set of 3 AA Batteries
  • 1x Soft Case

Please see the descriptions below for further information regarding Amprobe’s multifunction installation tester and test adapter kit.

Amprobe ProInstall-75-UK Multifunction Installation Tester Description

The Amprobe ProInstall-75-UK Multifunction Installation Tester is optimised for industrial, commercial and domestic environments. It can be used to test fixed wiring installations in these areas. As such it includes a comprehensive array of tests ensuring that it is able to verify the safety and functionality of electrical installations in accordance with IEC 60364, HD 384 requirements and BS7671 18th Edition wiring regulations.

The Amprobe ProInstall-75-UK Multifunction Installation Tester is able to check the following electrical parameters:

  • AC voltage and frequency
  • Wiring polarity
  • Insulation resistance
  • Continuity and resistance
  • Loop and line resistance
  • Prospective earth fault current (PEFC/IK)
  • Prospective short circuit current (PSC/IK)
  • RCD switching time
  • RCD tripping level (ramp test)

The Amprobe ProInstall-75-UK Multifunction Installation Tester also includes an advanced loop test that prevents RCDs from tripping, a fast high-current loop test, and selectable voltage measurements between L-N, L-PE and N-PE.

This instrument can be tailored to suit a variety of applications and, to this end, includes a number of insulation test voltages and a variable RCD current mode for customising the Amprobe ProInstall-75-UK Multifunction Installation Tester to suit various applications.

Measurements are indicated on the Amprobe ProInstall-75-UK Multifunction Installation Tester’s large display with a wide viewing angle. It is possible to view resistance measurements to a resolution of 0.01Ω. Additionally, the user is able to view mains voltage and frequency measurements simultaneously.

Furthermore, the Amprobe ProInstall-75-UK Multifunction Installation Tester will issue a PASS/ FAIL indication for the results of RCD tests, ensuring that the user can be certain of his/her readings.

Also adding to the certainty and, therefore, reliability and accuracy of the Amprobe ProInstall-75-UK Multifunction Installation Tester is the included zero adapter, which compensates for test leads, and the Auto-Null function, which subtracts test lead resistance from readings. Subtracted test lead resistance is stored in the Amprobe ProInstall-75-UK Multifunction Installation Tester’s memory even after it has been switched off.

In addition to a zero adapter, the Amprobe ProInstall-75-UK Multifunction Installation Tester is supplied with slim reach probes allowing the user to check installations in difficult-to-access areas. Furthermore, this instrument is supplied with a padded neck strap facilitating hands-free operation. The Amprobe ProInstall-75-UK Multifunction Installation Tester is compact, ergonomic and lightweight ensuring that it is easy to carry and therefore suitable for prolonged periods of testing.

The Amprobe ProInstall-75-UK Multifunction Installation Tester also features easy-to-operate controls allowing the user to select the required measurement function simply and swiftly. The user can select the required safety voltage level (50V or 25V) via this simple operating system, allowing him/her to tailor the Amprobe ProInstall-75-UK Multifunction Installation Tester to the environment.

In addition to selectable safety voltages, the Amprobe ProInstall-75-UK Multifunction Installation Tester includes a number of features designed to protect both the instrument and the user, including:

  • Auto Discharge function: quick and safe discharge of electrical energy in capacitive circuits
  • Live circuit detection: if the tester detects that the circuit is live it will halt testing
  • Wiring connection indication

The Amprobe ProInstall-75-UK Multifunction Installation Tester is a sophisticated, small and safe multifunction tester optimised for checking the safety of industrial, commercial and domestic fixed wiring electrical installations in accordance with local regulations.

Amprobe ProInstall-75-UK Multifunction Installation Tester Key Features

  • Optimised for commercial, industrial and domestic environments
  • Check the safety of fixed wiring installations in accordance with IEC 60364, HD 384 requirements and BS7671 18th Edition wiring regulations
  • Capable of testing a variety of electrical parameters
  • AC voltage and frequency
  • Wiring polarity
  • Insulation resistance
  • Continuity and resistance
  • Loop and line resistance
  • Prospective earth fault current (PEFC/IK)
  • Prospective short circuit current (PSC/IK)
  • RCD switching time
  • RCD tripping level (ramp test)
  • Advanced loop test that prevents RCDs from tripping
  • Fast high-current loop test
  • Selectable voltage measurements between L-N, L-PE and N-PE
  • Includes a number of insulation test voltages
  • Variable RCD current mode
  • Large display with a wide viewing angle
  • Indicates resistance to a resolution of 0.01Ω
  • View mains voltage and frequency simultaneously
  • PASS/ FAIL indication of RCD tests ensures certainty
  • Zero adapter compensates for test leads
  • Auto Null function subtracts test lead resistance from readings
  • Subtracted test lead resistance is saved to the tester’s memory even after it is switched off
  • Supplied with slim reach probes for accessing hard-to-reach areas
  • Supplied with a padded neck strap for hands-free operation
  • Compact, lightweight and ergonomic
  • Easy to carry
  • Ideal for prolonged periods of testing
  • Easy-to-operate controls
  • Selectable safety voltage: 25V or 50V
  • Auto Discharge function: quick and safe discharge of electrical energy in capacitive circuits
  • Live circuit detection: if the tester detects that the circuit is live it will halt testing
  • Wiring connection indication
  • Detachable test leads for easy replacement
  • A sophisticated, small and safe multifunction installation tester
  • Optimised for checking the safety of fixed wiring installations in accordance with local regulations

Amprobe EV-520-UK Test Adapter Kit Description

The Amprobe EV-520-UK Test Adapter Kit is optimised for use in the UK and as such includes the following equipment:

  • Amprobe EV-520-UK Test Adapter
  • EVC-20 Test Cable for EV Charging Station (type 2 with socket outlet or fixed cable for vehicle connector)
  • User Manual
  • Soft Carrying Bag

The Amprobe EV-520-UK Test Adapter Kit is optimised for checking the safety and functionality of UK electric vehicle charging stations (mode 3 for AC charging), as well as troubleshooting UK EV charging stations (mode 3 for AC charging). It can be used with Amprobe (and selected Fluke) multifunction installation testers and scope meters/ oscilloscopes in order to check and/or troubleshoot UK EV charging stations. To this end, it includes L1, L2, L3, N and PE measuring terminals which facilitate a connection to the user’s test instrument, such as the above Amprobe ProInstall-75-UK Multifunction Installation Tester.

The Amprobe EV-520-UK Test Adapter Kit is able to verify the safety and functionality of charging stations in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722 whilst simulating the presence of an electric vehicle.

This kit includes a type 2 EV connector and can be used to simulate CP error E and PE errors (earth fault). It is also capable of simulating various charging states using the Control Pilot (CP) State ‘Vehicle Simulation’ rotary switch. Moreover, the Amprobe EV-520-UK Test Adapter also includes a Proximity Pilot (PP) State ‘Cable Simulation’ rotary switch for mimicking the various current capabilities of charging cables.

Further to this, the Amprobe EV-520-UK Test Adapter includes a UK mains socket for checking the functionality and counting of an electric power meter via the connection of an external load. It also features CP terminals for checking the communication between the adapter (acting in the role of an electric vehicle) and the charging station.

In addition to these testing/ simulation capabilities, the Amprobe EV-520-UK Test Adapter also includes a PE Pre-test safety feature that can be used to test for the presence of dangerous voltage against earth. It also includes three LED lamps for separate phase indication allowing the user to identify the presence of voltage easily.

Finally, as the Amprobe EV-520-UK Test Adapter is optimised for verifying the safety and functionality of electric vehicle charging stations, which are often found outside, it features an IP54 protection rating, ensuring that it is protected against dust and water splashes.

The Amprobe EV-520-UK Test Adapter Kit is a comprehensive test kit that is ideal for expanding the capabilities and scope-for-use of the above Amprobe ProInstall-75-UK Multifunction Installation Tester.

Amprobe EV-520-UK Test Adapter Kit Key Features

  • Optimised for use in the UK
  • Includes: Amprobe EV-520-UK Test Adapter, EVC-20 Test Cable for EV Charging Station (type 2 with socket outlet or fixed cable for vehicle connector), User Manual & Soft Carrying Bag
  • Optimised for checking the safety and functionality of UK electric vehicle charging stations (mode 3 AC charging)
  • Can also be used to troubleshoot UK electric vehicle charging stations (mode 3 for AC charging)
  • Use with Amprobe (and selected Fluke) multifunction installation testers and scope meters/ oscilloscopes
  • Includes L1, L2, L3, N and PE measuring terminals which facilitate a connection to test instruments
  • Verify the safety and functionality of charging stations in accordance with IEC/ EN 61851-1 and IEC/HD 60364-7-722 whilst simulating the presence of an electric vehicle
  • Includes a type 2 EV connector
  • Simulate CP error E
  • Simulate PE error (earth fault)
  • Control Pilot (CP) State ‘Vehicle Simulation’ rotary switch for simulating various charging states
  • Proximity Pilot (PP) State ‘Cable Simulation’ rotary switch for mimicking the various current capabilities of charging cables
  • Connect an external load to the UK mains socket to check the functionality and counting of an electric power meter
  • CP terminals for checking the communication between the adapter (acting as an electric vehicle) and the charging station
  • PE Pre-Test safety feature for detecting the presence of dangerous voltage against earth
  • Three LED lamps for separate phase indications identifying the presence of voltage
  • IP54
  • A comprehensive kit ideal for expanding the capabilities and scope-for-use of the Amprobe ProInstall-75-UK Multifunction Installation Tester

What’s Included?

  • Amprobe ProInstall-75-UK Multifunction Installation Tester
  • Amprobe EV-520-UK Test Adapter Kit
  • 1x Test Lead Set
  • 1x Probe Tip Set
  • 1x Remote Test Probe
  • 1x Zero Adapter
  • 1x Fused Test probe Set with Instruction Sheet
  • 1x Mains Test Cord
  • 1x Carrying Strap
  • 1x User Manual on CD-ROM
  • 1x Quick Reference Card
  • 1x Calibration Certificate
  • 2x Set of 3 AA Batteries
  • 1x Soft Case
Technical Specs

Part Code: 5050969

Amprobe ProInstall-75-UK MFT & EV-520-UK Test Adapter Kit Technical Specifications

Please find below the technical specifications for the products included in this offer. 

Amprobe ProInstall-75-UK Multifunction Installation Tester Technical Specifications 

General Specifications
Size 10cm (L) x 25cm (W) x 12.5cm (H)
Weight (with Batteries) 1.3kg
Battery 6 x AA. Alkaline supplied. Usable with 1.2V NiCd or NiMH batteries (not included)
Battery Life (Typical) 200 hours idling
Fuse T3.15 A, 500 V, 1.5 kA 6.3 x 32 mm (PN 2030852)
Operating Temperature -10 to 40°C
Storage Temperature -10 to 60°C indefinitely (to -40°C for 100 hours)
Relative Humidity Non-condensing 80%: 10 to 35°C
70%: 35 to 40°C
Operating Altitude 0 to 2000m
Shock, Vibration Vibration to Class 3 per Mil-Prf-28800F 1 meter drop test, six sides, oak floor
Sealing IP40
EMC Complies with EN61326-1: 2006
Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ ISA
-s82.02.01 2000 and CAN/CSA c22.2 No.1010 2nd edition Overvoltage
Category III (CAT III), 500 V Measurement Category III is for
measurements performed in the building installation. CAT IV, 300V.
Examples are distribution panels, circuit breakers, wiring and cabling.
Performance EN61557-1, EN61557-2, EN61557-3, EN61557-4, EN61557-5,
EN61557-6, EN61557-7 Second edition. EN61557-10 First edition.
Maximum Voltage Between Any Terminal and Earth Ground 500V
Surge Protection 6 kV peak per EN 61010-1 Ed. 2.0 (2001-02)
AC Voltage Measurement (V)
Display Range Resolution Accuracy 50Hz to 60Hz Input Impedance Overload Protection
0 to 500V 0.1V 0.8% + 3 3.3MΩ 600V RMS
Continuity Testing (RLo)
Display Range (Autoranging) Resolution Open Circuit Voltage Accuracy Range RLo Test Current
0 to 20Ω 0.01Ω >4V ±(1.5% + 3 digits) 7.5 210mA
35 100mA
200Ω 0.1Ω >4V ±(1.5% + 3 digits) 240 20mA
2000Ω >4V ±(1.5% + 3 digits) 2000 2mA
Test Probe Zeroing Press the (zero) button to zero the test probe. Can subtract up to 2 Ω of lead resistance. Error message for >2 Ω.
Live Circuit Detection Inhibits test if terminal voltage >10 V ac detected prior to initiation of test.
Insulation Resistance Measurements (Riso)
Test Voltages 250, 500, 1000V
Accuracy of Test Voltage (At Rated Test Current) +10%, -0%
Test Voltage Insulation Resistance Range Resolution Test Current Accuracy
50V 10 kΩ to 50 MΩ 0.01 MΩ 1mA @ 50kΩ ±(3 % + 3 digits)
100V 100 kΩ to 20 MΩ 0.01 MΩ 1mA @ 100kΩ ±(3 % + 3 digits)
20 MΩ to 100 MΩ 0.1 MΩ ±(3 % + 3 digits)
250V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 250kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
500V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 500kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
200 MΩ to 500 MΩ 1 MΩ ±10%
1000V 100 kΩ to 200 MΩ 0.01 MΩ 1mA @ 1MΩ ±(1.5% + 3 digits)
200 MΩ to 1000 MΩ 1 MΩ ±10%
Auto Discharge Discharge time constant <0.5 second for C=1μF or less
Live Circuit Detection Inhibits test if terminal voltage >30V prior to initiation of test
Maximum Capacitive Load Operable with up to the 5μF load
Loop and Line Impedance (Zl), No Trip and Hi Current Modes RCD/FI
Mains Input Voltage Range 100 to 500V AC (50/60Hz)
Input Connection (Soft Key Selection) Loop Impedance: Phase to Earth
Line Impedance: Phase to Neutral
Limit on Consecutive Tests Automatic shutdown when internal components are too hot.
There is also a thermal shutdown for RCD tests
Maximum Test Current at 400V 20A sinusoidal for 10ms
Maximum Test Current at 230V 12A sinusoidal for 10ms
Range Resolution Accuracy
10Ω 0.001Ω Hi Current Ω: ±2% +15 digits)
20Ω 0.01Ω

No Trip Mode: ±3% + 6 digits

Hi Current Mode: ±(2% + 4 digits)

200Ω 0.1Ω No-Trip Mode: ±(3%)
Hi Current Mode: ±2%
2000Ω ±6%**
Notes * Valid for resistance of neutral circuit <20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
** Valid for mains voltage >200 V.
Prospective Earth Fault Current Test (PSCI/Ik)
Resolution and Units Resolution Units
IK < 1000A 1A
IK > 1000A 0.1kA
Computation Prospective Earth Fault Current (PEFC/IK) or Prospective Short Circuit Current (PSC/IK) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Range 0 to 10 kA or 0 to 50 kA (See Power-On Options earlier in this manual)
Accuracy Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing
Types Tested AC1, AC, A4, A, G2, S3, G, S
Test Signals  
AC The waveform is a sinewave starting at zero crossing, polarity determined by phase selection (0° phase starts with low to high zero
crossing, 180° phase starts with high to low zero crossing). The magnitude of the test current is IΔn x Multiplier for all tests.
A The waveform is a half wave rectified sinewave starting at zero, polarity determined by phase selection (0° phase starts with low to
high zero crossing,180° phase starts with high to low zero crossing). The magnitude of the test current is 2.0 x IΔn (rms) x Multiplier
for all tests for IΔn = 0.01A. The magnitude of the test current is 1.4 x IΔn (rms) x Multiplier for all tests for all other IΔn ratings.
B Smooth DC current according to EN61557-6 Annex A
Tripping Speed Test (ΔT)
Current settings** Multiplier Current Accuracy
10–30–100–300–500–1000 mA -VAR x 1/2 +0 %, -10 % of test current
10–30–100–300–500–1000 mA -VAR x 1 +10 %, -0 %
10–30–100 mA x 5 +10 %, -0 %
Note, 1 1000 mA type AC only. 700 mA maximum type A in VAR mode, not available for type B.
Current Multiplier *RCD type Measurement Range Trip Time Accuracy
Europe UK
x 1/2 G 310 ms 2000 ms ±(1 % Reading + 1 ms)
x 1/2 S 510 ms 2000 ms ±(1 % Reading + 1 ms)
x 1 G 310 ms 310 ms ±(1 % Reading + 1 ms)
x 1 S 510 ms 510 ms ±(1 % Reading + 1 ms)
x 5 G 50 ms 50 ms ±(1 % Reading + 1 ms)
x 5 S 160 ms 160 ms ±(1 % Reading + 1 ms)
Notes  *G – General, no delay
*S – Time delay
Maximum Trip Time
The RCD √ symbol switches on when testing the RCD trip time if the trip time meets the following conditions.
RCD I Δ N Trip Time Limits
AC G, A, B x 1 Less than 300 ms
AC, G - S type, A - S type, B - type x 1 Between 130 ms and 500 ms
AC G, A, B x 5 Less than 40 ms
AC, G - S type, A - S type, B - type x 5 Between 50 ms and 150 ms
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current Range Step Size Dwell Time Measurement Accuracy
Type G Type S
30 % to 110 % of RCD rated current1 10 % of IΔN 2 300 ms/step 500 ms/step ±5 %

Notes:

1 30 % to 150 % for Type A IΔN >10 mA

30 % to 210 % for Type A IΔN = 10 mA

20 % to 210 % for Type B

Specified trip current ranges (EN 61008-1):

50 % to 100 % for Type AC

35 % to 140 % for Type A (>10 mA)

35 % to 200 % for Type A (≤10 mA)

50 % to 200 % for Type B 2 5% for Type B

Phase Sequence Indication
Icon icon Phase Sequence indicator is active
Display of Phase Sequence Displays “1-2-3” in digital display field for correct sequence. Displays “3-2-1” for incorrect phase. Dashes in place of a number indicate a valid determination could not be made.
Mains Input Voltage Range (phase-tophase) 100 to 500 V

Amprobe EV-520-UK Test Adapter Kit Technical Specifications 

Functions
PE Pre-Test Yes, with touch electrode
PP simulation open, 13 A, 20 A, 32 A, 63 A
CP states A, B, C, D
CP Error “E” on/off
PE Error (Earth fault) on/off
Outputs (for test purpose only)
Measuring terminal L1, L2, L3, N and PE Max. 250/430 V, CAT II 300 V, max. 10 A
Mains socket Max. 250 V, CAT II 300 V, allowed current max. 10 A
CP Signal output terminals PWM communication protocol, approx. max. ±12 V
General Features
Input voltage Up to 250 V (single phase system) / up to 430 V (three phase system), 50/60 Hz, max 10 A
EV Connector (EVC-20) AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed cable with vehicle connector (type 2, 7P three-phase)
EV Connector (EVC-13) OPTIONAL AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase)
Mains outlet protection Fuse T 10 A/250 V, 5×20 mm
Dimensions (W × H × L) 110 × 45 × 220 mm (length without connection cable and connector)
Weight Approx. 1 kg (Adapter EVA-500-x + EC-connector EVC-20)
IP protection class IP54
CE directive Low Voltage Directive LVD 2014/35/EU
Safety

IEC/EN 61010-1:2010

IEC/EN 61010-2-030:2010

EMC Not applicable
Working temperature range 0 ... +40 °C
Storage temperature range -10 ... +50 °C
Reference humidity range 10 ... 60 % relative humidity w/o condensation
Working humidity range 10 ... 85 % relative humidity w/o condensation
Pollution degree 2
Protection class II
Measurement category CAT II 300 V
Altitude above sea level 2000 m max.
Reviews

We'd really appreciate it if you'd review this product

Why not leave a review of this product? Reviews help us improve our service for customers looking for a product to make a decision.

No reviews have been found

Write Your Own Review

How do you rate this product? Required *

 
1
2
3
4
5
Value
Quality
Price