This FLIR A400 Thermal Imaging Camera with a 24° lens and Wi-Fi connectivity is equipped with advanced smart sensor software and FLIR’s EBT software, making it suitable for screening individuals for possible elevated body temperature (EBT). It is NOT a diagnostic tool; however, it can be used for preliminary temperature screening to identify those with above-average skin temperature who may require further medical testing.
EBT can be indicative of a fever, a symptom of many illnesses. When the FLIR A400 Elevated Skin Temperature Screening Thermal Camera is used alongside medical procedures and equipment it can be used to help prevent the potential spread of infection.
The FLIR A400 Elevated Skin Temperature Screening Thermal Camera’s precise motorised focus ensures it is able to capture accurate temperature measurements throughout the FOV: the FLIR A400 Elevated Skin Temperature Screening Thermal Camera has an accuracy of ±2°C. To maintain and improve accuracy the FLIR A400 Elevated Body Temperature Screening Thermal Camera includes an External Black-Body Correction function.
Additionally, advanced smart sensor configuration equips the camera with sophisticated thermal imaging as well as edge computing and an Industrial Internet of Things (IIOT). The FLIR A400 Elevated Skin Temperature Screening Thermal Camera can capture high-quality thermal images with a resolution of 320 x 240px. It also includes a range of analysis tools such as spotmeters, boxes, deltas, isotherms, iso-coverage, and hot/ cold detection. Analysis features, such as the Polygon Line function, can be used to increase definition in areas of interest and improve object analysis.
Similarly, the FLIR A400 Elevated Skin Temperature Screening Thermal Camera’s FSX® (Flexible Scene Enhancement) technology enhances detail in low light and increases the contrast in even-temperature scenes. Additionally, it includes options for adjusting temperature measurements and alarms in relation to a reference temperature source.
Thermal footage and data can be shared via Wi-Fi using the FLIR A400 Elevated Skin Temperature Screening Thermal Camera’s compressed radiometric streaming which reduces the bandwidth by 90%. In addition to enabling the sharing of data, compressed radiometric streaming also allows multiple cameras to be connected.
Furthermore, superior connectivity and built-in computing options mean the FLIR A400 Elevated Skin Temperature Screening Thermal Camera can be integrated into a variety of new and existing networks. It includes support for Modbus TCP and Ethernet/IP which enable easy integration into HMI/ SCADA systems. It provides superior I/O control over Modbus TCP Master, enabling integration with industrial automation systems using analogue and digital controls.
Additionally, the FLIR A400 Elevated Skin Temperature Screening Thermal Camera can be easily integrated into web services with the REST API over XML or JSON.
The FLIR A400 Elevated Skin Temperature Screening Thermal Camera is a precise, powerful and flexible thermal monitoring system suitable for EBT screening.
FLIR A400 Elevated Skin Temperature Screening Thermal Camera Key Features
- A400 Thermal Camera with a 24° lens, Wi-Fi, advanced smart sensor software and EBT software
- Optimised for screening individuals for possible EBT
- Please note this camera is not a diagnostic tool
- Use alongside medical equipment and procedures to help prevent the potential spread of infection
- Precise motorised focus
- Capture accurate measurements throughout the FOV
- Accuracy: ±2°C
- External Black-Body Correction function improves accuracy
- Edge computing
- Industrial Internet of Things (IIoT)
- Advanced thermal imaging
- IR resolution: 320 x 240px
- Analysis tools: spotmeters, boxes, deltas, isotherms, iso-coverage and hot/cold detection
- Polygon Line function: increase definition in areas of interest and improve object analysis
- FSX® technology: enhance detail in low light and increase contrast in even-temperature scenes
- Adjust temperature measurements and alarms in relation to a reference temperature source
- Share footage and data via Wi-Fi
- Compressed radiometric streaming: reduces bandwidth by 90%
- Compressed radiometric streaming allows data to be shared via Wi-Fi
- Compressed radiometric streaming allows multiple cameras to be connected
- Superior connectivity
- Integrated computing options
- Can be integrated into new and existing networks
- Supports Modbus TCP and Ethernet/IP for easy integration into HMI/ SCADA systems
- Superior I/O control over Modbus TCP Master enables integration with industrial automation systems using analogue and digital controls.
- Easily integrated into web services with the REST API over XML or JSON
- Prepares for digitalisation through MQTT
- A precise, powerful and flexible thermal monitoring system suitable for EBT screening
FLIR Axxx (T300216) Accessory Kit
A FLIR Axxx Accessory Kit is included with the FLIR A400 Elevated Skin Temperature Screening Thermal Camera. The FLIR Axxx Accessory Kit consists of the following:
- Antenna for WLAN - 2.4/5 GHz
- 2m (6.6ft) M12 to Pigtail Cable
- 2m (6.6ft) M12 to RJ45 Ethernet Cable
- 2m (6.6ft) CAT-6 Ethernet Cable
- Two-ball Joint Mounting Bracket Kit
- Gigabit PoE Injector - 15W
What’s Included?
- FLIR A400 Thermal Camera
- 24° Lens
- Integrated Advanced Smart Sensor Software
- Integrated FLIR EBT Software
- Integrated Wi-Fi
- Cabling
- PoE Switch
- FLIR Axxx (T300216) Accessory Kit
FLIR A400 Elevated Skin Temperature Screening Thermal Camera Technical Specifications
Image and Optical Data | Advanced Config. |
IR resolution | 320 × 240 (A400) |
Visual resolution* | 1280 × 960 |
Thermal resolution | <30 mK to <50 mK, lens dependent |
Lens | 24° |
IR Camera Focus | One-shot contrast, motorized, manual |
Measurement | |
Object temperatures | -20°C to 2000°C (-4°F to 3632°F), 3 ranges |
Accuracy | ±2°C (±3.6°F) or ±2% of reading |
Measurement analysis | |
Standard functions | 10 spotmeters, 10 boxes & mask polygons, 3 Deltas, 2 isotherm, 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline |
Automatic hot/cold detection |
Max./min. temperature value and position shown within box |
Scheduled response | sftp (image), SMTP (image and/or measurement data/result) |
Measurement frequency | Up to 10 Hz |
Measurement result read-out |
Yes; common protocols include Ethernet/IP, Modbus TCP, MQTT, and REST API |
Alarm | |
Alarm function | On any selected measurement function; digital in; internal camera temperature |
Alarm output | Yes: common output includes e-mail, EtherNet/IP, Modbus TCP, and RESTful AP |
Video Streaming, RTSP Protocol | |
Unicast | Yes |
Multicast | Yes |
Multiple image streams | Yes |
Video stream 0 | |
Source | Visual, IR, MSX® |
Contrast enhancement | FSX®, histogram equalization (IR only) |
Overlay | With, without |
Pixel format | YUV411 |
Encoding | H.264/MPEG4/MJPEG |
Video stream 1 | |
Source | Visual |
Overlay | No |
Pixel format | YUV411 |
Encoding | H.264/MPEG4/MJPEG |
Radiometric streaming, RTSP | |
Source | IR |
Pixel format | MONO 16 |
Encoding | Compressed JPEG-LS; FLIR radiometric |
Ethernet | |
Interface | Wired; Wi-Fi |
Connector types | M12 8-pin X-coded, female; RP-SMA, female |
Ethernet type & standard |
1000 Mbps, IEEE 802.3 |
Ethernet power | Power over Ethernet, PoE IEEE 802.3af class 3 |
Ethernet protocols | Include EtherNet/IP, Modbus TCP, and MQTT |
Digital input/output | |
Connector type | M12 Male 12-pin A-coded (shared with ext. power) |
Digital input | 2× opto-isolated, Vin (low) = 0-1.5 V, Vin (high) = 3-25 V |
Digital output | 3× opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1× dedicated as fault output (NC) |
Power system | |
Connector type | M12 Male 12-pin A-coded (shared with Digital I/O) |
Power consumption | 7.5 W at 24 V DC typical; 7.8 W at 48 V DC typical; 8.1 W at 48 V PoE typical |
Wi-Fi | |
Connector type | Female RP-SMA |