Call 01642 931329 for Orders & Advice

Fluke 1664 FC Multifunction Tester & FREE T6-1000 Tester & DMS Software

Fluke 1664 FC Multifunction Tester & FREE T6-1000 Tester & DMS Software
sku: 5051123
MPN: 5051123

Free UK Delivery On Orders Over £40
  • Includes a comprehensive, compact and convenient, Fluke Connect® enabled multifunction tester
  • Perform non-contact frequency, and true-RMS AC voltage and current measurements using the T6-1000
  • Manage, analyse, and export data, as well as create reports using the Fluke DMS Software

Was: £1,345.00
You Save: £545.00
£800.00 Incl. VAT £960.00

Fluke Spring Offer - FREE T6-1000 Tester & DMS Software

Was: £1,345.00
You Save: £545.00
£800.00 Incl. VAT £960.00
Under 10 In Stock
Members earn 1600 points

Do you have a question or found it cheaper? Contact us

Description

Fluke 1664 FC Multifunction Tester & FREE T6-1000 Tester & DMS Software Details

Fluke 1664FC Multifunction Tester & FREE T6-1000 Tester & DMS Software

*** Please note that this offer is available for a limited time only and is subject to availability or while stocks last. ***

The Fluke 1664 Multifunction Tester with FREE Fluke T6-1000 Electrical Tester & FREE Fluke DMS Software is a promotional offer including the following products:

  • Fluke 1664 FC Multifunction Installation Tester with Standard Accessories
  • FREE Fluke T6-1000 FieldSense Electrical Tester with Standard Accessories
  • FREE Fluke DMS Software

For further information regarding the products below, please see the following descriptions.

Fluke 1664 FC Multifunction Installation Tester Descriptions

The Fluke 1664 FC Multifunction Installation Tester features a vast array of measuring capabilities making it suitable for installation professionals requiring a comprehensive and easy-to-use tool for troubleshooting and verifying electrical installations.

The Fluke 1664 FC Multifunction Installation Tester is the upgraded version of the 1663 Multifunction Installation Tester and as such shares a number of its measurement and testing capabilities:

  • Insulation resistance
  • Loop resistance
  • Line resistance
  • Earth resistance
  • Continuity test
  • 10mA continuity test for measuring motor windings
  • RCD variable current
  • Ramp test for measuring RCD switching time and tripping level
  • A combined test for RCD Type A & AC trip times and currents
  • Type B/ B+ (smooth DC sensitive) RCD tests
  • Wiring polarity check to detect broken N and PE wires
  • True-RMS AC/DC voltage
  • Frequency
  • Prospective earth fault current (PEFC/IK)
  • Prospective short-circuit current (PSC/IK)
  • Phase Sequence (with phase sequence indicator)

In addition to the above measurement capabilities, this instrument includes a number of new measurement and test features that are unique to the Fluke 1664 FC Multifunction Installation Tester, including:

  • NEW Installation Pre-Test™ safety function – optimised for protecting peripheral equipment mistakenly connected to the system-under-test; this safety function will stop the insulation test and alert the user via a visual indication if it has detected a connected appliance
  • NEW insulation tests at L-N, L-PE and N-PE inputs
  • NEW continuity tests at L-N, L-PE and N-PE inputs (also present on the 1663 MFT)
  • NEW Auto Test function – this function performs five installation tests in one sequence; the user may opt to include type A and AC RCD tests in the Auto Test sequence; this feature makes testing simpler, faster, more accurate and less cumbersome as the number of manual connections required is reduced
  • NEW loop and line resistance with an mΩ resolution

As the Fluke 1664 FC Multifunction Installation Tester is also Fluke Connect® enabled (another feature that is unique to this model), results from the above tests may be sent to a smartphone or tablet (with the Fluke Connect® app downloaded) or can be saved to the Fluke Cloud™. It is also possible to communicate results to relevant persons via email or video call using Fluke Connect’s ShareLive feature. This allows collaborative decisions to be made without the installation professional having to leave the field.

Furthermore, data saved to the Fluke Cloud™ can be accessed as required regardless of location. Measurements saved to the Fluke Cloud™ are subject to world-class data protection and can be imported into Fluke’s Data Management Software (see below) for further analysis and/or to create certificates. For a quick overview of the Fluke Connect® App, please see the following video. 

Measurements may also be saved to the Fluke 1664 FC Multifunction Installation Tester’s three-tier memory. This extensive memory and the Fluke 1664 FC Multifunction Installation Tester’s comprehensive measurement capabilities ensure that it is able to inspect and test electrical installations in accordance with a variety of local regulations.

This instrument also features a Z-max memory for loop tests allowing the user to access and evaluate the highest loop test result. In addition to this, the Fluke 1664 FC Multifunction Installation Tester includes a number of features designed to aid with the simplicity, accuracy and comprehensiveness of performing loop tests. These include:

  • High-current Loop mode for faster measurements than loop tests with a non-trip mode for RCDs
  • PEFC/ PSC and loop impedance are measured in parallel and displayed simultaneously on the tester’s dual display

This instrument is also capable of measuring RCD trip current and trip time simultaneously (types AC and A). Moreover, the Fluke 1664 FC Multifunction Installation Tester can perform fast voltage measurements between L-N, L-PE and N-PE via the mains cord removing the need to change measurement connections. The Fluke 1664FC’s ring testing function also adds to the convenience of this tester, as required input sockets can be selected via the soft keys removing the need to continually swap test leads.

Nominal resistance present in test leads and mains cords is compensated for by the Fluke 1664 FC Multifunction Installation Tester’s zero adapter. This feature adds to the accuracy of the Fluke 1664 FC Multifunction Installation Tester, whereas its 50V Earth Volt Touchpad protects the user from potentially dangerous situations by detecting raised earth voltages above 50V.

Measurements are indicated on the Fluke 1664 FC Multifunction Installation Tester’s large, backlit display with a wide viewing angle and clear symbols. The wide display and rotary dial, designed for selecting the required measurement function, also add to this tester’s ease- and simplicity-of-operation. 

Finally, the Fluke 1664 FC Multifunction Installation Tester is both compact and lightweight and is supplied with a neck strap enabling hands-free usage.

The Fluke 1664 FC Multifunction Installation Tester is a comprehensive, compact and convenient Fluke Connect® enabled multifunction installation tester. It is the ideal tool for professional installation technicians.

Fluke 1664 FC Multifunction Installation Tester Key Features

  • Features a vast array of measurement capabilities
  • Suitable for installation professionals requiring a comprehensive and easy-to-use tool for troubleshooting and verifying electrical installations
  • An upgraded version of the 1663 MFT
  • Features an array of measurement and testing capabilities
  • Insulation resistance
  • Loop resistance
  • Line resistance
  • Earth resistance
  • Continuity test
  • 10mA continuity test for measuring motor windings
  • RCD variable current
  • Ramp test for measuring RCD switching time and tripping level
  • A combined test for RCD Type A & AC trip times and currents
  • Type B/ B+ (smooth DC sensitive) RCD tests
  • Wiring polarity check to detect broken N and PE wires
  • True-RMS AC/DC voltage
  • Frequency
  • Prospective earth fault current (PEFC/IK)
  • Prospective short-circuit current (PSC/IK)
  • Phase Sequence (with phase sequence indicator)
  • Includes a number of new tests and features
  • NEW Installation Pre-Test™ safety function – optimised for protecting peripheral equipment mistakenly connected to the system-under-test
  • NEW insulation tests at L-N, L-PE and N-PE inputs
  • NEW continuity tests at L-N, L-PE and N-PE inputs (also present on the 1663 MFT)
  • NEW Auto Test function – this function performs five installation tests in one sequence; the user may opt to include type A and AC RCD tests in the Auto Test sequence
  • NEW loop and line resistance with an mΩ resolution
  • Fluke Connect® enabled
  • Test results can be sent to the user’s smartphone or tablet (with Fluke Connect® downloaded)
  • Send results via email
  • Communicate with relevant persons via the Fluke Connect’s ShareLive video call feature
  • Facilitates collaborative decision making without the user having to leave the field
  • Test results can be saved to the Fluke Cloud™ using Fluke Connect®
  • Measurements saved to the Fluke Cloud™ can be accessed at any time from anywhere
  • Information saved to the Fluke Cloud™ is subject to world-class data protection
  • Readings can be downloaded to Fluke’s DMS Software from the Fluke Cloud™
  • Save measurements to the tester’s three-tier memory
  • Inspect and test electrical installations in accordance with a variety of local regulations
  • Z-max memory for loop test measurements allows the user to access and analyse the highest result
  • High-current Loop mode for faster measurements than loop tests with a non-trip mode for RCDs
  • PEFC/ PSC and loop impedance are measured in parallel and displayed simultaneously on the tester’s dual display
  • Measure RCD trip time and trip current simultaneously (types AC and A)
  • Fast voltage measurements between L-N, L-PE and N-PE via mains cord
  • Ring test function allows the user to select the relevant input socket via soft keys removing the need to continually swap test leads
  • Zero adapter for compensating for resistance present in test leads
  • 50V Earth Volt TouchPad protects the user from potentially dangerous situations by detecting raised earth voltages above 50V
  • Large, backlit display with a wide viewing angle and clear symbols
  • Rotary dial for selecting the required measurement function
  • Simple-, safe- and easy-to-use
  • Compact and lightweight
  • Supplied with a padded neck strap for handsfree usage
  • Supplied with 6x AA (IEC LR6) cell batteries, hard carrying case, a zero adapter, a heavy-duty mains cord, standard test lead set, quick reference guide, TPI65X remote control probe and lead and a user manual on CD-ROM
  • A comprehensive, compact, convenient, Fluke Connect® enabled multifunction installation tester
  • Ideal for professional installation technicians

FREE Fluke T6-1000 Electrical Tester with FieldSense Technology Description

The Fluke T6-1000 Electrical Tester with FieldSense Technology is supplied for free with the Fluke 1664 FC Multifunction Installation Tester. It is able to conduct true-RMS, non-contact* voltage, current and frequency measurements of wires up to AWG 4/0 (120 mm²) carrying a maximum current of 200A. Please see the following video for a quick introduction to the T6-1000 Electrical Tester. 

The Fluke T6-1000 Electrical Tester’s FieldSense technology facilitates the non-contact, true-RMS measurement of AC voltage and current, as well as frequency, via its 17.8mm jaw.* The Fluke T6-1000 Electrical Tester features the following measurement ranges:

  • True-RMS AC current: 0.1 to 200 A
  • True-RMS AC voltage: 1 to 1000 V
  • Frequency: 45 to 66 Hz

Current and voltage measurements are displayed simultaneously on the Fluke T6-1000 Electrical Tester’s easy-to-read, backlit display. This increases the efficiency with which electrical systems can be tested. Measurements may be frozen on the display using the HOLD button allowing the operator to record readings at his/her convenience.

In addition to measuring frequency, AC current and voltage via the Fluke T6-1000 Electrical Tester’s jaw, this instrument can also be used with test leads to perform AC voltage measurements (to 1000V), DC voltage measurements (to 1000 V) and resistance measurements (between 1Ω and 100kΩ).

The Fluke T6-1000 Electrical Tester with FieldSense technology improves the efficiency and ease with which electrical systems may be checked. It’s non-contact measurement capabilities, facilitated by its FieldSense technology, means that the user does not need to open covers or remove wire nuts to perform true-RMS AC voltage, true-RMS AC current and frequency measurements.

Fluke T6-1000 Electrical Tester with FieldSense Technology Key Features

  • Free item with the Fluke 1664 FC Multifunction Installation Tester
  • Conduct true-RMS, non-contact* voltage, current and frequency measurements
  • Can be used to check wires up to AWG 4/0 (120 mm²) carrying a maximum current of 200A
  • FieldSense technology facilitates non-contact*, true-RMS measurements of AC voltage and current, as well as frequency
  • 17.8mm jaw
  • True-RMS AC current: 0.1 to 200 A
  • True-RMS AC voltage: 1 to 1000 V
  • Frequency: 45 to 66 Hz
  • Current and voltage measurements are displayed simultaneously
  • Easy-to-read, backlit display
  • Freeze measurements on the display using the HOLD button
  • Can be used with test leads to measure AC voltage (to 1000 V), DC voltage (to 1000 V) and resistance (1Ω - 100kΩ)
  • Compatible with Fluke’s TPAK Magnetic Meter Hanger (OPTIONAL)
  • Supplied with user documentation and attached test leads with 4mm probe caps
  • Includes a 2-year warranty from Fluke**
  • Increases the efficiency and improves the ease with which electrical systems can be tested
  • No need to open covers, or remove wire nuts to perform AC voltage, AC current and frequency measurements

*Requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.

** May be extended to four years following registration of the tester with Fluke within 45 days of purchase: http://a.fluke.com/registration

FREE Fluke DMS Software Description

Like the Fluke T6-1000 Electrical Tester, the Fluke DMS Software is included at no extra cost with the Fluke 1664 FC Multifunction Installation Tester.

Measurements saved to the Fluke 1664 FC Multifunction Installation Tester and/or the Fluke Cloud™ may be downloaded to this software for further analysis. Downloaded data can also be used to create relevant reports, certificates and documentation that can be exported via email to colleagues and clients. The Fluke DMS Software is able to create reports in accordance with a variety of local regulations.

This easy-to-navigate software program can be configured to display menus in one of the four available languages: English, French, German or Dutch.

The Fluke DMS Software is ideal for creating reports and managing, analysing and exporting the measurements acquired by the Fluke 1664 FC Multifunction Tester.

Fluke DMS Software Key Features

  • Supplied for free with the Fluke 1664FC Multifunction Installation Tester
  • Measurements saved to the Fluke 1664 FC or to the Fluke Cloud™ may be downloaded to the software
  • Analyse, organise and export downloaded measurements
  • Use data to create relevant reports, certificates and documentation
  • Send reports to clients or colleagues via email
  • Capable of creating reports in accordance with a variety of local regulations
  • Easy-to-navigate
  • Display menus in English, French, German and Dutch
  • Ideal for creating reports and managing, analysing and exporting data

What’s Included?

  • Fluke 1664 FC Multifunction Installation Tester with Standard Accessories
  • FREE Fluke T6-1000 FieldSense Electrical Tester with Standard Accessories
  • FREE Fluke DMS Software
Technical Specs

Part Code: 5051123

Fluke 1664FC Multifunction Tester & FREE T6-1000 Tester & DMS Software Technical Specifications 

Please find below the technical specifications for the items included in this promotion. 

Fluke 1664 FC UK Multifunction Installation Tester Technical Specifications

AC Voltage Measurement
Range 500 V
Resolution 0.1 V
Accuracy 45 Hz- 66Hz 0.8% + 3
Input Impedance 360 kΩ
Overload Protection 660 V rms
Continuity Testing (RLO)
Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Open Circuit Voltage >4 V
Insulation Resistance Measurement (RISO)
Test Voltages 50-100-250-500-1000 V
Accuracy of tTest Voltage (as rated test current) +10%, -0%
Test Voltage 50 V
100 V
250 V
500 V
1000 V
Insulation Resistance Range 20 MΩ /50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ
Resolution 0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
Test Current 1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ
Loop and Line Impedance (ZI)
Range  10 Ω / 0.001 Ω / High current mΩ mode
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Prospective Earth Fault Current, PSC Test
Range 1000 A / 10 kA (50 kA)
Resolution 1 A / 0.1 kA
Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD Testing, RCD Types Tested
RCD Type AC¹
G², S³
Model 1664 A, AC, B5, S
Notes ¹Responds to AC 
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal
Tripping Speed Test (ΔT)
Current settings¹ 10-30-100-300-500-1000 mA – VAR
10-30-100 mA
Multiplier x ½, x 1
x 5
Measurement Range

RCD Type G: 310 ms

                       50 ms

RCD TYpe S: 510 ms

                       160 ms

Notes ¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current Range 30% to 110% of RCD rated current¹
Step Size 10% of IΔN²
Dwell Time

Type G: 300 ms/step

Type S: 500 ms/step

Measurement Accuracy ±5%
Specified Trip Current Ranges (EN 61008-1) 50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B
Notes ¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B
Earth Resistance Test (RE)
Range 200 Ω / 2000 Ω
Resolution 0.1 Ω / 1Ω
Frequency  128 Hz
Output Voltage 25 V
Phase Sequence Indication
Icon Phase Sequence indicator is active
General Specifications
Size (L x W x H) 10 x 25 x 12.5 cm
Weight (including batteries) 1.3 Kg
Battery Size, quantity Type AA, 6 ea
Safety  Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
Sealing IP-40
Overvoltage CAT III / 500V; CAT IV 300V
Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Fluke T6-1000 Electrical Tester with FieldSense Technology Technical Specifications

Measurement Specifications 

Function Requires Test Leads?

T6-1000

Range

Resolution Accuracy
FieldSense AC Voltage No 1-1000V 1V ±(3 % + 3 counts) [2] [3] 45 Hz - 66 Hz
FieldSense AC Current  No 0.1-200A 0.1A ±(3 % + 3 counts) 45 Hz - 66 Hz
FieldSense Frequency (Hz) No 45-66 Hz 1Hz ±(1 % + 2 counts) [3]
Volts AC Yes 1-1000V 1V ±(1.5 % + 2 counts) 45 Hz - 66 Hz
Volts DC  Yes 1-1000V 1V ±(1 % + 2 counts)
Resistance 

Yes

Yes

Yes

2000 Ω

20.00 kΩ

100.0 kΩ

1 Ω

0.01 kΩ

0.1 kΩ

±(1 % + 2 counts)

±(1 % + 2 counts)

±(1 % + 2 counts)

Safety (measurement category)   1000 V CAT III 600 V CAT IV    
Notes Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

General Specifications     

Calibration 1-year calibration cycle   
Dimensions  61.1 mm x 259.3 mm x 43.8 mm    
Operating Temperature  -10 °C to +50 °C (14 °F to 122 °F)
Storage Temperature  -30 °C to +60 °C (-22 °F to +140 °F)
Operating Altitude  2,000 m (6,562 feet)     
Storage Altitude  10,000 m (32,808 feet)     
Relative Humidity 

0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)

0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)

0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)    

Battery Type and Life  2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense     
Temperature Coefficient   0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)    
Safety  IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2     
Electromagnetic Environment  IEC/EN 61326-1: Portable   
Fork Opening   17.8mm 
Weight  0.35 kg (0.78 lb)    

Fluke DMS Software Technical Specifications 

Processor Pentium® 4 or higher with support of all customary operating systems
Operating System Microsoft Windows® XP, Windows® 7, Windows® 8, Windows® 8.1, and Windows® 10
Memory 256 MB RAM
Hard Drive Memory 400 MB
Monitor Super VGA (800 x 600)
Drive CD-ROM/DVD
Input Device Mouse or compatible
Interface RS-232 for data transmission. USB by means of optional adapter cable (USB - RS-232).
Reviews

We'd really appreciate it if you'd review this product

Why not leave a review of this product? Reviews help us improve our service for customers looking for a product to make a decision.

No reviews have been found

Write Your Own Review

How do you rate this product? Required *

 
1
2
3
4
5
Quality
Price
Value