The Fluke 6531-XXX Electronic Hydraulic Deadweight Tester can be used to calibrate pressure sensing instruments such as transducers, transmitters, analogue gauges, sensors and other pressure calibrators. It is available in seven models with varying pressure ranges. Please see the table below for further details.

Product Code Product Name  Pressure Ranges
6531-7M Fluke 6531-7M Electronic Hydraulic Deadweight Tester - 7MPa (1K psi) 0.7 to 7 MPa, 100 to 1,000 psi
6531-14M Fluke 6531-14M Electronic Hydraulic Deadweight Tester - 14MPa (2K psi) 1.4 to 14 MPa, 200 to 2,000 psi
6531-20M Fluke 6531-20M Electronic Hydraulic Deadweight Tester - 20MPa (3K psi) 2 to 20 MPa, 300 to 3,000 psi
6531-40M Fluke 6531-40M Electronic Hydraulic Deadweight Tester - 40MPa (6K psi) 4 to 40 MPa, 600 to 6,000 psi
6531-70M Fluke 6531-70M Electronic Hydraulic Deadweight Tester - 70MPa (10K psi) 7 to 70 MPa, 1,000 to 10,000 psi
6531-140M Fluke 6531-140M Electronic Hydraulic Deadweight Tester - 140MPa (20K psi) 14 to 140 MPa, 2,000 to 20,000 psi
6531-200M-B Fluke 6531-200M-B Electronic Hydraulic Deadweight Tester - 200MPa (20K psi) 20 to 200 MPa, 6,000 to 30,000 psi

This electronic, hydraulic deadweight tester can be used with a variety of fluids including Sebacate calibration fluid, mineral oil and water. It has been designed to improve the accuracy, practicality and versatility of traditional piston and cylinder deadweight testers. For instance:

  • Weight masses are not required
  • The pressure value can be read in real-time with no need to account for variables such as gravity and temperature
  • Piston and cylinder assemblies do not require changing
  • Not susceptible to significant errors caused by vibrations
  • Minimal pressure increments are not limited by the smallest masses available, making the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester suitable for calibrating analogue pressure gauges as precise nominal pressure values can be set, tested and measured
  • Can be used to perform checks in a variety of measurement units

Additionally, this instrument has a total one-year measurement uncertainty of ±0.02% (±0.025% for two years) which is in keeping with many traditional deadweight testers.  

Further to this, the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester includes a single quartz reference pressure transducer which offers a percentage of reading performance from 10% to 100% of device full scale.

The Fluke 6531-XXX Electronic Hydraulic Deadweight Tester also includes a number of features and functions designed to improve the efficiency of calibration, as well as protect the condition of the device-under-investigation. To this end, it includes an AutoTest function which allows the user to program tests for the electronic deadweight tester to perform automatically; the AutoRange feature can be used to tailor the measurement and safety features to the instrument-under-investigation, and the over-pressure alarm also works to improve the safety of this tester and reduce the possibility of calibration errors and/or damage to attached instruments.  

Furthermore, the Ready/ Not Ready indicator informs the user as to when it is appropriate to take measurements, again adding to the accuracy and ease-of-use of this tester. Measurements acquired by the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester can be saved to its internal memory. The RS-232 remote interface can be used to communicate data to the user’s PC with Fluke’s COMPASS Pressure Software (NOT included), allowing the user to view data in real-time and create reports.

In addition to this, the RS-232 interface can be used to operate the reference pressure monitor, in the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester, from a computer via ASCII character command strings. Alternatively, this module can be configured via the tester’s front panel display, keyboard and/or OPTIONAL foot pedal. The OPTIONAL foot pedal also facilitates hands-free data collection when the tester is running AutoTests.

Using this instrument it is easy to generate the hydraulic pressure necessary; via the low torque variable volume, the user can create, and make fine adjustments to, hydraulic pressures up to 200MPa. This simple-to-use system requires minimal physical effort. Moreover, the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester includes an integrated priming system which facilitates the user’s ability to fill the tester with the required fluid and purge it of unwanted air, ensuring that all hydraulic pressures are generated accurately. A vacuum fill kit is also included with this tester allowing the user to fill the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester with the fluid of his/her choice.

Further to this, the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester is supplied with a selection of tests station adapters, including 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5, ensuring that instruments-under-investigation can be attached easily and without PTFE tape and/or wrenches. Also adding to this instrument’s practicality is its ability to be powered using a rechargeable battery pack (NOT included), making it suitable for use in a variety of environments.

The Fluke 6531-XXX Electronic Hydraulic Deadweight Tester is a rugged, lightweight, comprehensive calibrator ideal for applications in metrology and calibration labs, as well as on production floors and in the field.

Fluke 6531-XXX Electronic Hydraulic Deadweight Tester Key Features

  • Ideal for calibrating pressure sensing instruments such as transducers, transmitters, analogue gauges, sensors and other pressure calibrators
  • Available in seven models with varying pressure ranges
  • Can be used with a variety of fluids including Sebacate calibration fluid, mineral oil and water
  • A sophisticated alternative to traditional deadweight testers
  • Weight masses are not required
  • The pressure value can be read in real-time with no need to account for variables such as gravity and temperature
  • Piston and cylinder assemblies do not require changing
  • Not susceptible to significant errors caused by vibrations
  • Minimal pressure increments are not limited by the smallest masses available, making the Fluke 6531-XXX Electronic Hydraulic Deadweight Tester suitable for calibrating analogue pressure gauges as precise nominal pressure values can be set, tested and measured.
  • Can be used to perform checks in a variety of measurement units
  • One-year measurement uncertainty of ±0.02% (two-year = ±0.025%)
  • Includes a single quartz reference pressure transducer which offers a percentage of reading performance from 10% to 100% of device full scale.
  • AutoTest function
  • AutoRange function
  • Over-pressure alarm
  • Ready/ Not Ready indicator
  • Measurements can be saved to the onboard memory
  • RS-232 remote interface can be used to communicate data to the user’s PC with Fluke’s COMPASS Pressure Software (NOT included)
  • RS-232 can be used to operate the reference pressure monitor remotely using a computer and ASCII character strings
  • Reference pressure monitor can also be configured using the front panel display, keyboard and/or OPTIONAL foot pedal
  • OPTIONAL foot pedal facilitates hands-free data collection when the tester is running AutoTests
  • Generate and make adjustments to hydraulic pressure using the low torque variable volume
  • Create pressures up to 200MPa
  • The physical effort required to make hydraulic pressure is minimal
  • Integrated priming system for purging the tester of air and filling it with the required fluid
  • Vacuum fill kit included with this tester
  • Supplied with a selection of test adapters
  • PTFE tape and/or wrenches are not required to attach instruments-under-investigation
  • Can be operated using a rechargeable battery pack (NOT included)
  • Rugged, lightweight, comprehensive calibrator ideal for applications in metrology and calibration labs, as well as on production floors and in the field

What’s Included?

  • Your Choice of Fluke 6531-XXX Electronic Hydraulic Deadweight Tester
  • Power Supply
  • Operating Manual
  • Vacuum Liquid Fill Kit
  • Test Station Mount Fitting
  • NPT adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
  • BSP adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
  • Metric adapters: M20 x 1.5 and M14 x 1.5

Fluke 6531-XXX Electronic Hydraulic Deadweight Tester Technical Specifications 

General Specifications 
Power Requirements
To RPM4-E-DWT 12 V dc 1.2 A
To AC to DC power supply 100 V ac to 240 V ac, 50/60 Hz
Temperature Range
Storage - 20 °C to 70 °C
Operating 10 °C to 40 °C
Relative Humidity 
Storage 0 % to 100 %
Operating 0 % to 70 %
Weight
1 Q-RPT 12 kg (26 lb) approximate
2 Q-RPT 14 kg (30 lb) approximate
Dimensions
E-DWT footprint 41.4 cm W x 37.1 cm D (16.3 in x 14.6 in)
E-DWT height 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height
Pressure Range  Up to 200 MPa (30k psi), depending on configuration
Operating Medium  All 6531 and 6532 E-DWT Kits are shipped dry, standard preparation. Can be filled with di-ethyl-hexyl sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol and distilled water or mineral oil.
Reservoir Capacity  300 cc (18 in3)
Variable Volume Displacement  3 cc (0.18 in3), 200 MPa (30,000 psi) maximum
Filling and Priming Pump Displacement  3.7 cc (0.23 in3)
TEST Pressure Connection  DH500 female, 200 MPa (30k psi) maximum working pressure. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. Adapter maximum working pressure is 140 MPa (20k psi). Note: DH500 is a gland and collar type fitting for 6 mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc.
Pressure Limits
Maximum Working Pressure  Range of RPM4-E-DWT monitor’s Hi Q-RPT
Maximum Priming Pump Pressure  700 kPa (100 psi)
Maximum Working Pressure  with Lo Q-RPT selected: Range of RPM4-E-DWT monitor’s Lo Q-RPT
Communication Ports  RS-232 (COM1, COM2)
Pressure Measurement 
Warm Up Time  15 minute temperature stabilization recommended from cold power up
Normal Operating Temperature Range  10 °C to 40 °C (50 °F to 104 °F)
Resolution  Default: 0.01 % of active range
User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger
Precision1
200 MPa (30,000 psi) ranges:  ± 0.018 % of reading or 0.0036 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.018 % of reading or 0.0018 % of Q-RPT span, whichever is greater
Predicted Stability 2
One year ± 0.0075 % of reading
Two years ± 0.015 % of reading
Measurement Uncertainty 3
One year
200 MPa (30,000 psi) ranges:  ± 0.02 % of reading or 0.004 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.02 % of reading or 0.002 % of Q-RPT span, whichever is greater
Two years
200 MPa (30,000 psi) ranges:  ± 0.025 % of reading or 0.005 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.025 % of reading or 0.0025 % of Q-RPT span, whichever is greater
Notes 1. Combined linearity, hysteresis, and repeatability. Precision does not include stability or calibration reference uncertainty.
2. Predicted Q-RPT measurement stability limit (k=2) assuming regular use of AutoZero function and short term stability between rezeroing.
3. Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted stability with rezeroing, temperature effect from 10 ºC to 40 ºC and calibration uncertainty (assumes calibration reference uncertainty of ±0.005 % of reading, k=2), combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 6531-XXX Electronic Hydraulic Deadweight Tester
Your Rating
Additional Information
SKU Fluke 6531-XXX
Manufacturer Part Code 4183614

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry