All Fluke Calibration Products

Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump

SKU
Fluke P3011-XXX-P
Rating:
0%
(0)
Reward Points
:
13000
£13,000.80 £10,834.00
Made to Order Free UK Delivery*
Advice & Support
Price Match Request
Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

The Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump is available in four models with varying vacuum ranges, please see the table below for further details.

Product Code Product Name  Vacuum Range
P3011-KPA-P Fluke P3011-KPA-P Vacuum Deadweight Tester (-100 kPA) With Pump 3 to 100 kPa
P3011-MBAR-P Fluke P3011-MBAR-P Vacuum Deadweight Tester (-1000 mbar) With Pump 30 to 1,000 mbar
P3011-INHG-P Fluke P3011-INHG-P Vacuum Deadweight Tester (-30 inHg) With Pump 1 to 30 inHg
P3011-MMHG-P Fluke P3011-MMHG-P Vacuum Deadweight Tester (-760 mmHg) With Pump 30 to 760 mmHg

This instrument can be used to test and calibrate pressure sensing modules designed to measure pressures below atmospheric pressure. It can be used to measure transducers, transmitters, gauges and pressure switches.

Unlike its sister product, the Fluke P3011-XXX Vacuum Deadweight Tester – Without Pump, this model includes an integrated hand-pump which can generate a vacuum to 90%. In addition to this, like its sister product, the Fluke P3011-XXX-P Vacuum Deadweight Tester can be used with an external vacuum pump in order to create a vacuum. The inclusion of a high-quality needle allows the user to make fine adjustments to the vacuum, ensuring that he/she is able to take accurate readings.

The Fluke P3011-XXX-P Vacuum Deadweight Tester has an accuracy of ±0.015% of the reading. This accuracy may be improved by calibrating the instrument with respect to the user’s local gravity. Unless specified, the Fluke P3011-XXX-P Vacuum Deadweight Tester will be calibrated to Standard Gravity (980.665 cm/s²). For further information, please contact our sales team before purchase.

As standard, the Fluke P3011-XXX-P Vacuum Deadweight Tester is supplied with an ISO 17025 accredited calibration certificate. It also features a cylinder and piston that have been constructed in accordance with the highest standards and therefore have certified accuracies traceable to international standard laboratories, such as the National Institute of Standards and Technology (NIST). They have been designed to improve stability and durability whilst lowering distortion and thermal coefficients, thereby helping to maintain the accuracy of this tester.

In addition to the above calibration certificate, the Fluke P3011-XXX-P Vacuum Deadweight Tester is supplied with spare seals, 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters as well as M20 and M14 metric adapters. Any vacuum weight masses supplied with this instrument are constructed from stainless steel and are marked with the serial number of the instrument and the nominal vacuum value. These weight masses can be stored in a robust case with a self-locking mechanism ensuring that they can be transported safely and securely between worksites. The Fluke P3011-XXX-P Vacuum Deadweight Tester itself is supplied with a detachable lid which also adds to its ease of transportation.

Adding to the practicality of this instrument is its physical design. The Fluke P3011-XXX-P Vacuum Deadweight Tester features a test station design with a mounted spirit level and adjustable feet which ensure that it can be easily set-up and used in a variety of environments. Furthermore, the addition of O-rings removes the need for PTFE tape or wrenches when connecting adapters and/or instruments.

The Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump is an easy-to-use, practical, adaptable instrument optimised for accurately calibrating pressure modules with ranges below atmospheric pressure.

Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump Key Features

  • Available in four models with varying pressure ranges
  • Test and calibrate pressure measuring instruments with ranges below atmospheric pressure
  • Can measure transmitters, transducers, gauges and pressure switches
  • Integrated hand-pump can generate a vacuum to 90%
  • May also be used with an external vacuum pump to generate a vacuum
  • An external vacuum pump can be attached to the tester’s /NPT port
  • High-quality needle allows the user to make fine adjustments to the vacuum
  • Accuracy: ±0.015% of the reading
  • Calibrated to Standard Gravity (980.665 cm/s²)
  • Option to calibrate the tester in accordance with the local gravity
  • Supplied with an ISO 17025 accredited calibration certificate
  • Cylinder and piston constructed in accordance with the highest standards
  • The piston includes a flotation indicator
  • Piston and cylinder have certified accuracies traceable to international standard laboratories, such as NIST
  • Cylinder and piston have been designed to lower distortion and temperature coefficients and improve stability and durability
  • Spare seals
  • 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters
  • M20 and M14 metric adapters
  • Stainless steel vacuum weight masses are marked with the instrument’s serial number and the nominal vacuum value
  • Weight masses can be stored in a robust case with a self-locking mechanism for safe and easy transportation
  • Tester is supplied with a detachable lid for easy transportation
  • Test station design
  • Mounted spirit level
  • Adjustable feet
  • Addition of O-rings removes the need for PFTE tape or wrenches when connecting adapters or instruments
  • Easy-to-use, practical, adaptable instrument

What’s Included?

  • Your Choice of Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump
  • Weight Masses
  • Removable Lid
  • 1/8, 1/4, 3/8, 1/2, NPT and BSP Adapters
  • M20 and M14 Adapters
  • ISO 17025 Accredited Calibration Certificate
  • Spare Seals

Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump Technical Specifications

Accuracy 
Accuracy ±0.015% of reading (±0.008% optional)

*Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.

Mass and PCU Materials of Construction 
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminium
Weight density 2.7 g/cm³
Piston Material Ceramic
Cylinder Material Martensitic steel
Coefficient of Expansion 11 ppm/°C
General 
Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 24 lbs
Instrument size 17.5 W x 12 D x 8.5 H
Mass set weight (typical) 65 lbs
Minimum Standard weight Increments 0.2 inHg (10 mbar)
Built-in Vacuum Hand Pump To 90% vacuum
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke P3011-XXX-P Vacuum Deadweight Tester – With Pump
Your Rating
Additional Information
SKU Fluke P3011-XXX-P
Manufacturer Part Code 4184251

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry