The Fluke P3013-XXX-P Gas Deadweight Tester – With Pump is designed to calibrate pressure sensing instruments. It is suitable for calibrating transducers, transmitters, gauges or pressure switches. This instrument is available in three models which vary with regards to their measurement ranges and units.  For further information, please see the table below.

Product Code Product Name  Pressure Range
P3013-KPA-P Fluke P3013-KPA-P Gas Deadweight Tester 200 kPa with Pump 3 to 200kPa
P3013-MBAR-P Fluke P3013-MBAR-P Gas Deadweight Tester 2000 mbar with Pump 30 to 2000 mbar
P3013-INH2O-P Fluke P3013-INH2O-P Gas Deadweight Tester 800 inH2O with Pump 12 to 800 inH2O

In order to generate pressure, the user can either attach an external gas source to the tester via the /NPT female external supply port or may use the integrated hand pump to create up to 300 psi (20 bar) of pneumatic pressure. The high-quality needle allows the user to make fine adjustments to the pressures generated using this instrument.

The creation of pressure causes the piston and assembly to rise. The user is able to balance this force by adding accurately calibrated weight masses on to the piston. The final pressure is then determined by adding together the nominal pressure values marked on each of the weight masses. For further information regarding this method, please see the video below.

Measuring Pressure with a Deadweight Tester

As indicated above any weight masses supplied with this tester are inscribed with the nominal pressure value relative to the high- or low-pressure piston. They are also marked with the instrument’s serial number and are constructed from series 3 non-magnetic austenitic stainless steel. These weight masses are stored in a rugged weight box with a secure locking mechanism, ensuring that they can be easily and securely transported.

Adding to this product’s ease of transportation is the inclusion of a detachable lid. Further to this, the Fluke P3013-XXX-P Gas Deadweight Tester is supplied with spare seals; 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters and M20 and M14 metric adapters. These adapters, combined with the deadweight calibrator’s test station design with O-rings, removes the need for PTFE tape and/or wrenches when attaching additional modules. In addition to this, the inclusion of a mounted spirit level and adjustable feet ensure that this instrument can be set up and used accurately in a variety of environments.

Moreover, the Fluke P3013-XXX-P Gas Deadweight Tester is supplied with an ISO 17025 accredited calibration certificate. Unless specified, the tester is calibrated to standard gravity (980.665 cm/s²); however, this instrument may also be calibrated to the user’s local gravity.

As standard this instrument has an accuracy of 0.015% of the reading; this can be improved to 0.008%. Adding to its accuracy is the construction of the piston/cylinder assembly which has been manufactured to the highest standards and as such has certified accuracies traceable to international standard laboratories, such as NIST (National Institute of Standards and Technology). Additionally, the piston/cylinder assembly has been constructed in order to provide stability and durability, as well as lower distortion and thermal coefficients.

This combination of features ensures that the Fluke P3013-XXX-P Gas Deadweight Tester – with Pump can be used to simply and accurately calibrate a number of pressure sensing modules.

Fluke P3013-XXX-P Gas Deadweight Tester – With Pump Key Features

  • Optimised for calibrating pressure sensing instruments
  • Ideal for checking transducers, transmitters, gauges and pressure switches
  • Available in three models with various pressure ranges and measurement units
  • Generate pressure using an external gas source
  • An external gas source can be attached via the /NPT female external supply port
  • Use the hand pump to create pressure up to 300 psi (20 bar)
  • High-quality needle facilitates fine pressure adjustments
  • Pressure causes the piston and cylinder assembly to rise
  • The upward force is balanced by the weight masses
  • Final pressure is determined by adding the pressure values on each weight mass
  • Weight masses are inscribed with the instrument’s serial number and the nominal pressure value relative to the high- or low-pressure piston
  • Weight masses are constructed from series 3 non-magnetic austenitic stainless steel
  • Weight masses are stored in a rugged weight box with a secure locking mechanism
  • The tester includes a detachable lid
  • Supplied with spare seals
  • Supplied with 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters and M20 and M14 metric adapters
  • Test station design with O-rings removes the need for PTFE tape and/or wrenches
  • Mounted spirit level
  • Adjustable feet
  • Supplied with ISO 17025 accredited calibration certificate
  • Calibrated to standard gravity (980.665 cm/s²)
  • Can be calibrated to local gravity
  • Standard accuracy: 0.015% of reading
  • Accuracy can be improved to 0.008%
  • Piston/cylinder assembly has been manufactured to the highest standards
  • Piston/cylinder has certified accuracies traceable to international standard laboratories (NIST)
  • Piston/cylinder is optimised for stability and durability
  • Piston/cylinder is designed to lower distortion and thermal coefficients
  • The piston includes a floatation indicator

What’s Included?

  • Your choice of Fluke P3013-XXX-P Gas Deadweight Tester – With Pump
  • Weight Masses
  • Removable Lid
  • ISO 17025 Accredited Calibration Certificate
  • Spare Seals
  • 1/8, 1/4, 3/8, 1/2 NPT and BSP Adapters
  • M20 and M14 Metric Adapters

Fluke P3013-XXX-P Gas Deadweight Tester – With Pump Technical Specifications

Accuracy 
Accuracy ±0.015% of reading (±0.008% optional)

*Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.

Mass and PCU Materials of Construction 
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminium
Weight density 2.7 g/cm³
Piston Material Ceramic
Cylinder Material Martensitic steel
Coefficient of Expansion 11 ppm/°C
General 
Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 24 lbs
Instrument size 17.5 W x 12 D x 8.5 H
Mass set weight (typical) 65 lbs
Minimum Standard weight Increments 2 inH2O, (10 mbar)
Built-in Pressure Hand Pump Max pressure 300 psi (20 bar)