All GE Druck Products

GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages

SKU
DPI620SPC-XBARG
Rating:
0%
(0)
As low as £9,185.40 £7,654.50
Free UK Delivery* Delivery Options

UK - Zone 1 Orders

England, Wales & most of Scotland.

Free 3-5 Working Day1
Orders Over £99 & Selected Items

Economy 2-3 Working Day1
From £1.95

Tracked 2-3 Working Day
£4.95

Express Next Working Day
£7.95

Priority Next Working Day
£14.95 (Pre-Noon)
£19.95 (Pre-10:30am)

Saturday & Sunday
£14.95 (Pre-Noon)

UK - Zone 2 Orders

Highlands, Islands & Northern Ireland.

Free 3-5 Working Day1
Selected Items (Calculated at Checkout)

Economy 2-3 Working Day2
From £1.95

Tracked 2-3 Working Day
£9.95

International Orders

Delivery is calculated at checkout.


Note: Next day delivery is not guaranteed for orders placed after 3:00pm. Prices Ex VAT.

1, 2 See delivery page for more details.

Price Match Guarantee & Advice

The GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages are suitable for use in hazardous areas and can be used to calibrate, test and set up a majority of process instruments such as transmitters, transducers, gauges/ indictors, switches, proximity detectors, counters, RTDs, thermocouples and valve positioners.

The GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages provide a complete calibration solution and are able to measure and generate pressure simultaneously, as well as, measure, source and simulate electrical parameters, frequency and temperature. These kits include the following GE Druck instruments:

  • GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator
  • GE Druck PM620-IS Intrinsically Safe Pressure Module (range dependent on package; 2, 7 or 20 bar versions available)
  • GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station with G1/8 Female and 1/8 NPT Adaptors (vacuum to 20 bar/ 300psi/ 2MPa)
  • Pressure Relief Valve (protects the pressure module from overpressure)
  • 4Sight2 Standard Calibration Software

For a complete list of all the products included in the GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages, please see the ‘What’s Included?’ section. For further information regarding the products listed above, please see the following descriptions.

GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator Description

To ensure the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator is suitable for use in Zone 1 and Zone 2 classified hazardous areas, it has been ATEX and IECEx approved. It has also been ETL approved for use in class 1, zone 1 hazardous locations.

The GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator can test, calibrate and set up a majority of process instruments and as such will provide simultaneous sourcing and measurement of electricity, frequency, temperature and pressure. It will source and measure the aforementioned parameters to the highest accuracy and is able to generate pneumatic pressures between 95% vacuum and 20 bar (300 psi/ 2 MPa) when used with the included GE Druck PVI621-IS Intrinsically Safe Pneumatic Pressure Generating Station.

In addition to simulating device inputs and measuring outputs simultaneously, the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator can calculate errors between inputs and outputs. It is also capable of logging the data for up to six channels simultaneously and will document ‘As Found’ and ‘As Left’ results. Moreover, this multifunctional calibrator can perform calibration procedures automatically.

Furthermore, to improve the ease and efficiency of testing, the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator includes a user-interface dashboard for launching setup, calibration and test applications, as well as a TASK menu which facilitates touch configuration. The user is able to perform touch configuration and selection for common tasks and devices such as pressure and temperature transmitters, transducers, switches and valve positioners. Additionally, frequently used and/or user-configured test procedures can be saved to FAVOURITES, again improving the simplicity and speed of testing and/or calibration procedures.

Moreover, the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator’s touchscreen interface with support for gestures and swipes allows for a flatter menu structure and thereby improves the ease and efficiency of use.

As the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator is compatible with a range of intrinsically safe GE Druck Pressure Modules, the user is able to expand its pressure range as necessary, allowing him/her to tailor the instrument to the application. Moreover, compatibility with the included 4Sight2 Standard Calibration Software expands the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator’s documenting, testing and administrative capabilities, transforming it into a complete calibration solution.

The GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator has the capacity to store all the procedures and results for a plant/ site in a complete database. Its ability to support a Windows desktop (please call for further details) allows the user to view standard office documents such as images, text files, spreadsheets and presentations.

The GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator provides an adaptable, multifunctional and complete calibration solution for use in hazardous environments.

GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator Key Features

  • ATEX and IECEx approved for use in Zone 1 and Zone 2 classified hazardous areas
  • ETL approved for use in class 1, zone 1 hazardous locations
  • Test, calibrate and set up a majority of process instruments
  • Simultaneous sourcing and measurement of electricity, frequency, temperature and pressure to the highest accuracy
  • Use with the GE Druck PVI621-IS Intrinsically Safe Pneumatic Pressure Generating Station to generate pneumatic pressure between 95% vacuum and 20 bar (300 psi/ 2MPa)
  • Simulates device inputs and measures outputs simultaneously
  • Calculates errors between inputs and outputs
  • Capable of logging data for up to six channels simultaneously
  • Documents ‘As Found’ and ‘As Left’ results
  • Performs calibration procedures automatically
  • User-interface dashboard for launching setup, calibration and test applications
  • TASK menu facilitates touch configuration/ selection of common tasks and devices
  • Frequently used and/or user-configured test procedures can be saved to FAVOURITES
  • Touchscreen interface with support for gestures and swipes
  • Flatter menu structure
  • Pressure range can be expanded as necessary using GE Druck’s interchangeable pressure modules
  • Compatible with calibration software such as the included 4Sight2 Standard Calibration Software
  • Capacity to store all the procedures and results for a site/ plant in a complete database
  • Support for Windows desktop (please call for details) allows the user to view images, text files, spreadsheets and presentations
  • An adaptable, multifunctional and complete calibration solution for use in hazardous environments

GE Druck PM620-IS Intrinsically Safe Pressure Modules Description

*** Please note that, depending on your selection, the GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages are supplied with either a 2bar, 7bar or 20bar GE Druck PM620-IS Intrinsically Safe Pressure Module. ***

Used to expand the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator’s pressure range, the GE Druck PM620-IS Intrinsically Safe Pressure Modules are available in ranges spanning 25mbar to 1000bar bar (10 in H2O to 15,000 psi / 2.5 kPa to 100 MPa), please contact our sales team for further details.

Like the aforementioned GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator, the GE Druck PM620-IS Intrinsically Safe Pressure Modules are ATEX and IECEx approved for use in Zone 1 and Zone 2 classified hazardous areas. It is also ETL approved for Class 1, Zone 1 hazardous environments. There are safe area versions of these pressure modules available, please contact our sales team for further information.

The GE Druck PM620-IS Intrinsically Safe Pressure Modules are accurate to 0.005% FS. Their screw-fit design makes the required pressure and electrical connections without the use of tools, sealing tape, cables or plugs. As a result, the GE Druck PM620-IS Intrinsically Safe Pressure Modules can be used interchangeably. Moreover, the GE Druck PM620-IS Intrinsically Safe Pressure Modules’ digital characterisation means that they do not require calibration or set up when used with the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator.

These interchangeable, simple-to-use and precise GE Druck PM620-IS Intrinsically Safe Pressure Modules are ideal for expanding the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator’s pressure range. (ONLY one 2bar, 7bar or 20bar module is included in each GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Package.)

GE Druck PM620-IS Intrinsically Safe Pressure Modules Key Features

  • Each package is supplied with ONLY one 2bar, 7bar or 20bar pressure module
  • Expand the GE Druck DPI620S Intrinsically Safe Pressure Calibrator’s pressure range
  • Available in ranges spanning 2mbar to 1000bar (please call for details)
  • ATEX and IECEx approved for use in Zone 1 and Zone 2 classified hazardous areas
  • ETL approved for Class 1, Zone 1 hazardous environments
  • Safe area versions are available (please call for details)
  • Accuracy: 0.005% FS
  • Screw-fit design makes pressure and electrical connections
  • No need for tools, sealing tape, cables or plugs
  • Digital characterisation means the pressure modules can be used with the calibrator without calibration or set up
  • Interchangeable, simple-to-use and precise pressure modules

GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station Description

The GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station is an easier to use, more efficient alternative to traditional hand pumps. It can be used to generate pressures between 95% vacuum and 20bar (300psi/ 2MPa).

In addition to this, the GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station can be used on a workbench as a comparator

The GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station is compatible with GE Druck’s pressure calibrators and pressure modules. As a result, the GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station can be used as part of a uniquely-capable, rearrangeable, and self-contained pressure test system.

The GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station is an adaptable, easy-to-use and versatile standalone pressure generator.

GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station Key Features

  • An easier to use, more efficient alternative to traditional hand pumps
  • Generates pressure between 95% vacuum and 20bar (300psi/ 2MPa)
  • Can be used on a workbench as a comparator
  • Compatible with GE Druck’s pressure calibrators and pressure modules
  • Can be used as part of a uniquely capable, rearrangeable, and self-contained test system
  • An adaptable, easy-to-use and versatile standalone pressure generator

4Sight2 Standard Calibration Software Description

The 4Sight2 Standard Calibration Software can be accessed from anywhere with an internet connection. It can be used to improve the ease, efficiency and precision of gathering and organising data.

This multi-lingual software program (choose from English, Dutch, German, Italian, Portuguese or Spanish) can be scaled to suit the user’s workload. The 4Sight2 Standard Calibration Software is able to accommodate single-site or global multi-site operations.

The 4Sight2 Standard Calibration Software includes the following capabilities and functions:

  • Automated calibration procedures (using a pressure calibrator)
  • Calibrations can be scheduled to reduce/ prevent downtime
  • Calibration procedures and routines can be defined and controlled per plant and per location
  • Automated processes
  • Automated calibration certificate creation
  • Easy-to-access audit trail and asset history

The 4Sight2 Standard Calibration Software is a versatile, simple-to-use and efficient calibration management software. It works as part of a complete calibration solution when used with the GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator, GE Druck PM620-IS Intrinsically Safe Pressure Module and GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station.

What’s Included?

  • GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator
  • GE Druck PM620-IS Intrinsically Safe Pressure Module (range dependent on package; 2, 7 or 20 bar versions available)
  • GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station with G1/8 Female and 1/8 NPT Adaptors (vacuum to 20 bar/ 300psi/ 2MPa)
  • Pressure Relief Valve (protects the pressure module from overpressure)
  • 4Sight2 Standard Calibration Software
  • Rechargeable Lithium-ion Battery
  • Universal Mains Adaptor and Charger
  • Test Leads
  • Calibration Certificate
  • Quick Reference Guide
Part Code

GE Druck DPI620G-IS-L Intrinsically Safe Pressure Calibrator Technical Specifications 

Processor and
memory
800 MHz Processor
512 MB 800 MHz SDRAM
8 GB Internal flash memory
Display Size: 110 mm (4.3 in) diagonal; 480 x 800 pixels 
LCD: Colour display with touch-screen
Protected by 2 mm toughened glass, impact tested in accordance with BS EN 61010-1:2010 (0.5 kg object from 1 m)
File Viewers A Windows® desktop is available for managing files, running third party applications and viewing simple images, Word documents, Excel spreadsheets, PDF files and PowerPoint files
Languages English {Default}, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Dutch, Japanese
Operating temperature -10° to 50°C (14° to 122°F)
Storage temperature -20° to 70°C (-4° to 158°F)
Ingress Protection IP54
Humidity 0 to 90% RH Non condensing
Shock / Vibration BS EN 61010-1:2010; MIL-PRF-28800F for Class II equipment, 1 m Drop Tested
EMC Electromagnetic compatibility: BS EN 61326-1:2006
Electrical safety Electrical – BS EN 61010-1: 2010
Pressure safety Pressure Equipment Directive - Class: Sound Engineering Practice (SEP)
Approval CE Marked
  ATEX & IECEx Intrinsically Safe: Ex II 2G Ex ib IIC T4 Gb (-10°C ≤ Ta ≤ +50°C)
  ETL Intrinsically Safe (US and Canada): Class I, Zone 1, AEx/Ex ib IIC T4 Gb (-10°C ≤ Ta ≤ +50°C)
Size (L: W: H) 183 x 114 x 42 mm (7.2 x 4.5 x 1.7 in)
Weight 575 g (1.3 lb) – battery included
Power supply Lithium-ion battery (P/N IO620G-IS-BATTERY); Capacity: 4800 mAh. Nominal voltage: 3.75 V. Charge temperature:
0° to 40°C (32° to 104°F) Discharge temperature: -10° to 50°C (14° to 12°F). Charge/discharge cycles: > 500 > 70% capacity.
Safe area charging only using external charger P/N: IO620G-IS-CHARGER and universal mains adaptor P/N: IO620-PSU.
The battery is detached from the instrument using two thumb screws and mounted on the charger.
The battery can be taken into a Hazardous Area without being connected to an instrument and can be attached and detached
in the Hazardous Area. The battery has an LED indicator to show the charge state of the battery without having to turn the
instrument on or when it is not attached to an instrument
Duration Measure functions (CH1): ≈ 7 hours continuous. Dual Function, mA measure (CH2): ≈ 5 hours (Loop enabled at 12 mA)
Connectivity USB Type Mini B (client)

GE Druck PM620-IS Intrinsically Safe Pressure Modules Technical Specifications 

Maximum intermittent pressure 2 x FS
Maximum working pressure 110% FS
Sealing IP 65 (protected against dust and
jets of water)
Operating temperature -10°C to 50°C (14°F to 122°F)
Storage temperature -20°C to 70°C (-4°F to 158°F)
Humidity 0 to 90% RH non condensing
Shock and vibration BS EN 61010-1:2010; MIL-PRF-28800F for Class II equipment, 1 m Drop Tested
EMC BS EN 61326-1:2006
Electrical safety BS EN 61010-1:2010
Pressure safety Pressure equipment directive class
SEP
Approval CE marked
ATEX & IECEx Intrinsically Safe: Ex II 1G Ex ia IIC T4 Ga
(-10°C ≤ Ta ≤ +50°C)
ETL Intrinsically Safe (US and Canada): Class I, Zone 1,
AEx/Ex ia IIC T4 (-10°C ≤ Ta ≤ +50°C)
Size and weight L. 56 mm, Dia. 44 mm,
106 g maximum

GE Druck PV621-IS Intrinsically Safe Pneumatic Pressure Generating Station Technical Specifications 

Maximum pressure 20 bar (300 psi / 2 MPa) pneumatic
Pressure media Non-corrosive gases
Operating temperature -10°C to 40°C (14°F to 104°F)
Approval CE Marked
ATEX & IECEx Intrinsically Safe: II 2G Ex ii IIC T4 Gb (-10°C ≤ Ta ≤ +40°C)
ETL Intrinsically Safe (US and Canada): Class I, Zone 1, AEx/Ex ia IIC T4 (-10°C ≤ Ta ≤ +40°C)
Storage temperature -20°C to 70°C (-4°F to 158°F) (must be empty of
water)
Shock and vibration BS EN 61010-1:2010; MIL-PRF-28800F for Class II
equipment, 1 m drop tested
Pressure safety Pressure equipment directive class SEP
Size and weight 450 mm x 280 mm x 235 mm,
PV621G 2.65 kg

 

0 Reviews Overall Rating

Write a Review

Write Your Own Review
You're reviewing:GE Druck DPI620S PC Intrinsically Safe Pressure Calibrator Packages
Your Rating

Subscribe to our Newsletter

International Enquiry