This Martindale ET6000 Kit is a cost-effective testing solution for installation verification and everyday electrical fault-finding.
The Martindale ET6000 undertakes the required measurements to verify electrical installations in accordance with the latest 18th Edition Wiring Regulations. The ET6000 has reliable high-current and non-trip loop testing, high input protection, and a CAT IV safety rating. For further information, please visit our Martindale ET6000 Multifunction Tester page.
The EZ165 Advanced Socket Tester can identify up to 28 socket wiring fault conditions, measure mains voltage levels, and verify earth continuity by performing a non-trip earth loop test. Please visit our EZ165 listing.
Completing the kit is the Martindale FD500 Circuit Breaker and Fuse Finder, which simplifies the process of identifying the correct fuse or circuit breaker controlling a circuit. It enables clear tracing from socket to socket and back to the fuse board.
Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.
| Voltage | 0V - 500V |
|---|---|
| Frequency | 10Hz - 499Hz |
| Complies with | BS EN 61010-1 CAT III 600V CAT IV 300V BS EN 61557 BS 57671:2018 18th Edition BS EN 61326-1 |
| Dimensions | 250mm x 107mm x 135mm |
| Weight | 1.3kg approx. (excl. batteries) |
| Insulation Resistance | Nominal voltages: 50, 100, 250, 500 and 1,000V DC |
| Continuity Resistance | Low R (200mA) |
| RCD Testing | Nominal residual currents: 10mA / 30mA / 100mA / 300mA / 500mA RCD type: A, AC, G, S |
| Other Features | Systems: TN, TT Optional rechargeable batteries |
| Nominal Operating Voltage | 230V AC rms ± 10% |
|---|---|
| Operating Frequency | 50Hz |
| Power Consumption | <2.5W |
| Power | from the main socket under test |
| Non-trip Earth Loop Impedance Ranges | 0 - 1.7 - 5 - 10 - 100 - 200 - 500Ω |
| Earth Loop Threshold Accuracy | ± (10% + 0.3Ω) *Measurement accuracy can be affected by highly inductive or capacitive loads distributed on the supply (see section 3.3.6). |
| Voltage Low Indication | <195V ± 5% |
| Voltage High Indication | >270V ± 5% |
| Earth Neutral Voltage High Indication | >30V nominal |
| Open Earth Indication | >500Ω ± 10% |
| Dimensions | 65 x 80 x 59mm |
| Weight | approx. 93g |
| Environment | For indoor use only |
| Temperature (Operating & Storage) | -10°C to 40°C, at max.60% RH |
| Altitude | up to 2000m |
| Pollution Degree | 2 |
| Safety | Conforms to BS EN 61010-1, CAT II 300V Class II, double insulation |
| EMC | Conforms to BS EN 61326-1 |
| Transmitter | |
|---|---|
| Voltage Rating | 230V |
| Frequency Range | 30 - 70Hz |
| Switching Frequency | Approx. 5Hz |
| Transmission Pulse Width | Approx. 1.7μS |
| Transmission Pulse Amptitude | 20A max. |
| Temperature Range | -10°C to 40°C at max 60% RH |
| Dimensions | Approx: 65 x 65 x 46mm |
| Weight | 60g |
| Earth Leakage | Nil |
| Power Supply | From mains |
| Power Consumption | Approx. 1W |
| Overvoltage Category | Cat III/300V |
| Pollution Degree | 2 |
| Protection Class | IP20 |
| Transmitter | |
| Tracing Depth for Fuse Assignment | Approx. 0 - 10cm, depending on local conditions |
| Sensitivity Setting | via on/off potentiometer |
| Temperature Range | -10°C to 40°C at max 60% RH |
| Dimensions | 160 x 55 x 30mm |
| Weight | Approx. 135g (including battery) |
| Protection Class | IP20 |
| Power Supply | 9V battery, MN1604/PP3, IEC 6LA61 (alkaline only) |