This Martindale ET6500 Kit is a single, practical bundle, making it well-suited to proving dead and working safely on electrical circuits.
The ET6500 Advanced Multifunction Installation Tester performs all measurements required to verify electrical safety in line with the latest 18th Edition Wiring Regulations. The ET6500 is also EV-ready and is supplied with the Martindale TL326-EV adapter. For further information, please visit our Martindale ET6500 page.
The VT25PD-S voltage testing set includes the VT25 two-pole tester and the PD690SRD proving unit. This combination safely and accurately tests AC and DC voltages, completes continuity checks, and performs phase rotation.
The kit also includes the Martindale LOKKIT1 lock-off kit, with nine locking devices, and the Lock-Out, Tag-Out (LOTO)introductory online course for one user.
Automatically adds to your basket when the total exceeds £1000+ (ex VAT). Limited Stock. More details here.
| Voltage | 0V - 500V |
|---|---|
| Frequency | 10Hz - 499Hz |
| Complies with | BS EN 61010-1 CAT III 600V CAT IV 300V BS EN 61557 BS 57671:2018 18th Edition BS EN 61326-1 |
| Dimensions | 250mm x 107mm x 135mm |
| Weight | 1.3kg approx. (excl. batteries) |
| Insulation Resistance | Nominal Voltages: 50, 100, 250, 500 and 1,000V DC |
| Continuity Resistance | Low R (200mA) |
| RCD Testing | Nominal residual currents: 6mA / 10mA / 30mA / 100mA / 300mA / 500mA / 650mA / 1000mA RCD type: A, AC, B, B+, F, G, S |
| Earth Resistance | Re (3-wire and 4-wire) 1Ω / 9999Ω Ro (Specific earth resistance testing) |
| Other Features | Systems: TT, TN, IT, LV (2 x 55V) Rechargeable batteries included EV ready & memory export |
| Nominal Operating Voltage | 230V ~ / 400V 3~ |
|---|---|
| Operating Frequency | 50/60 Hz |
| Dimensions | approx. Plug 230 x 60 x 55mm |
| Weight | approx. 300g |
| Mains Socket and Lead Rating | max. 10 A |
| PP Simulation | Set up internally to 20 A |
| CP Simulation | States A, B, C |
| Error Simulation | CP error “E” |
| Test Connector Type | IEC 62196-2 Type 2 male |
| Location | Suitable for indoor and outdoor use in dry weather conditions only |
| Altitude | up to 2000m |
| Operating Temperature Range | 0°C to 40°C |
| Storage Temperature | -0°C to 50°C |
| Relative Humidity Range | 0 – 80%RH |
| Mains Supply Voltage Fluctuations | ±10% |
| Overvoltage Category | CAT II 300V |
| Pollution Degree: | 2 |
| Safety | Conforms to BS EN 61010-1, BS EN 61010-031 Class II, Reinforced insulation |
| Power | Internal batteries |
|---|---|
| Internal Batteries | 6 x 1.5V, AA alkaline batteries (IEC LR6, NEDA 15A) |
| Dimensions | 150 x 80 x 35mm |
| Weight Packed | 435g approx. (with batteries) |
| Includes | 6 x 1.5V AA alkaline batteries instructions |
| Location | Suitable for indoor use and outdoor use in dry weather conditions only |
| Operating Temperature | -10°C to 40°C at max. 70% R.H. |
| Altitude | up to 2000m |
| Voltage Detector | |
|---|---|
| Maximum Working Voltage | 690V DC & AC rms |
| Nominal Voltage Threshold Indications | 12, 24, 50, 120, 230, 690V AC/DC |
| Nominal Voltage Threshold Tolerance | Conforms to BS EN 61243-3:2014 |
| Internal Impedance at ELV a.c. | 260kΩ |
| Polarity Indication | from 12V DC/AC rms |
| Range Detection | Automatic |
| Response Time | <1s to 100% of each nominal voltage |
| Frequency Range | DC, 16 to 400Hz |
| Test Current (In) | <3.5mA |
| Duty Ratio | 30s ON (operated) / 240s OFF (recovery) |
| Overvoltage Protection | 690V DC or AC rms |
| Single Pole Phase Test | |
| Voltage Range | 100 to 690V AC rms |
| Frequency Range | 50 to 60Hz |
| Phase Rotation Test | |
| Voltage Range | 120 to 400V AC rms (phase to earth) |
| Frequency Range | 50 to 60Hz |
| Continuity | |
| Resistance Range | 0 to 500kΩ + 50% |
| Test Current | 3μA |
| Overvoltage Protection: | 690V DC or AC rms |
| Environmental | |
| Temperature (Operating) | -10°C to 55°C |
| Temperature (Storage) | -20°C to 70°C, Non condensing |
| Humidity (Operating & Storage) | ≤ 85% R.H |
| Altitude | up to 2000m |
| Pollution Degree | 2 |