All Metrel Products

Metrel MI3360 OmegaPAT XA PAT Testers – Choice of Model

SKU
Metrel-MI3360
Rating:
0%
(0)

Choose a Special Offer

  • PAT Accessory Bundle
    110V Adapter + Logbook + 1,000 Labels (500 Pass, 250 Cord & 250 Fail) (PATBUNDLE)
    FREE
    £113.97
    £136.76
  • PAT Handbook, Logbook, 500 Pass / 250 Fail Labels
    PAT Handbook + Logbook + 750 Labels (500 Pass & 250 Fail) (PATBUNDLE3)
    FREE
    £55.45
    £66.54
Price Match Guarantee & Advice
Free Accessory Bundle
6 Bundle Deals Available...

The Metrel MI3360 OmegaPAT XA PAT Testers are downloadable PAT Testers, available in three models: the Metrel MI3360 OmegaPAT XA PAT Tester - Standard,  the Metrel MI3360 OmegaPAT XA PAT Tester – 25A, and the Metrel MI3360F OmegaPAT XA PAT Tester - Flash Test.

For a quck introduction to the Metrel MI3360 OmegaPAT XA PAT Testers, please see the following video.

The aforementioned models differ in the following ways:

  • The Metrel MI3360 OmegaPAT XA PAT Tester - Standard can perform earth bond resistance/ continuity tests at ONLY 200mA
  • The Metrel MI3360 OmegaPAT XA PAT Tester – 25A is able to perform continuity/ earth bond resistance tests at 10A and 25A as well as 200mA
  • The Metrel MI3360F OmegaPAT XA PAT Tester Flash Test features all the same testing capabilities as the above MI3360-25A model and also includes flash tests at 1500V and 3000V

For further information regarding the testing capabilities of these three models, please see the following table. 

Test Metrel MI3360 OmegaPAT XA PAT Tester - Standard Metrel MI3360 OmegaPAT XA PAT Tester - 25A Metrel MI3360F OmegaPAT XA PAT Tester - Flash Test
Visual Inspections Yes Yes Yes
Fuse Test Yes Yes Yes
Continuity / Earth Bond Resistance 200mA Yes Yes Yes
Continuity / Earth Bond Resistance 10A & 25A No Yes Yes
Insulation Resistance (Riso, Riso-S) Yes Yes Yes
Substitute Leakage Current Yes Yes Yes
Differential Leakage Current Yes Yes Yes
PE Leakage Current Yes Yes Yes
Touch Leakage Current Yes Yes Yes
Polarity / Active Polarity Yes Yes Yes
Power (P, S, Q, PF, THDu, THDi, Cosø, I, U) Yes Yes Yes
P-RCD, (2 pole, 3 pole, K/ Di (varistor), S (3-pole)) Yes Yes Yes
PRCD PE probe test, open conductor test, PE conductor test Yes Yes Yes
RCD test, (type A, AC, B, B+, F) Yes Yes Yes
Flash test (1500V, 3000V) No No Yes
Insulation Resistance, IEC/EN 62353 No No No
Touch Leakage Current, IEC/EN 62353 No No No
Equipment Leakage (Direct, Differential, Alternative), IEC/EN 62353 No No No
Applied Part Leakage (Direct, Alternative), IEC/EN 62353 No No No
Insulation resistance, (optional A 1422) IEC/EN 60974-4 Yes Yes Yes
Welding circuit leakage, (optional A 1422) IEC/EN 60974-4 Yes Yes Yes
Primary leakage, (optional A 1422) IEC/EN 60974-4 Yes Yes Yes
No-load voltage, (optional A 1422) IEC/EN 60974-4 Yes Yes Yes
Clamp Current (with optional A1283) Yes Yes Yes

All of these testers can also be used with Metrel’s A1283 Current Clamp Adapter (NOT included) to measure leakage currents and may be used with Metrel’s A1422 Active 3-phase Adapter Plus to test welding equipment in accordance with IEC/EN 60974-4.

Each model also features an integrated testing module for checking fuses of all types. Further to this, all variations of Metrel’s MI3360 OmegaPAT XA PAT Tester include additional test terminals for checking hard-wired devices.

As a result of these instruments’ testing capabilities, the Metrel MI3360 OmegaPAT XA PAT Tester - Standard is ideal for testing portable appliances found in hotels, schools and other public institutions. These appliances tend to fall into class I, class II or class III and often do not require comprehensive testing of continuity. Conversely, the Metrel MI3360 OmegaPAT XA PAT Tester – 25A can be used to test the continuity of appliances more comprehensively. It is particularly well suited to testing appliances found on construction sites and in factories and electrical equipment rental services. Alternatively, the Metrel MI3360F OmegaPAT XA PAT Tester is of particular use to those checking higher voltage appliances and/or appliances that have been recently repaired or sent for maintenance.

Each of these instruments is able to perform pre-defined test sequences optimised for particular appliances via the AUTOSEQUENCE® function. Further to this, Metrel’s MI3360 OmegaPAT XA PAT Testers include built-in filters ensuring that each model has a simple choice of test sequences relevant to its area of application.

Test results can be saved to the Metrel MI3360 OmegaPAT XA PAT Testers’ extensive, 8GB, microSD memory cards. Test sequences for specific appliances can also be saved to the microSD cards; these testers' microSD card memories are structured in such a way as to make the recall and re-execution of periodic tests for saved devices quick and easy.

Adding to these instruments' simplicity-of-use are their advanced user-interfaces, which enable the operator to perform pre-defined tests via the AUTOSEQUENCES® function, as mentioned above; their high-resolution, touch-screen, 4.3-inch, TFT displays; and their keyboard. These features allow the user to navigate the interface and enter information via his/her preferred method. In addition to this, the Metrel MI3360 OmegaPAT XA PAT Testers all support multiple user accounts. This allows the testers to be used by multiple electricians whilst ensuring that each individual’s test setups are maintained and his/her recorded results are not compromised.

Also adding to the practicality and simplicity-of-use of these PAT testers are their Bluetooth capabilities which facilitate the testers’ compatibility with the aMESM Android SW App, as well as Metrel’s Bluetooth QR Scanners and Printers (NOT included). This app and Metrel’s Bluetooth QR Scanners can be used to read test information contained in QR codes. This information can be used to populate the Metrel MI3360 OmegaPAT XA PAT Testers’ set-ups. Once the necessary appliance checks are completed, updated test information can be saved in a QR format and may be printed on a label via Metrel’s Bluetooth QR Label Printers. As a result testing efficiency is improved.

Alternatively, the Metrel MI3360 OmegaPAT XA PAT Testers can be used with the included PC SW Metrel ES Manager BASIC Software to create and upload test structures and AUTOSEQUENCES® to the tester. This software can also be utilised to archive test data and write professional reports.

The Metrel MI3360 OmegaPAT XA PAT Testers – Choice of Model are comprehensive, easy-to-use, sophisticated downloadable PAT testers; they are capable of testing a variety of portable appliances.

Metrel MI3360 OmegaPAT XA PAT Testers – Choice of Model Key Features

  • Downloadable PAT testers available in three models: a standard version, a 25A version, and a flash test version
  • The Metrel MI3360 OmegaPAT XA PAT Tester – 25A can perform earth bond resistance/ continuity tests at 25A and 10A as well as the standard 200mA
  • The Metrel MI3360 OmegaPAT XA PAT Tester - Standard can perform earth bond resistance/ continuity tests at ONLY 200mA
  • The Metrel MI3360F OmegaPAT XA PAT Tester - Flash Test can perform the all the same tests as the 25A version and features additional flash tests at 1500V and 3000V
  • Visual inspections
  • Fuse tests
  • Insulation resistance (Riso, Riso-S)
  • Substitute leakage current
  • Differential leakage current
  • PE leakage current
  • Touch leakage current
  • Polarity/ Active Polarity
  • Power (P, S, Q, PF, THDu, THDi, CosØ, I, U)
  • P-RCD (2 pole, 3 pole, K/Di (varistor), s (3-pole))
  • PRCD PE probe test, open conductor test, PE conductor test
  • RCD test (type A, AC, B, B+, F)
  • Insulation resistance (optional A 1422) IEC/ EN 60974-4
  • Welding circuit leakage (optional A 1422) IEC/ EN 60974-4
  • Primary leakage (optional A 1422) IEC/ EN 60974-4
  • No-load voltage (optional A 1422) IEC/ EN 60974-4
  • Use with Metrel’s A1283 Current Clamp Adapter (NOT included) to measure leakage currents
  • Use with Metrel’s A1422 Active 3-phase Adapter Plus (NOT included) to test welding equipment in accordance with IEC/EN 60974-4
  • Integrated testing module for testing fuses of all types
  • Additional test terminals for checking hard-wired devices
  • The Standard model is ideal for testing appliances that do NOT require comprehensive continuity testing
  • The Standard model is suitable for testing class I, class II and class III appliances found in hotels, schools and other public institutions
  • 25A model is ideal for testing appliances that DO require comprehensive continuity testing
  • 25A model is suitable for testing appliances found on construction sites and in factories and electrical equipment rental services
  • The Flash Test model is ideal for comprehensive continuity testing and performing high-voltage flash tests
  • The Flash Test model is suitable for testing high-voltage portable appliances as well as appliances that have recently been repaired or sent for maintenance
  • Perform pre-defined test sequences using the AUTOSEQUENCE® function
  • Built-in filters optimised for each tester’s area of application, resulting in a simple choice of test sequences
  • 8GB, microSD card memory
  • Save results and test sequences
  • The memory is structured to make the recall and re-execution of periodic tests for saved devices quick and easy
  • Advanced user-interface
  • High-resolution, touch-screen, 4.3-inch, TFT display
  • Keyboard
  • Supports multiple user accounts
  • Bluetooth capabilities
  • Can be used with Metrel’s aMESM Android SW App (NOT included) to scan QR codes and upload pre-configured AUTOSEQUENCES® to the tester
  • Can be used with Metrel’s Bluetooth QR Scanners (NOT included) to read test information which can be used to populate the test setup
  • Can be used with Metrel’s Bluetooth QR Printers ( NOT included) to print labels with QR codes
  • Can be used with the included PC SW Metrel ES Manager Basic Software to create and upload test structures and AUTOSEQUENCES® to the tester
  • Can be used with the above software to archive data and create professional test reports
  • Comprehensive, easy-to-use, sophisticated downloadable PAT testers
  • Capable of testing a variety of appliances

What’s Included?

  • Your Choice of Metrel MI3360 OmegaPAT XA PAT Tester
  • Accessory Bag
  • Smartball Pen with Touchscreen Function
  • Black Crocodile Clip
  • Black Test Lead
  • Black Test Tip
  • 2m IEC Test Cable
  • Mains Cable
  • USB Cable
  • Calibration Certificate
  • Short Form Instruction Manual
  • CD with Instruction Manual (full version)
  • PC SW Metrel ES Manager BASIC Software
  • Flash Test Probe (MI3360F Only)
  • Red Crocodile Clip (MI3360F Only)
Part Code

Metrel MI3360 OmegaPAT XA PAT Testers – Choice of Model Technical Specifications 

Continuity / Protective Earth Resistance
Continuity
Ranges 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω 
Resolution 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω \
Accuracy ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative
Operating range (acc. to EN 61557-4) 0.08 Ω … 199.9 Ω
Test currents 0.2 A,10 A, 25 A
Current source (at nominal mains voltage, use of standard accessories)  > 0.2 A at R < 2 Ω
> 10 A at R < 0.1 Ω at 230 V
> 25 A into short circuit at 230 V
Open circuit voltage < 9 V a.c.
Test Terminals
Continuity
R (200 mA) P/S – PE, Socket PE; Socket PE – IEC PE
R (10 A, 25 A) P/S – Socket PE; Socket PE – IEC PE
Protective Earth Resistance
R (200 mA) P/AP – PE, Socket PE
R (10 A, 25 A) P/AP – Socket PE
Insulation Resistance (Riso, Riso-S)
Insulation resistance, Insulation resistance –S (250 V, 500 V)
Range 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ 
Resolution 0.01 MΩ / 0.1 MΩ / 0.1 MΩ 
Accuracy ±(3 % of reading + 2 D) / ± 5 % of reading /± 10 % of reading
Output voltage (Um)
Range 0 V … 600 V 
Resolution 1V 
Accuracy ±(3 % of reading + 2 D)
Operating range (acc. to EN 61557-2) 0.08 MΩ … 199.9 (999) MΩ
Nominal voltages Un 250 V, 500 V (- 0 %, + 10 %)
Short circuit current max. 2.0 mA
Test terminals Riso LN, Socket LN – PE, Socket PE, P/S
Riso-S LN, Socket LN – P/S
Sub-Leakage Current, Substitute Leakage Current - S (Isub, Isub-S)
Range 0.00 mA … 1.99 mA / 2.00 mA … 19.99 mA 
Resolution 0.01mA / 0.01mA 
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Operating range (acc. to EN 61557-16) 0.02 mA … 19.99 mA
Open circuit voltage 230 V a.c., 110 V a.c.
Current calculated to mains supply voltage (110 V or 230 V) is displayed.
Test Terminals Isub LN, Socket LN – PE, Socket PE, P/S
Isub-S LN, Socket LN – P/S
Differential leakage current (Idiff)
Differential leakage current
Range 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
Resolution 1 µA / 0.01 mA 
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Power (active) (P)
Range 0 W … 999 W / 1.00 kW … 3.70 kW 
Resolution 1W / 10W
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Operating range (acc. to EN 61557-16) 0.010 mA … 19.99 mA
Influence of load current < 0.02 mA/A
Test terminals Idiff Socket L,N – Socket PE, P/S
P Socket L – Socket N
PE leakage current (Ipe)
PE leakage current
Range 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
Resolution 1µA / 0.01mA 
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Power (active) (P)
Range 0 W … 999 W / 1.00 kW … 3.70 kW 
Resolution 1W / 10W 
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Operating range (acc. to EN 61557-16) 0.010 mA … 19.99 mA
Test terminals Ipe Socket L,N – Socket PE
P Socket L – Socket N
Touch leakage current (Ipe)
Touch leakage current
Range 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA
Resolution 1 µA / 0.01mA 
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Power (active) (P)
Range 0 W … 999 W / 1.00 kW … 3.70 kW 
Resolution 1W / 10W
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Operating range (acc. to EN 61557-16) 0.010 mA … 19.99 mA
Test terminals Itou: Socket L,N – P/S
P: Socket L – Socket N
Power
Power (active) (P)
Range 0 W … 999 W / 1.00 kW … 3.70 kW 
Resolution 1W / 10W 
Accuracy  ±(5 % of reading + 5 D) / ±5 % of reading
Power (apparent) (S)
Range 0 VA … 999 VA / 1.00 kVA … 3.70 kVA 
Resolution 1 VA / 10VA 
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Power (reactive) (Q)
Range ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr 
Resolution 1 VAr / 10 VAr
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Power factor (PF)
Range 0.00i … 1.00i / 0.00c … 1.00c 
Resolution 0.01
Accuracy ±(5 % of reading + 5 D)
Total Harmonic Distortion (voltage) (THDU)
Range 0.0 % … 99.9 % 
Resolution 0.1 %
Accuracy ±(5 % of reading + 5 D)
Total Harmonic Distortion (current) (THDI)
Range 0.00 A … 16.00 A 
Resolution  0.01 A 
Accuracy ±(3 % of reading + 5 D)
Cosinus Φ (Cos Φ)
Range 0.00i … 1.00i / 0.00c … 1.00c 
Resolution 0.01 
Accuracy ±(5 % of reading + 5 D)
Current (I)
Range 0.00 A … 16.00 A 
Resolution  0.01 A
Accuracy ±(3 % of reading + 5 D)
Voltage (U)
Range 0.0 V … 199.9 V / 200 V … 264 V 
Resolution 0.1V / 1V
Accuracy ±(3 % of reading + 10 D) / ±3 % of reading
Test terminals
P,S,Q,PF,THDU,THDI, Cos Φ, I, U Socket L – Socket N
Leaks & Power
Power (active) (P)
Range 0 W … 999 W / 1.00 kW … 3.70 kW 
Resolution 1W / 10W 
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Touch leakage current: (Itou)
Range 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA
Resolution 1 µA / 0.01 mA
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Operating range (acc. to EN 61557-16) 0.010 mA … 19.99 mA
Differential leakage current (Idiff)
Range 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA 
Resolution 1 µA / 0.01 mA 
Accuracy ±(3 % of reading + 3 D) / ±(5 % of reading)
Operating range (acc. to EN 61557-16) 0.010 mA … 19.99 mA
Influence of load current < 0.02 mA/A
Power (apparent) (S)
Range 0 VA … 999 VA / 1.00 kVA … 3.70 kVA 
Resolution 1 VA / 10VA 
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Power (reactive) (Q)
Range ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr 
Resolution 1 VAr / 10 VAr
Accuracy ±(5 % of reading + 5 D) / ±5 % of reading
Power factor (PF)
Range 0.00i … 1.00i / 0.00c … 1.00c 
Resolution 0.01 
Accuracy ±(5 % of reading + 5 D)
Total Harmonic Distortion (voltage) (THDU)
Range 0.0 % … 99.9 % 
Resolution 0.1 % 
Accuracy ±(5 % of reading + 5 D)
Total Harmonic Distortion (current) (THDI)
Range 0.00 A … 16.00 A 
Resolution 0.01 A 
Accuracy ±(3 % of reading + 5 D)
Cosinus Φ (Cos Φ)
Range 0.00i … 1.00i / 0.00c … 1.00c 
Resolution 0.01 
Accuracy ±(5 % of reading + 5 D)
Current (I)
Range 0.00 A … 16.00 A 
Resolution 0.01 A 
Accuracy ±(3 % of reading + 5 D)
Voltage (U)
Range 0.0 V … 199.9 V / 200 V … 264 V 
Resolution 0.1V / 1V 
Accuracy ±(3 % of reading + 10 D) / ±3 % of reading
Test terminals
P,S,Q,PF,THDU,THDI, Cos Φ, I, U Socket L – Socket N 
Idiff Socket L,N – Socket PE, P/S
Itou Socket L,N – P/S
PRCD test
Trip-out time (tΔN)
Range 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N)
Resolution 1ms / 1ms / 1ms 
Accuracy ±3ms / ±3ms / ±3ms
*According to standard AS/NZS 3017
Trip out-current (IΔ)
Range 0.2xI∆N … 2.2xI∆N 
Resolution  0.05xI∆N 
Accuracy ±0.1xI∆N
Test current type sine-wave (AC), pulsed (A,F), smooth DC (B,B+)
Test currents (IΔN) 10 mA, 15 mA, 30 mA;.................100 mA and 300 mA with A1322, A1422
Test current size (PRCD standard is AS/NZS 3017) ±5%
Test current size (general) -0/+10%
Test terminals tΔN, IΔ Socket – IEC
RCD Test
Trip-out time (tΔN)
Range 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N)
Resolution 1ms / 1ms / 1ms 
Accuracy ±3ms / ±3ms / ±3ms
*According to standard AS/NZS 3017
Trip out-current (IΔ)
Range 0.2xI∆N … 2.2xI∆N 
Resolution 0.05xI∆N 
Accuracy ±0.1xI∆N
Contact voltage (Uc)
Range 0.0 V … 19.9 V / 20.0 V … 99.9 V 
Resolution 0.1V / 0.1V 
Accuracy  (-0 % / +15 %) of reading ± 10 D / 0.1 V (-0 % / +15 %) of reading
Test current type sine-wave (AC), pulsed (A,F), smooth DC (B,B+)
Test currents (IΔN) 10 mA, 15 mA, 30 mA
Test current size (RCD standard is AS/NZS AS/NZS) 5%
Test current size (EN 61008/EN 61009) -0/+10%
Test terminals tΔN, IΔ Mains Socket
PE conductor (PRCD)
PE conductor (Type = 2 pole, 3 pole, S(3 pole)) (R)
Range 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω 
Resolution 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω 
Accuracy ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative
Operating range (acc. to EN 61557-4) 0.08 Ω … 199.9 Ω
Current source (at nominal mains voltage, use of standard accessories) > 0.2 A at R < 2 Ω
Open circuit voltage < 9 V a.c.
Test terminals R Socket PE – IEC PE
PE conductor (Type = K/ Di (varistor))
Test principle: A voltage is applied between PE connections of the PRCD-K. There is a ‘PASS’ if PRCD trips.
Open circuit voltage 24 V
Output resistance 220 Ω ± 10 % (IΔN = 30 mA), 620 Ω ± 10 % ((IΔN = 10 mA)
Test terminals Result: Socket – IEC
Open conductor (PRCD)
Test principle: Mains voltage is applied to the mains test socket. Disconnection of the L, N and PE connections is performed inside the instrument. There is a ‘PASS’ if the PRCD trips.
Test terminals L open, N open, PE open Socket – IEC
PRCD PE probe test
Test principle: Mains voltage is applied to the mains test socket. A safe voltage sufficiently high to activate the protection circuit in the PRCD is applied to the P/S terminal.
Test terminals Result (manual): Socket, P/S
Result (auto): Socket – IEC, P/S
Polarity
Test voltage (normal) < 50 V
Test voltage (active) mains voltage
Power consumption of tested device during the active test < 25 VA
Test terminals Result (normal, active) Socket – IEC
Clamp current (I, Idiff, Ipe)
True RMS current using 1000:1 current clamp
Range 0.10 mA … 9.99 mA / 10.0 mA … 99.9 mA / 100 mA … 999 mA / 1.00 A … 9.99 A / 10.0 A … 24.9 A 
Resolution 0.01 mA / 0.1 mA / 1 mA / 0.01 A / 0.1 A
Accuracy ±(5 % of reading + 10 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits)
Notes Accuracy of current transformer is not considered.
Frequency range of current clamp is not considered.
Test terminals I, Idiff, Ipe: CLAMPS terminals
Insulation resistance Riso (welding equipment)
Riso
Range 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ 
Resolution 0.01 MΩ / 0.1 MΩ / 0.1 MΩ
Accuracy ±(3 % of reading + 2 D) / ±5 % of reading / ±10 % of reading
Output voltage (Um)
Range 0 V … 600 V 
Resolution 1 V 
Accuracy ±(3 % of reading + 2 D)
Operating range (acc. to EN 61557-2) 0.08 MΩ … 199.9 (999) MΩ
Nominal voltages Un 500 V (- 0 %, + 10 %)
Short circuit current max. 2.0 mA
Test terminals
Riso LN-W: A 1422 Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – W1 W2
Riso W-PE A 1422: Socket PE (16A-5p, 32A-5p or 16A-3p) – W1 W2
Riso LN-PE A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – Socket PE (16A-5p, 32A-5p or 16A-3p)
Riso LN (Class II) - P A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – MI 3360: P/S
General Specifications
Mains supply
Supply voltage, frequency 110 V / 230 V AC, 50 Hz / 60 Hz
Supply voltage tolerance 10 %
Max. power consumption 300 VA (without load on test socket)
Max. load 10 A continuous, 16 A short duration, 1.5 kW motor
Mains supply overvoltage category CAT II / 300V
Altitude ≤ 2000 m
Measuring categories
Instrument Cat II / 300 V
Test socket Cat II / 300 V
Plug test cable Cat II / 300 V
Altitude ≤ 2000 m
Protection classifications
Power supply Class I, mains supply, Class II, only battery supply
Pollution degree 2
Degree of protection IP40
IP20 (mains test socket)
Case Shock proof plastic / portable
Display Colour TFT display, 4.3 inch, 480 x 272 pixels
Touch screen Capacitive
Communication
Memory depends on microSD card size
RS232 interfaces 2
USB 2.0 Standard USB Type B
Bluetooth Class 2
Dimensions (w×h×d) 31 cm × 13 cm × 25 cm
Weight 6.1 kg
Reference conditions
Reference temperature range 15 ˚C … 35 ˚C
Reference humidity range 35 % … 65 % RH
Operation Conditions 
Working temperature range 0 ˚C … +40 ˚C
Maximum relative humidity 85 % RH (0 ˚C … 40 ˚C), non-condensing
Storage Conditions
Temperature range -10 ˚C … +60 ˚C
Maximum relative humidity 90 % RH (-10 ˚C … +40 ˚C)
80 % RH (40 ˚C … 60 ˚C)
Notes Accuracies apply for 1 year in reference conditions. Temperature coefficient outside these limits is 0.2 % of measured value per ˚C plus 1 digit, otherwise noted.
Fuses 2 x T 16 A / 250 V, 32 mm  6.3 mm / 1500 A

OmegaPAT XA Comparison Chart

Measuring function MI 3360 MI 3360 25A MI 3360 M MI 3360 F
Visual inspections
Fuse test
Continuity // Protective earth resistance 200mA
Continuity // Protective earth resistance 10A, 25A
Insulation Resistance (Riso, Riso-S),
Substitute Leakage Current, Substitute Leakage Current - S
Differential Leakage current
PE leakage current
Touch leakage current
Polarity / Active polarity test
Power (P, S, Q, PF, THDu, THDi, CosØ, I, U)
P-RCD, (2 pole, 3 pole, K/ Di (varistor), S (3-pole))
PRCD PE probe test, open conductor test, PE conductor test
RCD test, (type A, AC, B, B+, F)
Flash test, (1500V, 3000V)
Insulation resistance, IEC/EN 62353
Touch leakage current, IEC/EN 62353
Equipment leakage (direct, differential, alternative) IEC/EN 62353
Applied part leakage (direct, alternative), IEC/EN 62353
Insulation resistance, (optional A 1422) IEC/EN 60974-4
Welding circuit leakage, (optional A 1422) IEC/EN 60974-4
Primary leakage, (optional A 1422) IEC/EN 60974-4
No-load voltage, (optional A 1422) IEC/EN 60974-4
Clamp current (with optional A 1283)
0 Reviews Overall Rating

Write a Review

Write Your Own Review
You're reviewing:Metrel MI3360 OmegaPAT XA PAT Testers – Choice of Model
Your Rating