Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter

SKU
XMT1000-XXX
Rating:
0%
(0)
Call For Pricing

We require additional information before you purchase this product

or Call 01642 931 329 to discuss product options

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter is a completely configurable unit, available as a one-, two- or three-channel version and with four configurable inputs/outputs for analogue and digital communication (please see the datasheet for further details). It is suitable for use in hazardous (classified) areas, such as petrochemical and chemical-processing environments.

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter utilises ultrasonic technology to measure the flow velocity and flow direction of liquids contained in pipes of various sizes and materials. It can be used to test:

  • Hydrocarbon liquids
  • Liquefied Natural Gas (LNG)
  • Crude oil
  • Lubricating oil
  • Diesel fuel oil
  • Solvents
  • Water and wastewater
  • Hot/chilled water
  • Chemicals (liquid)
  • Beverages

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter builds upon the success of its predecessor, the Druck XMT868i Liquid Flow Transmitter. Like its predecessor, the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter can be installed at the process measurement point and does not feature any moving parts, filters or strainers, removing the need for periodic maintenance and calibration. This design also reduces the possibility of drifting and pressure drops. Similarly, this model, like its predecessor, utilises a transit-time flow measurement technique to determine flow velocity and direction.

To perform these measurements, the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter is used with wetted transducers. These instruments are installed directly inside the pipe or flowcell meaning that they come into contact with the liquid-under-investigation and, therefore, are able to provide a measurement accuracy of 0.3% of the reading. Please note that the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter can also be used as part of a variety of wetted systems, such as the PanaFlow System.

The transit-time measurement technique functions by using both the wetted transducers as senders and receivers of ultrasonic pulses. Each transducer emits the same number of ultrasonic pulses; the time it takes for these pulses to go from one transducer to the other is measured in both directions. If the fluid is stagnant then the upstream transit time will match that of the downstream transit time; however, if the fluid is moving the upstream transit-time is greater than the downstream transit-time. The difference between these transit times is proportional to the velocity of the liquid and the sign of this value indicates the direction in which the liquid is moving.

Like its sister product, the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter also includes an ATW™ (Automatic Tracking Window) function designed to maintain the unit’s accuracy despite unknown or changing fluid properties. The ATW™ function alters the time between the transit-signal window and the receive-signal window (Seek mode) to determine a clear receive-signal; this function sweeps through various time intervals based upon information entered by the user which details the expected maximum and minimum sound speeds. When an optimal ultrasonic receive-signal is identified, the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter will lock onto this signal and will only return to Seek mode when a significant change in sound speed is detected.

The ATW™ function is particularly useful when measuring multiproduct pipes, or when testing fluids with unknown fluid properties/ sound speeds or fluids with properties/ speeds which are affected by changes in environmental conditions.

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter’s onboard digital signal processor (DSP) will automatically adjust the transmitter in accordance with changing fluid properties; it also provides proprietary digital signal coding and correlation detection routines, as well as a dynamically configured operating software optimised for simplifying the programming of the transmitter.

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter features a magnetic six-button keypad operating interface, allowing the user to safely program the unit and verify diagnostics in hazardous (classified) locations. The user needs only touch the glass with the magnetic wand to change the parameter settings, as such, he/she does not need to open the Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter's casing in order to connect a PC to configure the unit. Similarly, he/she does not require a handheld programmer to operate the unit, nor are hot work permits required. 

However, as this unit is equipped with a MODBUS RS485 interface, it can also be programmed using a PC. Via this interface and GE Druck’s Vitality™ software, the operator can access the unit’s diagnostics and programming. The Vitality™ Software also facilitates continuous logging of up to 10 000 measurement points with up to twenty-six parameters logged per point.  

The Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter is a configurable, cost-effective and complete ultrasonic flow metering system suitable for measuring the flow of liquids in a variety of pipe systems.

GE Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter Key Features

  • Completely configurable unit available as one-, two- and three-channel versions
  • A one-channel model is cost-effective
  • Two-channel and three-channel models improve measurement accuracy and repeatability and add redundancy
  • Four configurable inputs/outputs for analogue and digital communication
  • Suitable for use in hazardous (classified) areas, such as petrochemical and chemical-processing environments
  • Utilises ultrasonic technology to measure the direction and flow of liquids contained in pipes of various sizes and materials
  • Measure the flow of hydrocarbon liquids, LNG, crude oil, lubricating oil, diesel fuel oil, solvents, water and wastewater, hot/chilled water, liquid chemicals and beverages
  • Can be installed at the process measurement point
  • Does not feature any moving parts, filters and strainers
  • Does not require maintenance or periodic calibration
  • Eliminates the possibility of drifting and pressure drops
  • Utilises a transit-time flow measurement technique to determine flow velocity and direction
  • Use with wetted transducers
  • Wetted transducers are installed directly inside the pipe or flowcell
  • Wetted transducers make contact with the liquid-under-investigation
  • Wetted transducers provide an accuracy of 0.3% of the reading
  • Can be used as part of a variety of wetted systems such as a PanaFlow System
  • ATW™ function works to ensure the unit’s accuracy when fluid properties/ sound speed are unknown or changing
  • The ATW™ function is particularly useful when measuring the flow of multiproduct pipes
  • The onboard digital signal processor (DSP) automatically adjusts for changing fluid properties
  • DSP provides proprietary digital signal coding and correlation detection routines as well as a dynamically configured operating software
  • A magnetic six-button keypad operating interface
  • Safely program and verify diagnostics in hazardous (classified) locations
  • Touch the glass with the magnetic wand to alter parameters
  • No need to open the case in order to program the unit via a PC
  • Does not require hot work permits to operate
  • A handheld programmer is not required to operate the unit
  • Can be programmed using a PC
  • MODBUS RS485 connectivity
  • Access the unit’s diagnostics and programming via a PC using GE Druck’s Vitality™ Software (NOT included)
  • Vitality™ Software facilitates continuous logging of up to 10 000 measurement points with up to twenty-six parameters logged per point
  • A configurable, cost-effective and complete ultrasonic flow metering system
  • Suitable for measuring the flow of liquids in a variety of pipe systems located in hazardous (classified) locations

What’s Included?

  • GE Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter (Configured to Your Specification)
Part CodeXMT1000-XXX

GE Druck PanaFlow XMT1000 Ultrasonic Flow Transmitter Technical Specifications 

Operation and Performance 
Fluid Types  Acoustically conductive fluids, including most clean liquids, and many liquids with entrained solids or gas bubbles. Maximum void fraction depends on the transducer, interrogation carrier frequency, path length and pipe configuration.
Transducer Type All liquid wetted transducers
Pipe Sizes Standard: 1 in. to 76 in. (25mm to 1930mm) 
Optional: >76 in. (1930mm), consult factory
Data Logging Storage standard on meter, up to 10 000 flow data points with up to 26 parameters per data point 
Measurement Parameters Volumetric flow, mass flow, flow velocity and totalised flow
Flow Accuracy (Velocity) Up to ±0.3% of reading (achievable when supplied with a complete flowmeter system and process calibration). Accuracy depends on the pipe size, installation and number of measurement paths.
The accuracy statement assumes measurement of a single phase homogeneous liquid with a fully developed symmetrical flow profile passing through the meter. Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification.
Repeatability  ±0.1% to 0.3% of reading
Range (Bidirectional) -40 to +40 ft/s (-12.2 to 12.2 m/s)
Meter Turndown 400:1
Electronics 
Enclosure Epoxy-coated aluminum or stainless steel
Dimensions (Standard)  Weight: 10 lb (4.5kg)
Size (D x H x W): 8.4in x 6.42in x 5.87in (213.4mm x 163.1mm x 149.1mm)
Channels One, two or three-channel options 
Display 128 x 64 mono-colour LCD display, configurable for single or dual measurement parameters
Keypad Built-in magnetic, six-button, lockable keypad
Standard Inputs/ Outputs One 4 to 20mA isolated output, 600Ω maximum load
One additional output, may be configured as either a pulse or frequency output
Digital Interfaces Standard: RS485/ Modbus®
Optional: HART® 7.0 protocol, with 4 dynamic variables, includes one additional 4 to 20mA analogue output
Optional: Foundation Fieldbus® FISCO, LAS capable with 5 Ai blocks and a PID block
Power Supplies Universal 100-240 VAC 50/60 Hz ±10% or 12 to 28 VDC
Power Consumption  15W maximum, Typically <7W

Inrush Current: 25A maximum @ 100µs

                         15A maximum @ 1ms

Temperature Range Operating: -40ºF to 140ºF (-40ºC to +60ºC)
Storage: -67ºF to +167ºF (-55ºC to +75ºC)
Optional PC Software Vitality™ PC Software for added functionality 
Certifications 

US/CAN: Class 1, Division 1, Groups B, C, D;

               Class I, Zone 1, Ex d IIC T6

               Class I, Division 2, Groups A, B, C, D:

               Class I, Zone 2, Ex nA IIC

ATEX/IECEx: Ex d IIC T6 FISCO outputs (pending)

Ta = -40ºC to +60ºC, Type 4X