  1. Time Electronics Milliamp Transducerline Simulator Transim 0 02 Percent Accuracy 2 All Time Electronics Products
    Free Delivery  
    Time Electronics 1077 Milliamp Transducer Simulator
    Rating:
    0%
    (0)
    £1,230.00 £1,025.00
    • Easy operation and LCD screen for measurement referencing
    • Three modes to choose from
    • Comes with free rubber protective case for fieldwork and travelling 
    2,050 Reward Points
    Price Match Guarantee
    SKU: 1077
  2. 709 Precision HART Loop Calibrator All Fluke Products
    Only 1 in Stock
    Free Delivery  
    Fluke 709 Precision HART Loop Calibrator
    Rating:
    0%
    (0)
    £1,255.14 £1,045.95
    Was £1,292.00
    You Save £246.05
    • HART communication tool
    • Small, portable and rugged device
    • Versatile range of advanced features
    2,090 Reward Points
    Price Match Guarantee
    SKU: FLUKE709H
  3. GE Druck DPI 832 Electrical Loop Calibrator All GE Druck Products
    Free Delivery  
    GE Druck DPI 832 Electrical Loop Calibrator
    Rating:
    0%
    (0)
    £1,256.28 £1,046.90
    Was £1,102.00
    You Save £55.10
    • Measure and source mA, mV and V
    • Portable, handheld design for use in the field
    • Also can be used as a pressure calibrator when combined with optional IDOS sensors
    2,092 Reward Points
    Price Match Guarantee
    SKU: DPI832
  4. Time Electronics Dc Voltage Calibrator 0 02 Percent Accuracy 1 All Time Electronics Products
    Free Delivery  
    Time Electronics 1010 DC Voltage Calibrator
    Rating:
    0%
    (0)
    £1,392.00 £1,160.00
    • Accuracy of 0.02%
    • Fitted safety terminals
    • Choose battery or mains power supply
    2,320 Reward Points
    Price Match Guarantee
    SKU: 1010
  5. GE Druck DPI 842 Frequency/Loop Calibrator All GE Druck Products
    Free Delivery  
    GE Druck DPI 842 Frequency/Loop Calibrator
    Rating:
    0%
    (0)
    £1,482.00 £1,235.00
    Was £1,305.00
    You Save £70.00
    • Measure and source frequency in sine, triangular and square waveforms
    • Handheld, portable design for use wherever you need it
    • mA measurement mode
    2,470 Reward Points
    Price Match Guarantee
    SKU: DPI842
  6. Time Electronics Dc Current Calibrator With Null Measuring 0 02 Percent Accuracy All Time Electronics Products
    Free Delivery  
    Time Electronics DC Current Calibrator with Null Measuring
    Rating:
    0%
    (0)
    £1,584.00 £1,320.00
    • Can be used in numerous situations
    • Compatible with different types of plugs
    • Incredible accuracy of 0.02%
    2,640 Reward Points
    Price Match Guarantee
    SKU: 1024
  7. Time Electronics Dc Multifunction Vir Calibrator 0 005 Percent Accuracy All Time Electronics Products
    Free Delivery  
    Time Electronics DC Multifunction V/I/R Calibrator
    Rating:
    0%
    (0)
    £1,722.00 £1,435.00
    • Tilt stand can be adjusted to suit you
    • Powered by rechargeable battery or mains plug
    • Five ranges of DC voltage
    2,870 Reward Points
    Price Match Guarantee
    SKU: 1017
  8. Fluke 710 mA Loop Valve Tester with HART - Front All Fluke Products
    Free Delivery  
    Fluke 710 mA Loop Valve Tester with HART
    Rating:
    0%
    (0)
    £2,314.80 £1,929.00
    • Optimised for testing complex smart valves
    • Integrated signature, step, speed and bump testing procedures
    • Includes a HART modem for communicating HART commands
    3,858 Reward Points
    Price Match Guarantee
    SKU: 4991049
View List Grid

8 Products

Page 1 of 1
per page

About Voltage, Current & Loop Calibrators

Also known as current loops, 4-20mA sources are one of the most common methods used in the process industry for transmitting data between sensors and the applications that control and monitor them. The main advantage of a current loop is they can be combined with a huge variety of different sensors to measure temperature, pressure, liquid flow or light. This data is then compatible with a wide range of different management applications that interoperate with the data and react accordingly.

4-20mA current loops work by taking the results from the sensor and converting it to a proportional current. This means that a zero result causes a 4mA to be transmitted and a 20mA current is sent when the sensor is at full capacity. This information is then sent through copper cables to a receiver at the controller. The controller then decodes the sent signal into the format that is required by the process monitoring application.

The drawback with this method is that over long distances the signal can eventually erode as the voltage begins to wane. An engineer must also be careful when laying these cables to ensure that no electrically noisy systems are located close by, otherwise they can affect the signal. The main precaution that can be taken is to ensure the use of shielded cabling but this can become too expensive if used over long distances.

To ensure that a current loop is operating effectively engineers often use current calibrators to test the cables and ensure that there are no issues that need resolving no matter what their source.