Black Friday Deals
All T and R Products

T&R ART3V 3-Phase Voltage & Frequency Relay Test System

SKU
ART3V
Rating:
0%
(0)
Reward Points (?)

Logged in, worth £224.40, read more.

:
22440
£13,464.00 £11,220.00
Only 1 in Stock Free UK Delivery* Delivery Options

UK - Zone 1 Orders

England, Wales & most of Scotland.

Free 3-5 Working Day1
Orders Over £99 & Selected Items

Economy 2-3 Working Day1
From £1.95

Tracked 2-3 Working Day
£4.95

Express Next Working Day
£7.95

Priority Next Working Day
£14.95 (Pre-Noon)
£19.95 (Pre-10:30am)

Saturday & Sunday
£14.95 (Pre-Noon)

UK - Zone 2 Orders

Highlands, Islands & Northern Ireland.

Free 3-5 Working Day1
Selected Items (Calculated at Checkout)

Economy 2-3 Working Day2
From £1.95

Tracked 2-3 Working Day
£9.95

International Orders

Delivery is calculated at checkout.


Note: Next day delivery is not guaranteed for orders placed after 3:00pm. Prices Ex VAT.

1, 2 See delivery page for more details.

Advice & Support
Price Match Request

The T&R ART3V 3-Phase Voltage & Frequency Relay Test System is an accurate and adaptable voltage source for relay testing with a 3-f voltage output from a 1-f supply, 0-450V f-N voltage output, 20VA/phase maximum output, ±180.0° phase shift, and a variable frequency between 30 and 999.9Hz. It is ideal for testing G59 and G99 schemes including loss of mains protection. It can also be used for testing and timing protection that requires one to three voltages such as:

  • Under and over frequency relays
  • Under and over voltage relays
  • Synchronising relays
  • df/dt & ROCOF relays
  • Vector surge relays
  • Transducers

Furthermore, when used in conjunction with T&R’s ART3C or 200ADM-P Secondary Current Injection Test Set, the T&R ART3V 3-Phase Voltage & Frequency Relay Test System is able to test the following protection circuits:

  • Directional relays
  • Distance protection
  • Phase angle relays
  • Power relays
  • Power transducers

Simplicity and accuracy are the defining features of the T&R ART3V 3-Phase Voltage & Frequency Relay Test System. It includes a new user interface which enables simple testing of complex voltage and loss of mains protection systems, a new full-colour LCD display for providing greater and clearer test detail, and higher output voltages with more precise accuracy and control.

The T&R ART3V 3-Phase Voltage & Frequency Relay Test System is able to provide a highly stable and accurate voltage output with very low distortion. The T&R ART3V 3-Phase Voltage & Frequency Relay Test System features automatic mains voltage selection and individually adjustable voltage, frequency and phase angle for each of its phase outputs. Values may be entered and altered using the smooth rotary encoder or using the capacitive keypad.

As the T&R ART3V 3-Phase Voltage & Frequency Relay Test System features a simple user interface within defined menus and dedicated panel buttons for each of the menu options, selecting the required mode of operation is easy. The T&R ART3V 3-Phase Voltage & Frequency Relay Test System features four modes of operation.

Output Adjust Mode

This operational mode provides full control of frequency, voltage and phase.

Phase Lock Mode

An external reference such as a voltage, current or the mains supply to the T&R ART3V 3-Phase Voltage & Frequency Relay Test System can be used to control the frequency and phase of the output. When used in conjunction with an external current source, the Phase Lock mode enables testing of directional and distance protection.

Fault Config Mode

The Fault Config Mode provides flexibility when testing complex timed events or when several sets of values must be applied to a relay in a specified order. If required, this mode also allows the user to change frequency, phase and voltage simultaneously.

Using the Fault Config mode, three sets of values, the pre-fault, fault and post-fault, can be set in advance. The T&R ART3V 3-Phase Voltage & Frequency Relay Test System can also be programmed to switch from one state to the next after a specific time or when a change of contact is detected. Furthermore, the T&R ART3V 3-Phase Voltage & Frequency Relay Test System’s timer can be configured to start or stop when a specific contact change has occurred or when a specified state change has happened.

Test configurations programmed using this mode can be saved to a USB. Alternatively, complex test sequences such as those pertaining to complete G59/ G99 relay tests or relay stability tests can be uploaded from a USB.

df/dt and ROCOF (Rate of Change of Frequency) Mode

Loss of mains protection is often a df/dt relay that is sensitive to the rate of change of frequency over time. This mode is used to generate a swept frequency output with accurate rates of change of frequency between pre-set frequencies.

As mentioned above, it is possible to create bespoke test procedures for step changes of any output variable at set times or with automatic timing of the response of the relay under test. These can be saved to and/or uploaded from a USB. It is also possible to save tests to a USB with comments entered using a USB keyboard. Tests and comments are saved in a CSV file enabling them to be opened on all PCs using a range of spreadsheet software.

Furthermore, to enable customisable test procedures, the T&R ART3V 3-Phase Voltage & Frequency Relay Test System features a flexible and multi-functional timing system.

All data, including contact set status and the phasor diagram, is displayed on the T&R ART3V 3-Phase Voltage & Frequency Relay Test System’s large, 6.5”, backlit, colour display. This voltage source for relay testing also includes 4mm safety sockets for A, B, C, and neutral. Neutral connections can be linked using the provide accessory to create a star connection; alternatively, a delta connection can be achieved by omitting the neutral. Finally, the T&R ART3V 3-Phase Voltage & Frequency Relay Test System is supplied in a rugged case and weighs less than 9kg.

The T&R ART3V 3-Phase Voltage & Frequency Relay Test System is a reliable, versatile and accurate voltage source for relay testing.

T&R ART3V 3-Phase Voltage & Frequency Relay Test System Key Features

  • Accurate and adaptable voltage source for relay testing
  • 3-f voltage output from 1-f supply
  • 0-450V f-N output voltage
  • 20VA/ phase maximum output
  • Variable frequency: 30-999.9Hz
  • Phase shift: ±180.0°
  • Test G59 and G99 schemes including loss of mains protection
  • Test protection that requires one to three voltages: under and over frequency relays, under and over voltage relays, synchronising relays, df/dt & ROCOF relays, vector surge relays, and transducers
  • Use with a current source to test directional relays, distance protection, phase angle relays, power relays, and power transducers
  • A new user interface which enables simple testing of complex voltage and loss of mains protection systems
  • New full-colour LCD display for providing greater and clearer test detail
  • Higher output voltages with more precise accuracy and control
  • Provides a highly stable and accurate voltage output with very low distortion
  • Automatic mains voltage selection
  • Individually adjustable voltage, frequency and phase angle for each of the phase outputs
  • Enter and alter values using the smooth rotary encoder or the capacitive keypad
  • Simple user interface within defined menus
  • Dedicated panel buttons for each of the menu options
  • Four modes of operation: Output Adjust, Phase Lock, Fault Config, and df/dt and ROCOF
  • Create bespoke test procedures for step changes of any output variable at set times or with automatic timing of the response of the relay under test
  • Save tests to and/or uploaded tests from a USB
  • Save tests to a USB with comments entered using a USB keyboard
  • Tests and comments are saved in a CSV file
  • Flexible and multi-functional timing system
  • See all data including contact set status and the phasor diagram on the display
  • Large, 6.5”, backlit, colour display
  • 4mm safety sockets for A, B, C, and neutral
  • Neutral connections can be linked using the provide accessory to create a star connection
  • A delta connection can be achieved by omitting the neutral
  • Supplied in a rugged case
  • Weighs less than 9kg
  • A reliable, versatile and accurate voltage source for relay testing

What’s Included?

  • T&R ART3V 3-Phase Voltage & Frequency Relay Test System
  • Rugged Case
  • Output Lead Set
  • Lead Set Case
  • Mains Lead
  • Spare Fuse Set
  • Operating Manual
Part Code

T&R ART3V 3-Phase Voltage & Frequency Relay Test System Technical Specifications 

Weight 8.9 kg
Dimensions 419 × 325 × 195 mm

Files & Downloads: