Time Electronics 7050 Multifunction Process Calibrator

Time Electronics 7050 Multifunction Process Calibrator
sku: 7050
MPN: 7050

Free UK Delivery On Orders Over £40
  • Calibrate thermocouples, RTDs and more
  • Fully programmable ramp format
  • Built into its own rugged carrying case

£4,650.00 Incl. VAT £5,580.00
Members earn 9300 points

Do you have a question or found it cheaper? Contact us

Description

Time Electronics 7050 Multifunction Process Calibrator Details

Designed for use with process equipment and various types of thermocouple, this calibration unit allows users to measure, simulate and calibrate these devices accurately.

The 7050's internal mechanism is actually built directly into the carry case, making porting this unit around extremely easy thanks to the included handle. When used in testing this device can measure 3 ranges up to 40V, 400mA and 40kΩ. It can also output voltage to 10V with 1μV resolution, outputs current to 20mA with 1μA resolution and outputs resistance from 0 to 400Ω with 0.01Ω resolution.

Since this calibrator is also a thermocouple calibration device, it can be used in combination with type J, K, T, R, S, B, N and E thermocouples to carry out temperature measurement and simulation in either degrees Celsius or Fahrenheit. It can also be used to simulate and measure RTD as well and the readouts are displayed automatically on the built-in screen as both input and output functions.

The 7050 also includes five calibration points which can be accessed via a preset percentage selector. This allows all functions to be generated in a fully user programmable ramp format.

This calibration unit can also be used as a signal converter and any electronic input signal can be converted and be output as a proportional signal of 4-20mA, 0.5V or square root 4-20mA.

The 7050 is powered either by batteries or can be powered by the mains.

Time Electronics 7050 Multifunction Process Calibrator Key Features

  • Built into its own protective carrying case
  • Simulate and measure various types of thermocouple, RTDs and process equipment
  • Three measurement ranges: 40V, 400mA and 40kΩ
  • Output voltage of 10V with 1μV resolution
  • Output current of 20mA with 1μA resolution
  • Output resistance to 0 to 400Ω, 0.01Ω resolution
  • Measure and simulate type J, K, T, R, S, B, N and E thermocouples
  • RTD measure and simulate functions
  • Ramp function
  • Battery or mains operation
  • Signal generation
  • Programmable RTD and thermocouples
  • Preset calibration point selector
  • Easy input and output switching functions
  • Celsius and Fahrenheit units
Technical Specs

Part Code: 7050

Time Electronics 7050 Technical Specifications

INPUT

Voltage
Range Resolution Accuracy
40V 1mV 0.03%
4V 100μV 0.03%
400mV 10µV 0.03%
40mV 1µV 0.03%
Current
Range Resolution Accuracy
400mA 10μA 0.03%
40mA 1μA 0.03%
4-20mA/0-100% 0.01% 0.06%
Resistance
Range Resolution Accuracy
40000Ω 0.03%
4000Ω 0.1Ω 0.03%
400Ω 0.01Ω 0.06%

 

OUTPUT

Voltage
Range Resolution Accuracy
-2 to +10V 1mV 0.06%
-100mV to +400mV 10μV 0.03%
-10mV to +40mV 1µV 0.03%

Output Impedance: < 10Ω

Current
Range Resolution Accuracy
0 to 20mA 10μA 0.03%
4 to 20mA 1μA 0.03%
TX Sim (4 to 20mA) 0.01% 0.03%

Max Load Resistance: 900Ω at 20mA, Open circuit voltage 18- 27V 

Resistance
Range Resolution Accuracy
0 to 400Ω 0.01Ω ± 0.03%

Excitation Current 0.2 to 2mA 

Other Specifications: Loop drive supply: Nominal 24V, current limit set to 30mA


Process Signal and Temperature Measurement & Simulation

Temperature
Thermocouple Type Temp Range °C Accuracy °C

J

-210 to 0
0 to 710
710 to 1200

± 0.4 
± 0.2 
± 0.9

K

-270 to -240 
-240 to -180 
-180 to -50 
-50 to 960 
960 to 1370

± 3.0 
± 1.2 
± 0.5 
± 0.3 
± 1.7

T

-270 to -250 
-250 to -180 
-180 to -100 
-100 to 400

± 3.0 
± 1.0 
± 0.5 
± 0.2

R

-50 to 0 
0 to 70 
70 to 400 
400 to 1000 
1000 to 1760

± 3.0 
± 2.0 
± 1.5 
± 1.0 
± 0.8

S

-50 to 0 
0 to 100 
100 to 450 
450 to 1760

± 2.5 
± 1.8 
± 1.3 
± 0.9

B

200 to 400 
400 to 1000 
1000 to 1820

± 5.0 
± 2.0 
± 1.0

N

0 to 330 
330 to 1100 
1100 to 1300

± 0.4 
± 0.3 
± 1.5

E

-230 to 0 
0 to 540 
540 to 1000

± 0.5 
± 0.2 
± 1.5

RTD - PT100
Range °C Accuracy °C
-200 to 850 ± 0.3
Thermocouple Linearisation to BS 4937. ITS 90 or IPTS68 selectable.
Pt100 Linearisation to BS1904 (1984).DIN43760 (1980). Linearisation Acc: 0.1% of reading for Class A, 38.5Ω F.I
Excitation current 0.5mA (Input), 200μA to 2mA (Output).
CJC External (Pt100), Internal, Ice point. Accuracy +/-0.2°C at 23°C
Ramp Fully programmable continuous and stepped
Steps 5 Steps with fully adjustable zero
Transmitter Tx function 4-20mA
Signal Converter Any input to any output
Dual Readout Measure and source simultaneously displayed


General Specifications

Stability 100ppm per °C range 0 to 40°C
Displays LCD Dot Matrix, 1 line by 20 charx12mm, alphanumeric.

Dimensions / Weight

W270 x H175 x D250mm, weight 4.5kg

Optional Extras Calibration Certificates traceable to NPL and UKAS
Reviews

We'd really appreciate it if you'd review this product

Why not leave a review of this product? Reviews help us improve our service for customers looking for a product to make a decision.

No reviews have been found

Write Your Own Review

How do you rate this product? Required *

 
1
2
3
4
5
Value
Quality
Price