Free Tyre Inflator. Spend £500+ (ex VAT) View

Additel 685EX ATEX Digital Pressure Gauge with Optional Data Logging

Free Tyre Inflator (Spend £500+)
All Additel Products
  • Pressure ranges up to 60,000 psi (4,200 bar)
  • 0.02%, 0.05% FS or 0.1% RD Accuracy
  • Gauge, Compound, or Differential pressure
SKU
ADT685EX
MPN
ADT685EX

Read More

The Additel 685Ex Digital Pressure Gauge is an intrinsically safe, fully temperature-compensated digital pressure gauge for use in hazardous areas. It uses microprocessor control and silicon pressure sensors to deliver stable, repeatable measurements in field and process applications.

A 3.4-inch colour touchscreen with tempered glass provides menu-based setup and operation. The enclosure is IP67 rated for dust and water protection.

An internal barometric sensor (50 Pa accuracy) enables gauge, absolute, and atmospheric pressure measurement. Optional internal data logging stores over 10 million records, including date, time, pressure, and temperature.

ADT685 Digital Pressure Gauges
Additel 685 / 686 / 673 - Product Details & Differences
Additel Pressure Gauge Screen Durability Showcase

Key Features

  • Pressure ranges up to 60,000 psi (4,200 bar)
  • 0.02%, 0.05%FS or 0.1%RD accuracy
  • Fully temperature compensated accuracy
  • Every model measures Gauge or Absolute Pressure
  • Built-in Barometer
  • Touchscreen display
  • Intrinsically safe
  • Bluetooth and USB communications
  • Data logging (optional)
  • IP67 rated
  • Communicates with Additel's Link Mobile App
  • ISO 17025-accredited calibration w/data included

Ordering Information

The part number is broken down into codes so you can easliy customise your instrument.

Model Accuracy Pressure Range P/N Range Type Pressure Port Type Data Logging Comm Port (Optional)
Options
ADT685Ex 01 - 0.01% of full span
02 - 0.02% of full span
05 - 0.05% of full span
10 - 0.1% of full span
20 - 0.2% of full span
RD - 0.1% of reading
See pressure range table PSI-range by psi
BAR-range by bar
H2O-range by inH2O
N- 1/4NPT male
N2- 1/2NPT male
B-1/4BSP male
B2-1/2BSP male
M-M20 X 1.5 male
AF-Autoclave F-250-C female
AM-Autoclave M-250-C male
DL 232 = RS - 232
Example
ADT685Ex 02 GP300 PSI N DL 232

What's Included?

  • Pressure gauge
  • Rubber boot
  • Three AA alkaline batteries
  • USB cable (type-C)
  • Silicone tube - 1 meter each (2 pcs for DP models only)
  • ISO 17025 Accredited Calibration Certificate
Additel 685 Link Video
Introduction to Pressure Calibration - Additel Basics
Calibration Terminology - Additel Basics
Types of Pressure Measurement Devices - Additel Basics
Call for Pricing

We require additional information

Call 01642 931 329 or complete the form:

Offers

Free Tyre Inflator (Spend £500+)

Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.

Technical Information
Specification
Intrinsic Safety & European Compliance CE marked, CSA marked
ATEX certified intrinsically safe
II 1G EX ia IIC T4 Ga
Accuracy
(For detailed accuracy, please see the pressure range table)
685Ex-01: 0.01% of full span; 02: 0.02% of full span; 05: 0.05% of full span
685Ex-RD: 0% to 20% of range: 0.02% of full span
20% to 110% of range: 0.1% of reading
Built-in barometer: 55 Pa
Gauge Types Gauge pressure, compound pressure, absolute pressure, differential pressure and barometric pressure
Display Touch screen (3.4'' FSTN segment capacitive) - 5 1/2 full digits
Screen protector: tempered glass film (replaceable)
Display rate: 3 readings per second (default setting)
Adjustable from 10 readings per second to 1 reading every 20 seconds
Pressure Units[2] Pa, kPa, MPa, psi, bar, mbar, kgf/cm2, inH2O@4°C, mmH2O@4°C, inHg@4°C, mmHg@4°C and 3 customizable units
Environmental Compensated Temp.: 14°F to 122°F (-10°C to 50°C)
Operating Temp.: 14°F to 122°F (-10°C to 50°C)
Storage Temp.: -4°F to 158°F (-30°C to 70°C)
Humidity: 0 - 95%, Non-condensing
Pressure Port < 15,000 psi: 1/4NPT male, 1/2NPT male, 1/4BSP male, 1/2BSP male, M20 x 1.5 male
≥15,000 psi: 1/4HP female or 1/4HP male
*1/4HP female: Autoclave F-250-C, 9/16" - 18 UNF-2B
*1/4HP male: Autoclave M-250-C, 9/16" - 18 UNF-2A
Differential Pressure: barb fitting
Other connections available per request
Power Battery: three AA alkaline batteries (included)
Battery life: 1500 hours typical
Power auto-off: user selectable
External power: 110/220 V adapter (5 VDC) (optional, excl ADT685Ex)
Enclosure Case material: 304 SS
Wetted parts: 316 SS[1]
Size: 4.65" x 1.77" 7.01"(118 x 42 x 178 mm)
Weight: 1.50 (0.68 kg)
Compliance Protection Level: IP67
Vibration: 5 g (10-500 Hz)
Shock Resistance: 8 g/11 ms
Data Logging
(Available on data logging option ADT685-...-DL)
Data storage: 10,000,000 records
Rate: user-selectable from 0.1 to 9999.9 second intervals
Communication USB Type-C and Bluetooth included
RS-232
Additel Warranty 1 Year
[1] Wetted parts material types may vary by pressure range
[2] Available units are dependent on the overall pressure range
Document Downloads
Additel 685 Digital Pressure Gauge Datasheet Datasheet
Additel 685 Digital Pressure Gauge User Manual Manual/Guide
Additel 685 Digital Pressure Gauge Resolution Guide Manual/Guide
Additel 685 Digital Pressure Gauge Calibration Manual Manual/Guide
Additel 685 Digital Pressure Gauge Command Sets Manual/Guide
Additional Information
SKU
ADT685EX
Manufacturer Part Code
ADT685EX

Customer Reviews

 
Additel 685EX ATEX Digital Pressure Gauge with Optional Data Logging