The Fluke 7103 Micro Bath Temperature Calibrator – Choice of Range provides the user with the accuracy and stability of a liquid bath, contained within a unit the size of a dry well calibrator.

The Fluke 7103 Micro Bath Temperature Calibrator is available in two models with different temperature ranges; for further details, please see the table below.

Product Code Product Name  Temperature Range
7103-256 Fluke 7103-256 Micro Bath Temperature Calibrator 

–30 °C to 125 °C

(–22 °F to 257 °F) 

7103-TR-256 Fluke 7103-TR-256 Micro Bath Temperature Calibrator 

 -20°C to 150°C

(-4°F to 65°F)

Both of these models include an over-temperature cut-out, which works to protect the user’s safety and prevent damage to the unit.

The Fluke 7103 Micro Bath Temperature Calibrator can be used to calibrate temperature sensors of various shapes and sizes, as well as thermal switches. It is also particularly well suited to calibrating liquid-in-glass and bimetal thermometers. This versatility of application is made possible by the inclusion of a contact that is designed for the calibration of thermal switches, as well as an integrated tank with a depth of 140mm (5.5”) and diameter of 48mm (1.9”). The depth of this tank ensures that sensors of various descriptions can be easily immersed in the fluid.

Water, mineral oil and silicone oil can all be used to serve as bath fluid. Depending on the fluid used, the instrument has a stability of ±0.03°C or better. In addition to this, the Fluke 7103 Micro Bath Temperature Calibrator has a uniformity of ±0.02°C, ensuring that it provides the user with low uncertainties when it is used with a reference thermometer. Alternatively, the operator is able to use the Fluke 7103 Micro Bath Temperature Calibrator to perform quick calibrations without a reference thermometer as a result of its ±0.25°C accuracy. Please note that the values given for the stability, uniformity and accuracy of the Fluke 7103 Micro Bath Temperature Calibrator are true of the instrument’s entire temperature range.

Temperature readings can be saved to the Fluke 7103 Micro Bath Temperature Calibrator’s eight-point storage memory. Alternatively, the user is able to view these readings remotely on his/her PC due to the inclusion of an RS-232 port and Fluke’s Interface-It Software. This software also allows the user to operate the Fluke 7103 Micro Bath Temperature Calibrator via his/her computer as it provides access to instrument's features and functions, such as the ramp-rate,  which may be adjusted to suit the user’s needs.

Additionally, this instrument can be used with Fluke’s MET/ TEMP II Software (NOT included). Like the supplied Interface-It Software, this program can be used to view the Fluke 7103 Micro Bath Temperature Calibrator’s readings and adjust its settings. However; this software also allows the user to generate calibration constants and reference tables.

As well as its versatility, accuracy and software compatibility, the Fluke 7103 Micro Bath Temperature Calibrator has also been optimised for practicality and ease-of-use. To this end, it is supplied with a seal-proof lid which allows the user to transport the micro bath between and across worksites with the liquid already added to the tank. Moreover, as a result of its sophisticated design, the Fluke 7103 Micro Bath Temperature Calibrator is capable of CFC-free refrigeration, removing the need for a compressor to generate and maintain the required temperatures. This has resulted in the Fluke 7103 Micro Bath Temperature Calibrator's more compact, portable and lightweight design, again ensuring that it can be easily handled and transported.

Despite its compact, lightweight and portable design, the Fluke 7103 Micro Bath Temperature Calibrator does not compromise on its performance. It is ideal for those requiring a temperature calibrator with the stability and accuracy of a liquid bath but with the size and practicality of a dry well tester.

Fluke 7103 Micro Bath Temperature Calibrator – Choice of Range Key Features

  • Offers the stability and accuracy of a liquid bath contained within a unit the size of a dry well calibrator
  • Available in two models with different temperature ranges
  • Over-temperature safety cut-out
  • Calibrate temperature sensors of various designs and thermal switches
  • Particularly well suited to calibrating liquid-in-glass and bimetal thermometers
  • Includes a contact for thermal switch calibration
  • Integrated tank with a depth of 140mm (5.5”) and a diameter of 48mm (1.9”)
  • The design of the tank ensures that sensors of various shapes and sizes can be immersed
  • Water, mineral oil and silicone oil can be used as bath fluid
  • Stability of ±0.03°C or better (depending on the fluid used)
  • Uniformity of ±0.02°C provides the user with low uncertainties when it is used with a reference thermometer
  • Its accuracy of ±0.25°C allows the micro bath to perform quick calibrations without a reference thermometer
  • Specifications given for the micro bath’s stability, uniformity and accuracy are applicable to all the temperatures within the instrument’s range
  • Eight-point storage memory
  • RS-232 port facilitates a connection to the user’s PC
  • Supplied with Fluke’s Interface-It Software allowing the user to view temperatures remotely on his/her PC
  • Interface-It Software can also be used to operate the micro bath as it provides access to the instrument’s features and functions, such as the ramp-rate, which may be adjusted to suit his/her requirements
  • Can also be used with Fluke’s MET/ TEMP II Software (NOT included)
  • Seal-proof lid allows the calibrator to be transported with the fluid in the tank
  • CFC-free refrigeration removes the need for a compressor
  • Compact, portable, lightweight design
  • Easy to handle and transport
  • Ideal for those requiring a temperature calibrator with the stability and accuracy of a liquid bath but with the size and practicality of a dry well tester

What’s Included?

  • Your Choice of Fluke 7103 Micro Bath Temperature Calibrator
  • Transport Seal Lid
  • Spare 2082-P Test Lid
  • Fluke Interface-It Software
7103-256

Fluke 7103 Micro Bath Temperature Calibrator – Choice of Range Technical Specifications

Specifications 7103-256 7103-TR-256
Range 

–30 °C to 125 °C

(–22 °F to 257 °F) 

 -20°C to 150°C

(-4°F to 65°F)

Accuracy  ± 0.25 °C 
Stability ± 0.03 °C at –25 °C
(oil 5010)
± 0.05 °C at 125 °C
(oil 5010) 
Uniformity  ± 0.02 °C 
Resolution  0.01 °C/°F 
Operating Temperature  5 °C to 45 °C 
Heating Time  25 °C to 100 °C:
35 minutes 
N/A
Cooling Time  25 °C to –25 °C:
45 minutes 
N/A
Well Size  64 mm dia. x 140 mm deep (2.5 x 5.5 in) (working area is 48 mm [1.9 in] in diameter) 
Size (WxHxD) 23 x 34 x 26 cm
(9 x 13.2 x 10.5 in) 
Weight 9.8 kg (22 lb) with fluid
Volume  1.0 L (2.11 pints) 
Power  94–234 V ac (± 10 %), 50/60 Hz, 400 W 
Computer Interface RS-232 interface
NIST-Traceable Calibration  Data at –25 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 125 °C 
Commonly Used Fluids1  Water (distilled)
Mineral Oil
Silicone Oil
1 Refer to the Users Guide for information on selecting the right bath fluid for your application.
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 7103 Micro Bath Temperature Calibrator – Choice of Range
Your Rating
Additional Information
SKU Fluke 7103
Manufacturer Part Code 1657627

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry