Fluke 9173-X-R-256 Field Metrology Well w/ Reference Thermometry
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

The Fluke 9173-X-R-256 Field Metrology Well w/ Reference Thermometry can be used to calibrate temperature sensing instruments, such as thermometers, temperature probes and thermal switches. It has a temperature range of 50°C to 700°C and is available in six models with varying disc inserts. For further information, please see the table below.

Product Code  Product Name 9173 Disc Insert Name Disc Insert Part Number  Hole Types
9173-B-R-256 Fluke 9173-B-R256 Field Metrology Well with Built-in Reference Thermometry B 9173-INSB Comparison Holes
9173-C-R-256 Fluke 9173-C-R-256 Field Metrology Well with Built-in Reference Thermometry C 9173-INSC 0.25-inch Holes
9173-D-R-256 Fluke 9173-D-R-256 Field Metrology Well with Built-in Reference Thermometry D 9173-INSD Metric Comparison Holes
9173-DW-R-256 Fluke 9173-DW-R-256 Field Metrology Well with Built-in Reference Thermometry DW N/A **INDICATES THAT A DISC IS NOT INCLUDED**
9173-E-R-256 Fluke 9173-E-R-256 Field Metrology Well with Built-in Reference Thermometry E 9173-INSE Metric Misc Holes with 0.25-inch Ref Hole
9173-F-R-256 Fluke 9173-F-R-256 Field Metrology Well with Built-in Reference Thermometry F 9173-INSF Metric Comparison Misc Holes with 0.25-inch Ref Hole
For a visual indication of how these discs will appear, please see the attached datasheet listed under 'Technical Specifications'.

Unlike its sister product, the Fluke 9173-X-256 Field Metrology Well, this instrument includes integrated reference thermometry which allows it to accept and read 100Ω, 25Ω and 10Ω PRTs. It is compatible with all of Fluke’s PRTs and is able to accept unique ITS-90 characterisation coefficients from these instruments, thereby allowing the Fluke 9173-X-R-256 Field Metrology Well to utilise the accuracy of PRTs. It is able to read PRTs to an accuracy of up to ±0.011°C (dependent on temperature and probe type) and is supplied with an accredited, traceable calibration.

As standard the Fluke 9173-X-R-256 Field Metrology Well is calibrated using traceable, accredited PRTs, this helps to both limit hysteresis to 0.07°C and maintain the instrument’s display accuracy of ±0.25°C (at 700°C). The inclusion of Fluke’s patent-pending proprietary electronics and dual-zone control (digital and analogue) also helps to maintain its display accuracy and repeatability, as well as limit temperature gradients and loading effects.

These two features, combined with the instrument’s 203mm-deep well, reduce loading effects to between ±0.02°C and ±0.04°C (depending upon the generated temperature). The depth of this well also ensures that the calibrator is able to produce a homogeneous temperature zone of 60mm (from the bottom of the well) and is able to maintain an axial uniformity of ±0.1°C to ±0.25°C, and radial uniformity of ±0.01°C to ±0.04°C. In addition to this, it is able to offer a heat stability of between ±0.005°C and ±0.03°C (dependent on temperature).

The depth of the instrument’s well also contributes to the accuracy of calibration procedures, as it facilitates the complete immersion of the instrument-under-investigation, thereby ensuring that all the instrument's characteristics, including the location and size of the sensor, the width and thermal mass of the probe, as well as any external leads, are accounted for during the calibration.

With the inclusion of all these features, the Fluke 9173-X-R-256 Field Metrology Well is complaint with the six critical components of performance detailed in the European Metrology Community’s EA 10-13 document:

  • Calibrated display accuracy
  • Stability
  • Axial uniformity
  • Radial uniformity
  • Loading effects
  • Hysteresis

Therefore, the Fluke 9173-X-R-256 Field Metrology Well is able to provide the operator with the stability, accuracy and uniformity of a bath temperature calibrator but with all the convenience and practicality of a dry well tester.

The Fluke 9173-X-R-256 Field Metrology Well's design is modelled after that of dry well calibrators; it is lightweight, compact and rugged and can be used in a variety of industrial and hard-to-access environments.

Adding to this instrument’s practicality and expanding its scope-for-use is the inclusion of an RS-232 interface and Fluke’s Interface-It Software. These components facilitate the user’s ability to operate the Fluke 9173-X-R-256 Field Metrology Well remotely from his/her PC. The user is able to view calibration results via his/her PC and can access and adjust the metrology well’s features, functions and settings in order to run calibration procedures remotely.

In addition to this, the Fluke 9173-X-R-256 Field Metrology Well can be used with Fluke’s MET/ TEMP II Software (NOT included) to perform automated calibrations of RTDs, thermocouples and thermistors.

Alternatively, the user can configure the instrument via its front panel utilising the large, LCD display; on-screen menus and a numeric keypad to make adjustments. The Fluke 9173-X-R-256 Field Metrology Well includes four pre-programmed calibration tasks into which the user may enter up to eight temperature set-points with ‘ramp and soak’ times between each point. He/she can also access the Switch Test protocol, optimised for zeroing-in on ‘dead-bands’ for thermal switches.

Via the large, LCD display the user can view the block temperature, cut-out temperature, reference thermometer temperature, stability criteria and ramp rate. He/she may also set the menus to display in English, French or Chinese and can choose to view measurements in °C or °F using the dedicated function button.

This selection of features and functions along with the Fluke 9173-X-R-256 Field Metrology Well with Built-in Reference Thermometry’s sophisticated design makes it ideal for accurately calibrating temperature sensing instruments at high temperatures.

Fluke 9173-X-R-256 Field Metrology Well w/ Reference Thermometry Key Features

  • Calibrate temperature sensing  instruments such as thermometers, temperature probes and thermal switches
  • Temperature range of 50°C to 700°C
  • Available in six models with different disc inserts
  • Integrated reference thermometry allows the instrument to accept and read 100Ω, 25Ω and 10Ω PRTs
  • Compatible with all of Fluke’s PRTs
  • Can accept the unique ITS-90 characterisation coefficients of PRTs in order to utilise their accuracies
  • Able to read PRTs to an accuracy of ±0.011°C (dependent on temperature and probe type)
  • Integrated reference thermometry is supplied with an accredited, traceable calibration
  • Hysteresis: 0.07°C
  • Display accuracy: ±0.25°C at 700°C
  • Includes Fluke’s patent-pending proprietary electronics
  • Dual-zone control (analogue and digital)
  • 203mm-deep well
  • Loading effects: ±0.02°C to ±0.04°C (dependent on temperature)
  • Homogenous temperature zone of 60mm (from the bottom of the well)
  • Axial uniformity: ±0.1°C to ±0.25°C (dependent on temperature)
  • Radial uniformity: ±0.01°C to ±0.04°C (dependent on temperature)
  • Stability: ±0.005°C to ±0.03°C (dependent on temperature)
  • Well depth ensures that instruments-under-investigation are completely immersed
  • Compliant with the six components of performance detailed in the EA-10/13 document
  • Provides the stability, uniformity and accuracy of a bath temperature calibrator
  • Offers the convenience and practicality of a dry well tester
  • Lightweight, compact, rugged design
  • Optimised for use in industrial and/or hard-to-access environments
  • RS-232 interface
  • Supplied with Fluke’s Interface-It Software
  • Interface and supplied software can be used to operate the instrument and view results remotely from the user’s PC
  • Can be used with Fluke’s MET/ TEMP II Software (NOT included)
  • Large, LCD display
  • Numeric keypad
  • On-screen menus
  • Four pre-programmed calibration tasks into which the user can enter up to eight temperature set-points with ‘ramp and soak’ times between each point
  • Switch Test protocol optimised for zeroing-in on ‘dead-bands’ for thermal switches
  • View the block temperature, cut-out temperature, reference thermometer temperature, stability criteria and ramp rate via the display
  • Menus can be displayed in English, French or Chinese
  • Function button for selecting between °C and °F measurement units
  • Ideal for accurately calibrating temperature sensing instruments at high temperatures

What’s Included?

  • Your Choice of Fluke 9173-X-R-256 Field Metrology Well with Built-in Reference Thermometry
  • Fluke Model 9930 Interface-It Software

Fluke 9173-X-R-256 Field Metrology Well with Built-in Reference Thermometry Technical Specifications

The Fluke 9173-X-R-256 Field Metrology Well with Built-in Reference Thermometry is part of Fluke's series of 971X Metrology Wells. Please find the technical specifications for all the models included in this series. 

Specifications 9170 9171 9172 9173
Range
(at 23 °C ambient)
–45 °C to 140 °C
(–49 °F to 284 °F)
–30 °C to 155 °C
(–22 °F to 311 °F)
35 °C to 425 °C
(95 °F to 797 °F)
50 °C to 700 °C†
(122 °F to 1292 °F)
Display Accuracy ± 0.1 °C full range ± 0.1 °C: 35 °C to 100 °C
± 0.15 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
± 0.2 °C: 50 °C to 425 °C
± 0.25 °C: 425 °C to 660 °C
Stability ± 0.005 °C full range ± 0.005 °C: 35 °C to 100 °C
± 0.008 °C: 100 °C to 225 °C
± 0.01 °C: 225 °C to 425 °C
± 0.005 °C: 50 °C to 100 °C
± 0.01 °C: 100 °C to 425 °C
± 0.03 °C: 425 °C to 700 °C
Axial Uniformity
(60 mm)
 
± 0.1 °C at –45 °C
± 0.04 °C at –35 °C
± 0.02 °C at 0 °C
± 0.07 °C at 140 °C
± 0.025 °C at –30 °C
± 0.02 °C at 0 °C± 0.07 °C at 155 °C
 
± 0.05 °C: 35 °C to 100 °C
± 0.1 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
 
± 0.1 °C: 50 °C to 100 °C
± 0.25 °C: 100 °C to 425 °C± 0.4 °C: 425 °C to 700 °C
Radial Uniformity
 
± 0.01 °C full range ± 0.01 °C: 35 °C to 100 °C
± 0.02 °C: 100 °C to 225 °C
± 0.025 °C: 225 °C to 425 °C
± 0.01 °C: 50 °C to 100 °C
± 0.025 °C: 100 °C to 425 °C
± 0.04 °C: 425 °C to 700 °C
Loading Effect
(with a 6.35 mm
reference probe and
three 6.35 mm probes)
± 0.02 °C at –45 °C
± 0.005 °C at –35 °C
± 0.01 °C at 140 °C
± 0.005 °C at –30 °C
± 0.005 °C at 0 °C
± 0.01 °C at 155 °C
± 0.01 °C full range ± 0.02 °C at 425 °C
± 0.04 °C at 700 °C
Hysteresis 0.025 °C 0.04 °C 0.07 °C
Well Depth 160 mm (6.3 in) 203 mm (8 in)
Resolution 0.001 °C
Display LCD, °C or °F, user-selectable
Key Pad Ten key with decimal and +/- button. Function keys, menu key, and °C / °F key.
Cooling Time
 
44 min: 23 °C to –45 °C
19 min: 23 °C to –30 °C
19 min: 140 °C to 23 °C
30 min: 23 °C to –30 °C
25 min: 155 °C to 23 °C
220 min: 425 °C to 35 °C
100 min: 425 °C to 100 °C
235 min: 700 °C to 50 °C
153 min: 700 °C to 100 °C
 
Heating Time 32 min: 23 °C to 140 °C
45 min: –45 °C to 140 °C
44 min: 23 °C to 155 °C
56 min: –30 °C to 155 °C
27 min: 35 °C to 425 °C 46 min: 50 °C to 700 °C
Size (HxWxD) 366 x 203 x 323 mm (14.4 x 8 x 12.7 in)
Weight 14.2 kg (31.5 lb) 15 kg (33 lb) 13.2 kg (29 lb) 15 kg (33 lb)
Power 115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 550 W
115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 1025 W
Computer Interface RS-232 Interface with 9930 Interface-it control software included
Traceable Calibration
(NIST)
Data at –45 °C, 0 °C, 50 °C, 100 °C, and 140 °C Data at –30 °C, 0 °C, 50 °C, 100 °C, and 155 °C Data at 100 °C, 150 °C, 250 °C, 350 °C, and 425 °C Data at 100 °C, 200 °C, 350 °C, 500 °C, and 660 °C
†Calibrated to 660 °C; reference thermometer recommended at higher temperatures.
Built-in Reference Input
Temperature Range –200 °C to 962 °C (–328 °F to 1764 °F)
Resistance Range 0 Ω to 400 Ω, auto-ranging
Characterizations ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen (CVD): R0, a, b, d
Resistance Accuracy 0 Ω to 20 Ω: 0.0005 W
20 Ω to 400 Ω: 25 ppm
Temperature Accuracy
(does not include probe uncertainty) 
10 Ω PRTs: ± 0.013 °C at 0 °C
± 0.014 °C at 155 °C
± 0.019 °C at 425 °C
± 0.028 °C at 700 °C
25 Ω and 100 Ω PRTs: ± 0.005 °C at –100 °C
± 0.007 °C at 0 °C
± 0.011 °C at 155 °C
± 0.013 °C at 225 °C
± 0.019 °C at 425 °C
± 0.027 °C at 661 °C
Resistance Resolution
 
0 Ω to 20 Ω: 0.0001 Ω
20 Ω to 400 Ω: 0.001 Ω
Measurement Period 1 second
Probe Connection 4-wire with shield, 5-pin DIN connector
Calibration NVLAP accredited (built-in reference input only), NIST-traceable calibration provided
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 9173-X-R-256 Field Metrology Well w/ Reference Thermometry
Your Rating
Additional Information
SKU Fluke 9173-X-R-256
Manufacturer Part Code 3016072

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry