All Fluke Products

Fluke ii910 Precision Acoustic Imager

SKU
FLK-II910
Rating:
0%
(0)
Reward Points
:
16995
£20,394.00 £16,995.00
Only 1 in Stock
Free UK Delivery*
Choose a Special Offer
  • PASS Power Bank & Magnetic Wireless Charger
    PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W)
    FREE
    £49.00
  • PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W) SKU: (PASSPOWER-PLUS)
    FREE
    £49.00
    PASS Power Bank & Magnetic Wireless Charger
    • Supports magnetic wireless charging
    • Supports wired charging
    • 10 000mAh 15W
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
FREE Power Bank Wireless Charger
Fluke ii910 Sonic Industrial Imager

Request a demonstration

Pass Presents the Fluke ii910 Acoustic Imager

Fluke ii900 & ii910 Sonic Imager: Must Have Acoustic Leak Detection

The Fluke ii910 Precision Acoustic Industrial Imager is a handheld, easy-to-use, ultrasonic camera that can be used to locate partial discharge in power distribution systems and high-voltage equipment, as well as, leaks in compressed air, gas, steam and vacuum systems.

The Fluke ii910 Sonic Industrial Imager is more sensitive than its predecessor the, Fluke ii900. It has a frequency range of 2kHz to 100kHz and a detection range of up to 120m. This means that it can identify leaks that are both smaller and further away; it also makes it especially well suited to locating partial discharge from a safe distance.

The Fluke ii910 Acoustic Camera is ideal for inspecting and scanning for PD:

  • Insulators,
  • Transformers,
  • Switch gears
  • High-voltage powerlines
  • Arrestors
  • Busbars
  • High Voltage coils
  • Beakers
  • Capacitors

The Fluke ii910 Sonic Industrial Imager can be used to locate faults earlier allowing professionals to take corrective action sooner, thereby limiting damage, maximising uptime, and preventing injury or fatality.

Multiple minuscule microphones capture ultrasonic sound which is converted into a SoundMap™ by the Fluke ii910 Sonic Industrial Imager’s SountSight™ technology. The SoundMap is superimposed onto the visual image allowing the user to pinpoint problems quickly and simply. Moreover, the background noise is automatically filtered out of the SoundMap depending on the frequency range selected.

Images are displayed on the Fluke ii910 Acoustic Industrial Imager’s 7-inch, 1280 x 800 LCD with a simple-to-use touchscreen interface. This easy-to-use acoustic camera requires minimal training to operate and can be easily integrated into existing maintenance routines.

The Fluke ii910 Sonic Industrial Imager is ideal for manufacturers, high-voltage electricians, electrical test engineers, and grid maintenance teams.

Onboard Quantification & Reporting Tools

Like its sister product, the Fluke ii900 Acoustic Imager, the Fluke ii910 includes a LeakQ mode. It also offers a PDQ mode and MecQ mechanical scanning.

LeakQ Mode

Prioritise leak repairs based on their severity using the LeakQ mode. This function quantifies both the distance to and the size/rate of the leak. LeakQ images can be uploaded to Fluke’s reporting tool to determine the estimated cost of the leak, i.e., the expense accrued due to the rate of wasted resources.

Fluke LeakQ™ mode on ii900 Acoustic Imager

PDQ Mode

Similarly, the PDQ mode, unique to the Fluke ii910, calculates the distance to and classifies the type of partial discharge. Images captured in this mode can also be used with Fluke’s online tool to create reports.

MecQ Mechanical Scanning

MecQ mechanical scanning allows you to pinpoint mechanical failings, such as bearings wear, from a safe distance. It can be used to narrow down the areas with potential mechanical problems. MecQ Mechanical Scanning can be used in three sub-modes:

  • 30Hz
  • User-selectable (2-100kHz)
  • Fixed Multi-Mode (15, 20, 30, 40, 60 kHz)

Fluke ii910 Precision Acoustic Imager with MecQ Mode

Fluke Demo

Fluke ii910 Precision Acoustic Imager Key Features

  • A handheld, easy-to-use ultrasonic Acoustic camera
  • Locate partial discharge in power distribution systems and high-voltage equipment
  • Locate leaks in compressed air, gas, steam and vacuum systems
  • Frequency range: 2kHz to 100kHz
  • Detection range: 120m
  • Can detect leaks that are both smaller and further away
  • Inspect insulators, transformers, switchgear and high-voltage powerlines from a safe distance
  • Locate faults earlier
  • Limit damage
  • Maximise uptime
  • Prevent injury or fatality
  • Multiple minuscule microphones
  • SoundSight™ technology: converts sound into a SoundMap which is superimposed onto the visual image
  • Background noise is filtered out of the SoundMap depending on the frequency range selected
  • 7-inch, 1280 x 800 LCD
  • Simple-to-use touchscreen interface
  • Minimal training required
  • Easily integrated into existing maintenance routines
  • Ideal for high-voltage electricians, electrical test engineers, grid maintenance teams and manufacturers

What’s Included?

  • Fluke ii910 Precision Acoustic Industrial Imager
  • AC Power Supply and Battery Pack Charger with Universal AC Adapters
  • 2x Rugged Lithium-ion Battery Packs
  • USB Cable
  • Hard Carrying Case
  • Adjustable Hand Strap and Neck Strap

Fluke ii910 Sonic Industrial Imager Technical Specifications 

Specifications ii910 ii900 Definitions 
Sensors
Frequency band 2 kHz to 100 kHz 2 kHz to 52 kHz  
Detection range .5 m to 120 m (1.6 to 393 feet)* 0.5 to > 70 meters (1.6 to > 230 feet)*  
Field of view 63°± 5°  
Nominal frame rate 25 FPS The number of Frames Per
Second (FPS) indicates the
number of times the image
on the screen is refreshed
each second
Built-in Digital Camera (Visible Light)
Field of view (FOV) 63°± 5°  
Focus Fixed lens  
Display
Size 7" LCD with backlight, sunlight readable  
Resolution 1280 x 800 (1,024,000 pixels)  
Touchscreen Capacitive Extremely precise and
quick responding
Acoustic image Yes, SoundMap™ image A SoundMap™ is a visual
map of noise sources using
an acoustical array
Image Storage 
Storage capacity Internal memory with the capacity for 999 picture files and 20 video files  
Image format Blended visual and SoundMap™.JPG or .PNG  
Video format Blended visual and SoundMap™.MP4  
Video length Up to 5 minutes  
Digital export USB-C for data transfer  
Acoustic Measurements 
Measurement range 12.1 dB SPL to 114.6 dB SPL
±1 dB SPL 2 kHz
4.4 dB SPL to 101.2 dB SPL
±2 dB SPL 19 kHz
12.8 dB SPL to 119.2 dB SPL
±1 dB SPL 35 kHz
19.8 dB SPL to 116.1 dB SPL
±3 dB SPL 52 kHz
41.4 dB SPL to 129.0 dB SPL
±1 dB SPL 80 kHz
54.4 dB SPL to 135.5 dB SPL
±1 dB SPL 100 kHz
15.4 dB SPL to 115.2 dB SPL
±1 dB SPL 2 kHz
5.6 dB SPL to 102.5 dB SPL
±2 dB SPL 19 kHz
28.4 dB SPL to 131.1 dB SPL
±1 dB SPL 35 kHz
41.8 dB SPL to 133.1 dB SPL
±3 dB SPL 52 kHz
Sound pressure level
(dB SPL) or acoustic
pressure is the local
pressure deviation from
the ambient–decible and
sound pressure level
Auto max/min dB gain Auto or manual, user selectable  
Frequency band
selection
User selectable through user-made presets or manual entry  
Software
Ease of use Intuitive user interface  
Trend graphs Frequency and dB scale  
Spot markers dB level reading at centre point of the image  
Battery
Batteries (field-replaceable, rechargeable) 2 x Rechargeable Li-ion, Fluke BP291  
Battery life 6 hours/battery (product includes spare battery)  
Battery charging time 3 hours  
Battery charging system External dual-bay charger, EDBC 290  
General Specifications 
Standard palettes 3: Grayscale, Ironbow and Blue-Red  
Operating temperature -10 °C to 40 °C (14 °F to 104 °F) -10 °C to 45 °C (14 °F to 113 °F)  
Storage temperature -20 °C to 70 °C ( -4 °F to 158 °F) without batteries installed  
Relative humidity 10 % to 95 % non-condensing  
Size (H x W x L) 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)  
Weight
(battery included)
1.7 kg (3.75 pounds)  
Ingress Protection (IP) IP40 Protection against particles
1 mm or greater
and dripping water
Warranty 2 year  
Self-diagnostic
notification
Array-health test to identify when microphone array needs attention  
Supported languages Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese  
RoHS compliant Yes
Safety
General Safety IEC 61010-1  
Electromagnetic
Compatibility (EMC)
International
IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
 
Korea (KCC) Class A Equipment (Industrial Broadcasting and Communication)  
USA (FCC 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103  
Note *Depending on ambient conditions  

 

Fluke ii900 & ii910 Sonic Industrial Imager - Datasheet Datasheets Fluke ii900 & ii910 Sonic Industrial Imager - User Manual Manuals & Guides Fluke ii900 & ii910 Sonic Industrial Imager - Quick Reference Guide Manuals & Guides Fluke ii900 & ii910 Sonic Industrial Imager - Product Specifications Technical Specifications Fluke ii900 & ii910 Sonic Industrial Imager - Safety Information Notes & Other Fluke ii900 & ii910 Sonic Industrial Imager - Statement of Memory Volatility Notes & Other

Reviews

Additional Information
SKU FLK-II910
Manufacturer Part Code 5233904
Country of Origin Romania