The Megger CFL535G locates cable faults across virtually any paired metallic cable. Its dual-channel layout and WVGA display make trace interpretation straightforward, while auto set-up handles the initial configuration. The CFL535G has broad velocity-factor support and selectable impedances.
Trace analysis is fast thanks to dual cursors, internal storage for up to 100 traces, and a comparison mode that highlights even subtle changes between two results. Megger's Xpert mode automatically steps through major events on the cable, placing the cursor where you need it with a single button press.
Compact and site-ready, the CFL535G carries an IP54 rating and CAT IV/CAT III safety approvals for dependable field use. When it's time to document your findings, the supplied TraceXpert software provides straightforward data transfer and reporting, turning stored traces into clear, shareable records.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Operational Temperature | 5 ºF to 122 ºF (-15 ºC to 50 ºC) |
|---|---|
| Charging Temperature | 32 ºF to 104 ºF (0 ºC to 40 ºC) |
| Storage Temperature | -4 ºF to 158 ºF (-20 ºC to 70 ºC) |
| Ranges | Up to 20000m with a minimum resolution of 0.1m |
| Accuracy | ±1% of range ± 1 pixel at 0.67VF [Note- The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct] |
| Resolution | 1% of range |
| Input Protection | This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV Fused leads must be used if the voltage between the terminals exceeds 300 V |
| Output Pulse | Up to 20 volts peak to peak into an open circuit. Pulse widths determined by range and cable |
| Gain | Set for each range with user-selectable steps (in Manual operating mode) |
| Velocity Factor | Variable from 0.2 to 0.99 in steps of 0.01 |
| TX Null | Automatic |
| Power Down | User programmable auto power off timer 1, 5, 10 mins or off |
| Batteries | Li-ion rechargeable battery with 12 hours typical life |
| Safety | This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV or 300 V CAT III Fused leads must be used if the voltage between the terminals exceeds 300 V Compliant with EN60950-1, EN61010-3, UN38.3 and EN62133 |
| EMC | Complies with Electromagnetic Compatibility Specifications (Light industrial) BS EN 61326-1, with a minimum performance of 'B' for all immunity tests |
| Mechanical | The instrument is designed for use indoors or outdoors and is rated to IP54 |
| Case Dimensions | 11.4 in. x 7.5 in. x 2.2 in (290 mm x 190 mm x 55 mm) |
| Weight | 3.8 lbs (1.7kg) |
| Case Material | ABS |
| Connectors | Four 4 mm safety terminals and two F connectors Other standard push-on adapters will fit the CFL535G |
| Test Leads | Bed-of-Nails lead set |
| Display | 800 x 480 pixel WVGA colour graphics LCD, viewable in external environments User-selectable colour schemes |
| Except where otherwise stated, this specification applies at an ambient temperature of 68 ºF (20 ºC). | |