The Megger CFL535G locates cable faults across virtually any paired metallic cable. Its dual-channel layout and WVGA display make trace interpretation straightforward, while auto set-up handles the initial configuration. The CFL535G has broad velocity-factor support and selectable impedances.

Trace analysis is fast thanks to dual cursors, internal storage for up to 100 traces, and a comparison mode that highlights even subtle changes between two results. Megger's Xpert mode automatically steps through major events on the cable, placing the cursor where you need it with a single button press.

Compact and site-ready, the CFL535G carries an IP54 rating and CAT IV/CAT III safety approvals for dependable field use. When it's time to document your findings, the supplied TraceXpert software provides straightforward data transfer and reporting, turning stored traces into clear, shareable records.

Key Features

  • Comprehensive Dual Channel capability with dual aspect display
  • Auto set up mode for instant use
  • Ultra-fast pulse for near-end fault identification
  • ip54 rating offers real life working
  • Designed for use on all metallic paired cables
  • Backlit graphics colour LCD (800x480)
  • Adjustable display contrast
  • Resolution to 0.1 m
  • TraceXpert guide to potential fault location
  • 100 trace on board memory
  • USB connection to PC allowing upload and download of traces
  • TraceXpert PC software analysis tool
  • For use on Telecom TNV-3 circuit, or 150V CAT IV power circuits
  • Power blocking filter built-in
  • Environmental protection to IP54
  • Selectable output impedance (25, 50, 75,100 and 125 Ω)
  • 2ns pulse for near end fault location
  • AUTO option selecting gain and pulse for each range
  • AUTO option matches output impedance to cable
  • Display distance in metres or feet
  • Li-ion rechargeable battery (12 hours typical life)

What's Included?

  • CFL535G Time Domain Reflectometer
  • Download kit
  • Bed of nails test leads
  • Carry case
  • User guide CD
  • AC-DC charger
£3,445.00
£4,134.00 inc vat
Free Delivery*
Stock Due: Typically 1-6 Days
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Black Friday Free Gift (Spend £200+) Find Out More

Request a Quote

60 Day Returns
Ask a Question or Price Match
Black Friday Fantastic Deals End In 00days00hrs00mins00secs Shop the Deals How Can We Help? Got a question? Our team's ready to help. Looking for something specific? We carry thousands more products than you see here. Ask Our Experts A Question

Offers

Black Friday Free Gift (Spend £200+)

Get a free gift this Black! Even better, this bonus stacks with any other offer.

  • Spend £200+ get a free Head Torch OR
  • Spend £500+ get a free Digital Tyre Inflator

Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.

Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.

Technical Information
Specification
Operational Temperature 5 ºF to 122 ºF
(-15 ºC to 50 ºC)
Charging Temperature 32 ºF to 104 ºF
(0 ºC to 40 ºC)
Storage Temperature -4 ºF to 158 ºF
(-20 ºC to 70 ºC)
Ranges Up to 20000m with a minimum resolution of 0.1m
Accuracy ±1% of range ± 1 pixel at 0.67VF
[Note- The measurement accuracy is for the indicated cursor position only and is conditional on the velocity factor being correct]
Resolution 1% of range
Input Protection This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV
Fused leads must be used if the voltage between the terminals exceeds 300 V
Output Pulse Up to 20 volts peak to peak into an open circuit. Pulse widths determined by range and cable
Gain Set for each range with user-selectable steps (in Manual operating mode)
Velocity Factor Variable from 0.2 to 0.99 in steps of 0.01
TX Null Automatic
Power Down User programmable auto power off timer 1, 5, 10 mins or off
Batteries Li-ion rechargeable battery with 12 hours typical life
Safety This instrument complies with IEC61010-1 for connection to live systems up to 150 V CAT IV or 300 V CAT III
Fused leads must be used if the voltage between the terminals exceeds 300 V
Compliant with EN60950-1, EN61010-3, UN38.3 and EN62133
EMC Complies with Electromagnetic Compatibility Specifications (Light industrial) BS EN 61326-1, with a minimum performance of 'B' for all immunity tests
Mechanical The instrument is designed for use indoors or outdoors and is rated to IP54
Case Dimensions 11.4 in. x 7.5 in. x 2.2 in
(290 mm x 190 mm x 55 mm)
Weight 3.8 lbs (1.7kg)
Case Material ABS
Connectors Four 4 mm safety terminals and two F connectors
Other standard push-on adapters will fit the CFL535G
Test Leads Bed-of-Nails lead set
Display 800 x 480 pixel WVGA colour graphics LCD, viewable in external environments
User-selectable colour schemes
Except where otherwise stated, this specification applies at an ambient temperature of 68 ºF (20 ºC).
Document Downloads
Megger CFL535G Dual Channel Cable Fault Locator (TDR) Datasheet Datasheet
Megger Time Domain Reflectometers - Applications Manual/Guide
Megger Basic Time Domain Reflectometers Operation Guide Manual/Guide
Additional Information
SKU
1007-069
Manufacturer Part Code
1007-069

Customer Reviews

 
Megger CFL535G Dual Channel Cable Fault Locator (TDR), US
£3,445.00
£4,134.00 inc vat
£3,445.00
£4,134.00 inc vat