Description
SERIES 2 - Special Purpose Dial Indicators
Adjustable-Hand Dial Gauge
- The hand position can be adjusted independently of the position of the plunger by rotating the top knob.
Peak-Hold Dial Gauge
- A mechanism holds the pointer and the plunger at the position of maximum depression and hence displays the maximum value.*
- *Clearance of peak hold: Push the nut in the direction of the arrow indicated in the dimensions diagram for 2046S-80.
Tech Specs
Metric
Max. permissible error | |||||||||
---|---|---|---|---|---|---|---|---|---|
Indication error | |||||||||
SKU | Range (Range/Rev) | 1/10 Rev | 1/2 Rev | 1 Rev | Overall | Hysteresis | Repeatability | Scale | Measuring Force |
Graduation: 0.01 mm | |||||||||
MIT-2048S-10 | 10 mm (1 mm) | 5 µm | 9 µm | 10 µm | 15 µm | 3 µm | 3 µm | 0-100 | 1.4 N or less |
MIT-2046S-80 | — | — | 5.0 N or less |
Note: Completed products inspection is performed in the vertical orientation (contact point downward) and the stated accuracy is guaranteed.
0 Reviews
Overall Rating
Additional Information
SKU | 204XA-10/80 |
---|