All Aim-TTi Products

Aim-TTi TG2000 20MHz DDS Function Generator w/ RS-232 & USB Interfaces

SKU
59130-0500
Rating:
0%
(0)
Reward Points
:
683
£819.60 £683.00
Free UK Delivery*
Advice & Support
Price Match Request
Aim-TTi TG2000 20MHz DDS Function Generator w/ RS-232 & USB Interfaces

The Aim-TTi TG2000 20MHz DDS Function Generator is a digitally controlled waveform generator with RS-232 and USB interfaces. It utilises a direct digital synthesis (DDS) technique to generate waveforms digitally using a phase accumulator, a look-up table, and a DAC. DDS provides high accuracy, stability and spectral purity as well as excellent frequency agility and low phase noise.

The Aim-TTi TG2000 20MHz DDS Function Generator can create sine, square, positive pulse and negative pulse waveforms.

Wide Frequency and Amplitude Range

The Aim-TTi TG2000 20MHz DDS Function Generator has a frequency range of 0.001Hz to 20MHz with a frequency setting resolution of six digits or 1mHz, stability of 1ppm, and an absolute accuracy of 10ppm over one year.

Additionally, the Aim-TTi TG2000 20MHz DDS Function Generator has a variable amplitude range spanning 5mV to 20V peak-to-peak from a source impedance of 50Ω or 600Ω. The waveform quality remains excellent over the entire amplitude range.

Frequency or Period Entry

The frequency parameter can be configured in regards to frequency or period. It can be set numerically using the units of the operator’s choice.

Flexible Amplitude Entry

The Aim-TTi TG2000 20MHz DDS Function Generator’s output impedance can be set to 50Ω or 600Ω and the amplitude can be configured in RMS voltage, dBm or peak-to-peak voltage.

The amplitude can be set in terms of either the voltage into the correct termination, or the source EMF (for high-impedance loads).

Easy to Use

Parameters can be entered numerically using the Aim-TTi TG2000 20MHz DDS Function Generator’s keypad. Alternatively, settings can be incremented or decremented using the rotary encoder which enables quasi-analogue control.

The main information is visible on the Aim-TTi TG2000 20MHz DDS Function Generator’s backlit LCD with four rows of twenty characters. Via the submenus, the user can access complex functions and modulation modes.

Modulation Modes

The Aim-TTi TG2000 20MHz DDS Function Generator supports the following modulation modes.

Sweep

All the Aim-TTi TG2000 20MHz DDS Function Generator’s sweeps are phase continuous. It supports linear, logarithmic, single and continuous sweeps. Single sweeps can be triggered via the front panel, the trigger input or digital interfaces.

Over the course of the sweep, adjustable sweep markers are displayed enabling the user to see frequency points on the scope/ chart recorder.

All waveforms can be swept over their full frequency range (0.2Hz minimum) at an adjustable-rate ranging from 50 milliseconds to 15 minutes.

Gated

The output signal is switched on or off depending on the gating signal state. The Aim-TTi TG2000 20MHz DDS Function Generator’s front panel, internal trigger generator, trigger input or bus interface signal can be used as the gating source.

AM

The Aim-TTi TG2000 20MHz DDS Function Generator supports external amplitude modulation up to 100% for all waveforms via the VCA input.

FSK

The Frequency Shift Keying mode facilitates phase coherent switching between two user-defined frequencies.

The rate of switching is specified by the source; the Aim-TTi TG2000 20MHz DDS Function Generator’s front panel key, internal trigger generator, trigger input socket or bus interface signal can serve as the switching source.

Tone Switching

The user can specify up to sixteen frequencies between which the Aim-TTi TG2000 20MHz DDS Function Generator will switch according to the trigger signal.

Synchronisation

The Aim-TTi TG2000 20MHz DDS Function Generator also includes an auxiliary output socket that can be used to provide the following Sync signals:

  • Waveform Sync: 50% duty cycle square wave at the frequency of the main output
  • Sweep Sync: outputs a pulse at the start of each sweep and at a user-defined marker frequency
  • Trigger Out: issues a replica of the trigger signal from the trigger input socket, the internal trigger/ gate generator or the manual trigger key

Total Digital Control

As the Aim-TTi TG2000 20MHz DDS Function Generator’s frequency and functions are all digitally controlled, this makes it easy for complete instrument setups to be stored and facilitates full remote control.

Non-Volatile Memory

Up to nine complete instrument setups can be saved to the Aim-TTi TG2000 20MHz DDS Function Generator’s non-volatile memory.

The Aim-TTi TG2000 20MHz DDS Function Generator will automatically save the setup upon shut down. The last-used setup or a pre-defined default setup can be restored upon reactivation of the Aim-TTi TG2000 20MHz DDS Function Generator.

RS-232 and USB Interfaces

The Aim-TTi TG2000 20MHz DDS Function Generator’s RS-232 and USB interfaces mean setups can be stored remotely. These interfaces also enable full remote control of the waveform generator’s functions.

The Aim-TTi TG2000 20MHz DDS Function Generator is an economic and easy-to-use waveform generator with an eclectic selection of functions.

Aim-TTi TG2000 20MHz DDS Function Generator Key Features

  • A digitally controlled waveform generator with RS-232 and USB interfaces
  • Direct digital synthesis (DDS) technique generates waveforms digitally using a phase accumulator, a look-up table and DAC
  • High accuracy
  • High stability
  • High spectral purity
  • Excellent frequency agility
  • Low phase noise
  • Sine, square, positive pulse and negative pulse waveforms
  • Frequency range: 0.001Hz to 20MHz
  • Frequency setting resolution: six digits or 1mHz
  • Frequency stability: 1ppm
  • Frequency accuracy: 10ppm over one year
  • Variable amplitude range: 5mV to 20V peak-to-peak from a 50Ω or 600Ω source impedance 
  • Excellent waveform quality over the entire amplitude range
  • Configure the frequency parameter in regards to frequency or period
  • The frequency parameter can be set numerically using the units of the operator’s choice
  • The Amplitude can be set in RMS voltage, dBm or peak-to-peak voltage
  • Configure parameters numerically via the keypad
  • Increment or decrement settings using the rotary encoder which enables quasi-analogue control
  • Backlit LCD with four rows of twenty characters
  • The main information is visible on the display
  • Access complex functions and modulation modes via the submenus
  • Modulation modes: Sweep, Gated, AM, FSK and Tone Switching
  • Sweeps are phase continuous
  • Supports linear, logarithmic, single and continuous sweeps
  • Single sweeps can be triggered via the front panel, the trigger input or digital interfaces
  • Adjustable sweep markers are displayed while the sweep is running
  • All waveforms can be swept over their full frequency range at an adjustable-rate ranging from 50 milliseconds to 15 minutes
  • The auxiliary output supports Waveform Sync, Sweep Sync and Trigger Out
  • The frequency and functions are all digitally controlled
  • Save up to nine complete instrument setups to the non-volatile memory
  • Automatically saves the instrument setup upon shut down
  • Restore the last used setup or a predefined default setup upon startup
  • Store instrument setups remotely using the RS-232 and USB interfaces
  • RS-232 and USB interfaces enable full remote control
  • Economic and easy-to-use waveform generator with an eclectic selection of functions

What’s Included?

  • Aim-TTi TG2000 20MHz DDS Function Generator with RS-232 & USB Interfaces

Aim-TTi TG1000 10MHz DDS Function Generator Technical Specifications 

Note Specifications apply at 18°- 28°C after 1-hour warm-up, at maximum output into 50Ω.
Frequency
Note All waveforms are derived from a crystal clock using Direct Digital Synthesis.
Frequency Range 1mHz to 20MHz
Resolution 6 digits or 1mHz
Accuracy ±10ppm for 1 year, 18°C to 28°C; ±1mHz below 0.2Hz
Tempco Typically <1ppm/°C outside of 18°C to 28°C
Waveforms
Sinewave Range 1mHz to 20MHz
Resolution 6 digits or 1mHz
Distortion <0.3% THD to 20kHz (typically 0.1%), <-45dBc to 300kHz, <-35dBc to 20MHz (typically <-40dBc)
Spurii Non harmonically related spurii <-55dBc to 1MHz, <(-55dBc + 6dB/octave) 1MHz to 20MHz
Output Level 5mV to 20V pk-pk from 50Ω or 600Ω
Squarewave Range 1mHz to 10MHz
Resolution 6 digits or 1mHz
Symmetry variable 20% to 80% in 1% steps
Aberrations <5% + 2mV
Rise & Fall Times <22ns
Output Level 5mV to 20V pk-pk from 50Ω or 600Ω
Triangle  Range 1mHz to 1MHz
Resolution 6 digits or 1mHz
Linearity error <0.5% to 100kHz
Output Level 5mV to 20V pk-pk from 50Ω or 600Ω
Positive and Negative Pulse  Range 1mHz to 20MHz
Resolution 6 digits or 1mHz
Symmetry variable 20% to 80% in 1% steps
Aberrations <5% + 2mV
Rise & Fall Times <22ns
Output Level 2.5mV to 10V pk-pk from 50/600Ω positive or negative only pulses with respect to the DC Offset baseline
Modulation Modes 
Continuous Note Continuous cycles of the selected waveform are output at the selected frequency
Gated  Note Non-phase-coherent signal keying - output is On while Gate signal is high and Off while low.
Carrier frequency  From 0.1Hz to 20MHz
Carrier waveforms All
Trigger rep. rate dc to 100kHz external, dc to 5kHz internal
Gate source Front panel MAN TRIG key, Internal Gate Generator,
TRIG/GATE input, or Remote Interface
Sweep Carrier waveforms All
Sweep Mode Linear or logarithmic, single or continuous
Sweep Width 0.2Hz to 20MHz in one range. Phase continuous.
Independent setting of the start and stop frequency
Sweep Time 50ms to 999s (3 digit resolution)
Markers Available from AUX output. Variable during sweep
Sweep Trigger Source  The sweep may be free run or triggered from: front panel MAN TRIG key, TRIG/GATE input
Amplitude Modulation  Carrier frequency 1mHz to 20MHz
Carrier waveforms All
Modulation source VCA IN socket
Frequency Shift Keying (FSK) Note Phase coherent switching between two selected frequencies at a rate defined by the switching signal source.
Carrier frequency 1Hz to 20MHz
Carrier waveforms All
Switch rate dc to 5kHz (internal), dc to 1MHz (external)
Switching signal source Front panel MAN TRIG key, Internal Trigger Generator, TRIG/GATE input or Remote Interface 
Tone  Note The tone is output while the trigger signal is high, and stopped when the trigger signal
is low. The next tone is output when the trigger signal goes high again.
Carrier waveforms All
Frequency list Up to 16 frequencies between 1Hz and 20MHz
Min. switching time 1ms per tone
Switching source Front panel MAN TRIG key, Internal Trigger Generator, TRIG/GATE input or Remote Interface
Internal Trigger/ Gate Generator  Period 0.2ms to 999s (resolution 0.2 ms)
Waveform Square wave (1:1 duty cycle)
Main Output 
Output Impedance 50Ω or 600Ω switchable
Amplitude

5mV to 20V pk-pk open circuit (2.5mV to10V into 50Ω/600Ω)

Output can be specified as V-HiZ (open circuit value) or V (potential difference) in pk-pk, RMS or dBm. Note that in positive or negative Pulse modes the amplitude range is 2.5mV to 10V pk-pk O/C.

Accuracy ±3% ±1mV at 1kHz into 50Ω/600Ω
Flatness ±0.2dB to 500kHz; ±1dB to 10MHz;  ±2dB to 20MHz
DC Offset ±10V from 50Ω/600Ω. DC offset plus signal peak limited to ±10V. Accuracy ±3% ±10mV
Resolution 3 digits for both amplitude and offset
Auxiliary Output 
Note Multi-function output user-definable to be any of the following
Waveform Sync Outputs a 50% duty cycle squarewave at the main waveform frequency
Trigger Out Outputs a replica of the current trigger signal
Sweep Sync Outputs a trigger signal at the start of sweep (for synchronising an oscilloscope or chart recorder). Can additionally output a sweep marker.
Signal Levels Output Impedance 50Ω nominal. Logic levels of <0.8V and
>3V. Sweep Sync is a 3 level waveform, low at start of sweep, high at end of sweep, with a narrow 1V pulse at the marker point
Inputs 
Ext Trig/Gate Frequency Range DC to 1MHz for FSK; DC to 100kHz for Gate; DC to 2.5kHz for Tone and Sweep
Signal Range Nominal TTL level threshold; maximum input ±10V
Min. Pulse Width 100ns for Gate/FSK; 0.2ms for Sweep and Tone
Input Impedance Typically 10kΩ
VCA In  Frequency Range DC - 100kHz
Signal Range 2.5V for 100% level change at maximum output
Input Impedance Typically 6kΩ
Interfaces     
Note Full remote control facilities are available through the RS232 or USB interfaces
RS232 Variable Baud rate (19200 max), 9-pin D-connector. As well as operating in a conventional RS-232 mode the interface can be operated in addressable mode whereby up to 32 instruments can be addressed from one RS-232 port
USB Standard USB hardware connection. Conforming USB 1.1
General 
Display 20 character x 4 row alphanumeric LCD
Data Entry Keyboard selection of mode, waveform etc.; value entry direct by numeric keys or by rotary control.
Stored Settings Up to 9 complete instrument set-ups may be stored in battery-backed memory
Size & Weight 260(W) x 88(H) x 235(D) mm; 2kg (4.5lb)
Power 100V, 110-120V or 220-240V ±10% 50/60Hz, adjustable internally. 40VA max. Installation Category II.
Operating Range +5°C to 40°C, 20-80% RH
Storage Range -20°C to +60°C
Environmental Indoor use at altitudes up to 2000m, Pollution Degree 2
Safety & EMC Complies with EN6010-1 and EN61326
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Aim-TTi TG2000 20MHz DDS Function Generator w/ RS-232 & USB Interfaces
Your Rating
Additional Information
SKU 59130-0500
Manufacturer Part Code 59130-0500
International Enquiry