Capable of measuring an array of electrical parameters, the Chauvin Arnoux CA5293 Digital Multimeter is an ergonomic, easy-to-use DMM with an accuracy of 0.02% (maximum), a 200kHz bandwidth, and a range of analytical tools.
The Chauvin Arnoux CA5293 Digital Multimeter can measure the following electrical parameters:
- AC/DC voltage
- AC/DC true-RMS current
- Frequency
- Resistance
- Continuity
- Temperature
- Diode
It features useful analytical and recording features such as date- and time-stamping, Min, Max, Avg and Peak monitoring, filtering, and duty cycle, as well as zoom, trace, and cursor tools.
Measurements are indicated on the Chauvin Arnoux CA5293 Digital Multimeter’s multi-parameter, graphical display with a 320x240px colour matrix screen with a black background. Waveforms up to 600Hz are shown on the display; trends are also indicated on the summary screen.
You can save up to 30 sequences and 30 000 measurements to the Chauvin Arnoux CA5293 Digital Multimeter’s memory. A USB interface facilitates data download to a PC/ laptop. Once downloaded, readings can be evaluated using Chauvin Arnoux’s SX-DMM PC Software. Models with optional Bluetooth connectivity can also transfer data wirelessly to a smartphone/ tablet with the Chauvin Arnoux App installed.
Finally, the Chauvin Arnoux CA5293 Digital Multimeter has been ergonomically designed: it is compact, rugged, and watertight (IP67). The Chauvin Arnoux CA5293 Digital Multimeter has a safety rating of 1000V CAT III/ 600V CAT IV. Moreover, it offers a maximum battery life of 4.5 hours and can be operated whilst charging, allowing you to maximise uptime.
Portable, practical, and precise, the Chauvin Arnoux CA5293 Digital Multimeter is a DMM ideal for professionals.
Chauvin Arnoux CA5293 Digital Multimeter Key Features
- A compact, rugged, watertight instrument
- Available with or without Bluetooth
- Suitable for measuring a variety of electrical parameters
- AC/DC voltage
- AC/DC true-RMS current
- Frequency
- Resistance and continuity
- Capacitance
- Temperature
- Diode test
- Date- and time-stamping
- Min/Max/Avg and Peak Monitoring
- Filtering
- Duty cycle
- Multi-parameter, graphical display
- 320x240px colour matrice screen with a black background
- Waveforms up to 600Hz are displayed on the screen
- Trends are shown on the summary screen
- Accuracy: up to 0.02%
- 100 kHz bandwidth
- Save up to 30 sequences and 30 000 measurements
- Zoom, trace, and cursor tools
- USB interface
- Optional Bluetooth: wirelessly communicate readings to Android smartphones/ tablets with the Chauvin Arnoux App installed
- Ergonomic
- IP67
- 1000V CAT III/ 600V CAT IV
- Battery life: 100 hours
- Can be operated while charging
- A portable, practical, precise DMM
What’s Included?
- Your Choice of Chauvin Arnoux CA5293 Digital Multimeter with or without Bluetooth
- 4 x 1.5V NiMH Rechargeable Batteries
- 5m Straight/ Straight Red Cable
- 5m Straight/ Straight Black Cable
- Red CAT IV 1kV Test Probe
- Black CAT IV 1kV Test Probe
- USB Optical Communication & SX-DMM Software
- USB Charger & USB Connection Cable
- CD with User Manual
- Multilingual Start-up Guide
- Case
Chauvin Arnoux CA5292 & CA5293 Digital Multimeters Technical Specifications
Specifications | CA 5292 | CA 5293 |
DC, AC and AC+DC voltages | TRMS | |
Range | 100 mV */ 1000 mV / 10 V / 100 V / 1000 V | |
Resolution | 1 μV / 10 μV / 0.1 mV / 1 mV / 10 mV | |
AC and AC+DC bandwidth | 100 kHz | 200 kHz |
DC accuracy | 0.03% | 0.02% |
AC and AC+DC (VLowZ) accuracy | 0.3% | 0.3% |
DC, AC and AC + DC TRMS current | ||
Range | 1000 μA / 10 mA / 100 mA / 1000 mA / 10 A / 20 A (30s max on 100 A range) | |
Resolution | 10 nA / 0.1 μA / 1 μA / 10 μA / 100 μA / 1000 μA | |
DC / AC and AC+DC accuracy | 0.08% / 0.3% | |
AC and AC+DC bandwidth | 50 kHz | |
Frequency | ||
Frequency range | 10 Hz / 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz / 5 MHz | |
Resolution | 0.0001 Hz / 0.001 Hz / 0.01 Hz / 0.1 Hz / 1 Hz / 10 Hz / 100 Hz | |
Resistance and continuity | ||
Ranges | 100 Ω */ 1 kΩ / 100 kΩ / 1000 KΩ / 10 MΩ / 100 MΩ | |
Resolution | 0.001 Ω / 10 mΩ / 100 kΩ / 10Ω / 10Ω / 1 kΩ | |
Basic accuracy | 0.07% | |
Protection | 1000 V electronic protection | |
Audible continuity detection | 1000 Ω / SIGNAL <20 Ω < 3.5 V | |
Diode test | ||
Threshold voltage measurement | Diode 0 -2.6 V <1 mA + Zener diode or LED 0-2.6 V <11 mA | |
Capacitance | ||
Ranges | 1 nF / 10 nF / 100 nF / 1000 nF / 10 μF / 100 μF / 1 mF / 10 mF | |
Resolution* | 1 pF / 10 pF / 0.1 nF / 1 nF / 0.01 μF / 0.1 μF / 1 μF / 10 μF | |
Temperature with Pt100/1000 and K/J thermocouples | ||
Operating range | -200 °C to +800° C with Pt and -40 to +1200 °C with K thermocouple | |
Accuracy | 0.1 % | |
Other Measurement functions | ||
SURV MAX/MIN/AVG | Time/date-stamped on all the main positions | |
REL | Reference-delta relative value on 3 displays + main measurement | |
PWM filter | 4th order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors | |
SPEC | Display of the measurement tolerance + Smin + Smax | |
GRAPH | Trends of main measurements with max., variable time and display of waveform (50/60 and 600 Hz) | |
Secondary measurements | 3 measurements + main measurement | |
Measurement storage | 10,000 | 30,000 |
*manual access | ||
General Specifications | ||
Type of display | Colour graphical (70x52) with backlighting and black background on 4 x 100,000-count displays | |
PC interfaces | Optical USB connector or Bluetooth (option)– SX-DMM software and ANDROID application | |
Power supply | USB-type charger or 4 AA batteries or NiMH rechargeable batteries | |
Safety / EMC | Safety as per IEC 61010-1, IEC 61010-2-033 1000 V-CAT III /600 V CAT IV EMC as per EN 61326-1 |
|
Environment | Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C | |
Mechanical specifications | Dimensions (L x W x H): 196x90x47.1 mm – Weight: 570 g | |
Warranty | 3 years |
SKU | CA5293-X |
---|