The FLIR T912406 is designed to verify the accuracy of FLIR acoustic imaging cameras. It produces a sound signal that the camera detects and analyses. The signal’s dB level helps confirm both the accuracy of the readings and the condition of the microphone array. Inside the acoustic camera tester are sound samples that match the camera’s operating modes, allowing demonstrations that replicate various types of partial discharges, common gas leaks, and mechanical fault noises.
Worth £29.99. Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.
| Acoustic | |
|---|---|
| Frequency Range | 2 kHz to 90 kHz |
| Modes of Operation | Calibration - Test signal for checking the accuracy of the acoustic
cameras PD1 - Corona discharge sound PD2 - Floating discharge sound PD3 - Surface discharge sound Leak - Compressed gas leak sound Mech - Mechanical fault sound |
| Physical Data | |
| Power Input | Input voltage: 12 - 18 VDC Nominal input: 14.6 VDC, 2 A max |
| Weight | 273 g (0.6 lb) |
| Size (L x W x H) | 160 x 80 x 70 mm (6.3x 3.1 x 2.8 in) |
| Tripod Mounting | Quick-release mount |
| Environmental Data | |
| Operating Temperature | -10°C - +40°C (14°F - 104°F) |
| Humidity | Recommended 0-90% (Non-Condensing) |
| Protection Class | IP40 |
| Power Supply Data | |
| Input Voltage Range | 90 - 264 VAC |
| Input Current | 1.3 A max @ 100 - 240 VAC |
| AC Inlet | IEC 320 C8 AC Inlet |
| Output Voltage | 8 - 14.6 VDC |
| Output Current | 4.0 A max |
| Output Power | 58.4 W max |
| Operating Temperature | -20°C - +45°C (-4°F - 113°F) |
| Humidity | 10-90% r.H. |
| Power Supply Size | 96 x 46 x 33 mm (3.77 x 1.81 x 1.29 in) |
| Power Supply Weight | 250 g (0.55 lb) without input cable |