The camera wirelessly connects to the FLIR Responder App. Setup, media management, and streaming are all available in the app. Departments can also document operations, conduct training, and share critical visuals. The Search and Detection Modes also help firefighters quickly identify hotspots, locate victims, and anticipate dangerous fire behaviour.
Call 01642 931 329 or complete the form:
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Imaging and Optical Data | |
|---|---|
| IR Resolution | 640 x 480 |
| Thermal Sensitivity, NETD | <70 mK @ 30°C (86°F) over entire range |
| Field of View | 53° × 40° |
| Image Frequency | 30 Hz |
| Spectral Range | 7.5 to 14 μm |
| Pixel Pitch | 12 μm |
| Detector Type | Focal plane array (FPA), uncooled microbolometer |
| Image Representation | |
| Display | 4" LCD, 640 × 480, backlit |
| Display Frame Rate | 60 Hz |
| Temperature Range | Single range |
| Contrast Optimisation | Digital enhancement, Flexible Scene Enhancement (FSX) |
| Image Modes | Basic, Search, Detection, High Heat, White Hot |
| Zoom | 2x digital zoom |
| Measurement | |
| Object Temperature Range | Single range solution operating: -20°C to 650°C (-4°F to 1202°F) |
| Accuracy | ±4°C (±7.2°F) or ±6% of reading, for ambient temperature 10°C to 35°C (50°F to 95°F) |
| Video and Images | |
| Storage Media | Internal flash memory |
| Image Storage Formats | Standard JPEG |
| Media Gallery | Camera and Flir Responder app |
| Image Storage Capacity | 200 files in total (N.B. The total number of files varies depending on the number of saved video clips.) |
| Non-radiometric IR Video Recording | MPEG4 to internal flash memory |
| Non-radiometrics IR Video Streaming | Uncompressed colourised video using USB and MPEG-4 Stream over Wi-Fi to the FLIR Responder app |
| Data Communication Interfaces | |
| Interfaces | Update via OTA (Wi-Fi using the Flir Responder
app) Legacy support for updates from PC and data transfer to and from PC |
| USB | USB-C |
| Wi-Fi | IEEE 802.11 b/g/n (2.4 GHz) |
| Bluetooth | Bluetooth v. 5.0 EDR + BLE, *PAN |
| Power System | |
| Battery Type | Li-Ion |
| Battery Voltage | 3.7 V |
| Battery Capacity | 5.8 Ah, at 20°C to 25°C (68°F to 77°F) |
| Battery Operating Time | Up to 4 hours @ 25°C (77°F) ambient temperature and typical use |
| Charging System | The battery is charged inside the camera 2-bay charger Optional in-truck charger |
| Charging Time | <3 h to capacity enough for 3 h operation |
| Charging Temperature | 0°C to 45°C (32°F to 113°F) |
| Power Options | Automatic shutdown and sleep mode |
| Environmental Data | |
| Operating Temperature Range | 150°C (302°F): 15 min 260°C (500°F): 5 min |
| Storage Temperature Range | -40°C to 85°C (-40°F to 185°F) |
| Humidity (Operating and Storage) | IEC 60068-2-30/24 h 95 |
| Relative Humidity | 95% relative humidity, 25°C to 40°C (77°F to 104°F) non-condensing |
| EMC | EN 301 489-1 RED EN 301 489-17 EN 55032 Class B (Emission) EN 55035 (Immunity) EN 61000-6-2 Immunity according to Industrial EN 61000-6-3 380-480MHz EN 61000-6-3 800-960MHz EN 60945 Maritime equipment FCC 47 CFR part 15 B, class B (Emission) ICES-003 |
| Magnetic Fields | EN 61 000-4-8, Test level 5 for continuous
field (severe industrial environment) |
| Radio Spectrum | ETSI EN 300 328 ETSI EN 301 893 FCC 47 CFR part 15 RSS-247 |
| Encapsulation | IP67 (IEC 60529) |
| Shock | 25 g (IEC 60068-2-27) |
| Vibration | 2 g (IEC 60068-2-6) |
| Drop | 2 m (6.6 ft.) on concrete floor (IEC 60068-2-31) |
| Safety (Power Supply) | CE/EN/UL/CSA/PSE 60950-1 IEC 62368 |