The Fluke 107 has a slim, palm-sized design that slips easily into a shirt pocket, yet is sturdy enough to endure a one-metre drop. It’s not a true-RMS meter, making it ideal for straightforward applications.
The multimeter is CAT III 600 V safety rated and includes the TL75 Hard Point Test Lead Set and a SmartStrap magnetic lanyard. This flexible strap also doubles as a stand, keeping the display visible at the perfect angle while you work.
Buy a qualifying Fluke Industrial, Fluke Networks or Beha-Amprobe product and earn 1 point for every £1 spent. Redeem points for rewards straight away or save for higher-value gifts.
Offer runs 1 September–31 December 2026. Claims are made through Fluke and offer works in conjuction with our other offers.
Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.
| Precision Specifications | ||||
|---|---|---|---|---|
| AC Voltage (40 Hz to 500 Hz)1 |
Range | Resolution | Accuracy | |
| 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | ||
| DC Voltage | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 | |
| Exchange Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
| Diode Test2 | 2.000 V | 0.001 V | 10 % | |
| Resistance (ohm) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
| Capacitor3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
| Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 | |
| Duty Cycle4 | 1 % to 99 % | 0.10 % | 1 % typical case5 | |
| AC (40 Hz - 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
| DC | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
|
||||
| Features | Overload Protection | Input Impedance (Nominal Value) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Voltage | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at 50 Hz or 60 Hz at DC | − |
| Exchange Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − |
| DC Voltage | 600 V 1 | >10 MΩ <100 pF | >100 dB at 50 Hz or 60 Hz at DC | >60 dB at 50 Hz or 60 Hz |
|
||||
| General Technical Indicators | ||||
| The Highest Voltage Applied to any Terminal and Ground | 600 V | |||
| Display (LCD) | 6000 counts, updated three times per second | |||
| Type of Battery | Two AAA batteries (NEDA 24A, IEC LR03) | |||
| Battery Life | At least 200 hours | |||
| Temperature | ||||
| Operating Temperature | 0 °C to 40 °C | |||
| Storage Temperature | -30 °C to 60 °C | |||
| Relative Humidity | ||||
| Working Humidity | No condensation below
10 °C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C |
|||
| Working Humidity, 40 MΩ Range | ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C | |||
| Altitude | ||||
| Working Elevation | 2000 m | |||
| Storage Altitude | 12,000 m | |||
| Temperature Coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
| Current Input Fuse Protection | 11A, 1000V fast-melting type, must use Fluke-designated parts | |||
| Volume (Height x Width x Length) | 142 mm x 69 mm x 28 mm | |||
| Weight | 200 g | |||
| Protection Level | IEC 60529: IP 40 | |||
| Safety | IEC 61010-1: 600 V CAT III, pollution degree 2 | |||
| Electromagnetic Environment | IEC 61326-1: Portable | |||
| Electromagnetic Compatibility | Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1 | |||
| 1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment. | ||||