This bundle package includes everything an electrician or professional HVAC technician needs for carrying out extensive testing.
The first item includes as part of this package is a Fluke 116 HVAC Multimeter. As its name suggests this device is designed for use by HVAC technicians, but it's also perfectly suitable for use as a regular DMM by electricians as well. It can measure DC millivolts, volts, continuity, current, diode, temperature and capacitance and features a selection of advanced features such as integrated low impedance technology that is designed to filter out errors that might be caused by ghost voltages when testing electrical parameters.
The second item included in this pack is a Fluke 323 True RMS Clamp meter. This device is great for both domestic and all other electricians and can be used to carry out current measurements up to 400A on many different types of cabling installations. The device is also able to carry out AC and DC voltage measurements up to 600V, features easy open clamping system and can also carry out resistance measurements with continuity detection.
This kit also includes test leads, a hanging strap, temperature probe and more.
Fluke 116 HVAC Multimeter Key Features
Ergonomic design makes using the tester in one hand easy
Large integrated screen features an LED backlight for using the tester in darkened conditions
Built in thermometer
Microamp function
Low input impedance function prevents incorrect results because of ghost voltages
Resistance, frequency, continuity and capacitance testing
MIN/MAX/AVG functionality
CAT III 600V safety rating
Fluke 323 True RMS Clamp Meter Key Features
400A AC current measurements
600V AC and DC voltage measurements
True RMS AC/DC voltage and current measurements
Resistance measurements to 40kΩ with continuity detection
Slim, ergonomic design
CAT IV 300V/ CAT III 600V safety rating
Data hold button
Full List of Products Included in Kit
Fluke 116 HVAC Multimeter
TL175 Hard Point Test Lead Set
TPark ToolPak Magnetic Meter Hanging Strap
Flexible Cuff Pipe Clamp Thermocouple
80BK Integrated Temperature Probe
80AK-A Thermocouple Adapter
C115 Deluxe Soft Carrying Case with Shoulder Strap
Fluke 323 True-RMS Clamp Meter
£358.00
£429.60 inc vat
Free Delivery*
In Stock:Available Next Working Day*
Important Notice This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
FREE Oxford Carry Case
PASS Oxford Black Small Test Equipment Carry Case - PASSCASE-SM, typically £14.99
Technical Information
Specification
Fluke 116 Technical Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:
6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.00 V / 0.1 V
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:
600.0 V
Resolution:
0.1 V
Accuracy:
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:
6.000 V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.0 V / 0.1 V
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:
600 Ω
Resolution:
1 Ω
Accuracy:
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:
600.0 Ω / 0.1 Ω
Range/Resolution:
6.000 kΩ / 0.001 kΩ
Range/Resolution:
60.00 kΩ / 0.01 kΩ
Range/Resolution:
600.0 kΩ / 0.1 kΩ
Range/Resolution:
6.000 MΩ / 0.001 MΩ
Accuracy:
0.9 % + 1
Range/Resolution:
40.00 MΩ / 0.01 MΩ
Accuracy:
1.5 % + 2
Diode Test
Range/Resolution:
2.000 V / 0.001 V
Accuracy:
0.9% + 2
Capacitance
Range/Resolution:
1000 nF / 1 nF
Range/Resolution:
10.00 μF / 0.01 μF
Range/Resolution:
100.0 μF / 0.1 μF
Range/Resolution:
9999 μF / 1 μF
Range/Resolution:
100 μF to 1000 μF
Accuracy:
1.9% + 2
Range/Resolution:
> 1000 μF
Accuracy:
5% + 20%
LoZ capacitance
Range:
1 nF to 500 μF
Accuracy:
10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:
-40 °C to 400 °C / 0.1 °C
Accuracy:
1% + 102
Range/Resolution:
-40 °F to 752 °F / 0.2 °F
Accuracy:
1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:
600.0 μA / 0.1 μA
Accuracy:
1.0% + 2
DC μamps
Range/Resolution:
600.0 μA / 0.1 μA
Accuracy:
1.0% + 2
Hz (V or A input)2
Range/Resolution:
99.99 Hz / 0.01 Hz
Range/Resolution:
999.99 Hz / 0.1 Hz
Range/Resolution:
9.999 Hz / 0.001 Hz
Range/Resolution:
50.00 Hz / 0.01 Hz
Accuracy:
0.1% + 2
Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F