All Fluke Calibration Products

Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x TC

SKU
1529-256
Rating:
0%
(0)
Reward Points
:
5933
£7,119.60 £5,933.00
Made to Order Free UK Delivery*
Advice & Support
Price Match Request
Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x TC
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

The Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x Thermocouple Inputs can be used to measure up to four sensors simultaneously.

This instrument is able to accommodate PRTs, thermistor and thermocouple sensor types as it includes inputs for all these probes. The Fluke 1529-256 Chub-E4 Standards Thermometer has two sister products with different probe inputs:

This model is able to accommodate 100Ω, 25Ω and 10Ω PRTs and RTDs as well as thermocouple types B, E, J, K, N, R, S, T and Au-Pt.

When measuring PRTs and RTDs, the Fluke 1529-256 Chub-E4 Standards Thermometer uses ITS-90, IEC-751 (DIN) or Callender-Van Dunsen conversion methods, giving it typical accuracies of ±0.004°C at -100°C and ±0.009°C at 100°C. The Fluke 1529-256 Chub-E4 Standards Thermometer has an accuracy of ±0.0025°C and a resolution of 0.0001° when measuring thermistors and utilises Steinhart-Hart polynomial or a standard YSI-400 curve in order to perform these measurements.

When taking readings of thermocouples the user is able to select between internal and external reference junction compensation.

Measurements can be taken via all four channels simultaneously or sequentially. The Fluke 1529-256 Chub-E4 Standards Thermometer has a standard sample rate for each channel of one reading per second. However, the user is able to set the thermometer to one of fourteen logging intervals ranging from one reading per 0.1 seconds to one per hour. This instrument also includes a high-speed mode which facilitates the thermometer’s ability to conduct ten readings per second (one channel ONLY).

The user is able to view measurements in °C, °F, K, Ω or mV. He/she may also select a temperature resolution between 0.01 and 0.001. In addition to this, the Fluke 1529-256 Chub-E4 Standards Thermometer includes a number of measurement functions, allowing the user to tailor the instrument to the application.

It includes the following statistical function:

  • Average
  • Standard deviation
  • Spread

In addition to this, the Fluke 1529-256 Chub-E4 Standards Thermometer features the following probe options:

  • Probe type
  • Serial number
  • T1-T2 functions using inputs from any two channels

It also features the following utility functions:

  • Date
  • Time
  • Battery power

The user is able to view up to eight data fields from any channel. He/she can select the desired option/s using the simple menu system which is accessible via a single button on the front panel. This simple-to-navigate menu will guide the user through the internal setup and memory options, allowing him/her to access and alter probe coefficients, sample intervals, communication settings and password settings.

In addition to this, the Fluke 1529-256 Chub-E4 Standards Thermometer includes an extensive memory capable of storing up to 10 screen configurations and up to 8000 readings (at user selectable intervals) with date and time stamps. Alternatively, the user can store up to 100 individual measurements with identifying session labels.

Information recorded by the Fluke 1529-256 Chub-E4 Standards Thermometer can be uploaded to a computer using the supplied RS-232 port (OPTIONAL IEEE-488 ports are available).

Once the Fluke 1529-256 Chub-E4 Standards Thermometer has been connected to a computer it can be used with Fluke’s Calibration 9935 LogWare II Software (NOT included) to conduct graphical and statistical data analysis. This software also facilitates the user’s ability to organise files based on session labels, as well as conduct real-time data logging.

Alternatively, this instrument can be used with Fluke’s MET / TEMP II Software (NOT included) in order to conduct automated calibrations, using one probe input as a reference whilst using the others to accommodate the thermometers-under-investigation.

In terms of its physical design, the Fluke 1529-256 Chub-E4 Standards Thermometer includes patented mini DWF connectors ensuring that it is easy to connect thermistors and PRTs with a range of terminations, including bare wire, spade lug and mini banana plug. Thermocouples with standard or miniature terminations are also easy to connect.

This instrument includes a nickel-metal-hydride battery which is able to supply the Fluke 1529-256 Chub-E4 Standards Thermometer with up to eight hours of power between charging. This battery can be charged in three hours and has been optimised for longevity, it is able to last through 500 charge/recharge cycles.

Alternatively, the Fluke 1529-256 Chub-E4 Standards Thermometer can be powered using an AC power supply of 100 to 240V or a DC power supply of 12 to 16V.

The extensive measurement capabilities of the Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x Thermocouple Inputs, as well as its practical design and compact size, makes it suitable for a variety of applications including benchtop thermometry, on-site measurements, lab calibration work and remote data logging. 

 Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x Thermocouple Inputs Key Features

  • Measure up to four sensors simultaneously
  • Can accommodate PRTs, thermistors and thermocouple sensor types
  • Includes two inputs for PRTs/ thermistors
  • Includes two inputs for thermocouples
  • Can accommodate 100Ω, 25Ω and 10Ω PRTs and RTDs
  • Can accommodate the thermocouple types B, E, J, K, N, R, S, T and Au-Pt
  • Uses ITS-90, IEC-751 (DIN) or Callender-Van Dunsen conversion methods to measure PRTs and RTDs
  • Typical accuracy of ±0.004°C at -100°C and ±0.009°C at 100°C when measuring PRTs and RTDs
  • Accuracy of ±0.0025°C and a resolution of 0.0001° when measuring thermistors
  • Uses Steinhart-Hart polynomial or standard YSI-400 curve to measure thermistors
  • Select between internal and external reference junction compensation when measuring thermocouples
  • Measurements can be taken simultaneously or sequentially
  • Standard sample rate for each channel of one reading per second
  • Set the thermometer to one of fourteen logging intervals ranging from one reading per 0.1 seconds to one reading per 60 minutes
  • High-speed mode allows the user to take ten readings per second (via ONE channel ONLY)
  • View measurements in °C, °F, K, Ω or mV
  • Select a temperature resolution of between 0.01 and 0.001
  • Average measurement function
  • Standard deviation measurement function
  • Spread measurement function
  • View the probe type
  • View the serial number
  • Access T1-T2 functions using inputs from any two channels
  • Date function
  • Time function
  • Battery power function
  • View up to eight data fields from any channel
  • Simple menu system accessible via a single button on the front panel
  • Simple-to-navigate menu will guide the user through the internal setup and memory options
  • The user can access and alter probe coefficients, sample intervals, communication settings and password settings using this menu
  • Extensive memory capable of saving up to 8000 readings with date and time stamps
  • Store up to 100 individual measurements with identifying session labels
  • Store up to 10 screen configurations
  • Upload information to a computer via the RS-232 port
  • OPTIONAL IEEE-488 ports are available
  • Use with Fluke’s Calibration 9935 LogWare II Software (NOT included)
  • Compatible with Fluke’s MET / TEMP II Software (NOT included)
  • Includes patented mini DWF connectors ensuring that it is easy to connect thermistors and PRTs with a range of terminations
  • Can accommodate PRTs and thermistors with bare wire, spare lug and mini banana plug terminations
  • Can accommodate thermistors with standard or miniature terminations
  • Includes a nickel-metal-hydride battery that is able to provide the thermometer with up to eight hours of power
  • Battery can be charged in three hours
  • Battery is able to last through up to 500 charge/recharge cycles
  • Can be powered using an AC power supply of 100 to 240V or a DC power supply of 12 to 16V
  • A compact, practical instrument with extensive measurement capabilities
  • Suitable for benchtop thermometry, on-site measurements, lab calibration work and remote data logging

What’s Included?

  • Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x Thermocouple Input

Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x TC Technical Specifications 

Inputs

2 channels PRT/thermistor and 2 channels TC

Models with 4 channels PRT/thermistor, or 4 channels TC are available (please see above)

PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available.)

Specification  PRT/ RTD Thermistor  Thermocouple
Temperature Range  –189 °C to 960 °C  –50 °C to 150 °C  –270 °C to 1800 °C 
Measurement Range  0 to 400 W 0 to 500 KW –10 to 100 mV 
Characterizations  ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen  Steinhart-Hart, YSI-400  NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial 
Temperature Accuracy (meter only)  ± 0.004 °C at –100 °C 
± 0.006 °C at 0 °C 
± 0.009 °C at 100 °C 
± 0.012 °C at 200 °C 
± 0.018 °C at 400 °C 
± 0.024 °C at 600 °C 
± 0.0025 °C at 0 °C 
± 0.0025 °C at 25 °C 
± 0.004 °C at 50 °C 
± 0.010 °C at 75 °C 
± 0.025 °C at 100 °C 
                       Ext. RJC     Int. RJC 
B at 1000 °C  ± 0.6 °C  ± 0.6 °C
E at 600 °C  ± 0.07 °C  ± 0.25 °C
J at 600 °C  ± 0.1 °C  ± 0.35 °C
K at 600 °C  ± 0.15 °C  ± 0.4 °C
N at 600 °C  ± 0.15 °C  ± 0.3 °C
R at 1000 °C  ± 0.4 °C  ± 0.5 °C
S at 1000 °C  ± 0.5 °C  ± 0.6 °C
T at 200 °C  ± 0.1 °C  ± 0.3 °C
Temperature Resolution  0.001 °  0.0001 °  0.01 to 0.001 ° 
Resistance/Voltage Accuracy  W to 20 W:  ± 0.0005W 
20 W to 400 W:  ± 25 ppm of rdg. 
W to 5 KW:  ± 0.5 W 
5 KW to 200 KW:  ± 100 ppm of rdg. 
200 KW to 500 KW ± 300 ppm of rdg. 
–10 to 50 mV:  ± 0.005 mV 
50 to 100 mV:  ± 100 ppm of rdg. 
Internal RJC: ± 0.25 °C) 
Operating Range  16 °C to 30 °C 
Measurement Interval  0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval 
Excitation Current 1 mA, reversing  2 and 10 µA, automatically selected  n/a
Display  33 x 127 mm (1.3 x 5 in) backlit LCD graphical display 
Display Units  °C,  °F, K, W, KW, mV 
Data Logging  Up to 8,000 time- and date-stamped measurements can be logged 
Logging Intervals  .1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes 
Averaging Moving average of most recent 2 to 10 readings, user selectable 
Probe Connection  Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations  Universal receptacle accepts miniature and standard TC connectors 
Communications  RS-232 included, IEEE-488 (GPIB) optional 
AC Power  100–240 V ac, 50-60 Hz, 0.4 A 
DC Power  12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) 
Battery NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles
Size (HxWxD) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) 
Weight  2 kg (4.5 lb) 
Calibration  Accredited resistance and voltage calibrations are provided.

0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 1529-256 Chub-E4 Standards Thermometer–2x Thermistor/PRT & 2x TC
Your Rating
Additional Information
SKU 1529-256
Manufacturer Part Code 1671710

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry