All Fluke Calibration Products

Fluke 1529-R-256 Chub-E4 Standards Thermometer–4x PRT/Thermistor Input

SKU
1529-R-256
Rating:
0%
(0)
Reward Points
:
5933
£7,119.60 £5,933.00
Made to Order Free UK Delivery*
Advice & Support
Price Match Request
Fluke 1529-R-256 Chub-E4 Standards Thermometer – 4x PRT/ Thermistor Input
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

The Fluke 1529-R-256 Chub-E4 Standards Thermometer – 4x PRT/ Thermistor Inputs can be used to measure up to four PRT and/or thermistor sensors simultaneously or sequentially.

This instrument includes four inputs all capable of accommodating PRT and thermistor probes. The Fluke 1529-R-256 Chub-E4 Standards Thermometer has two sister products, each with different probe inputs:

The Fluke 1529-R-256 Chub-E4 Standards Thermometer includes patented mini DWF connectors facilitating the user’s ability to connect PRTs and thermistors with bare wire, spare lug and mini banana plug terminations. This instrument is compatible with 100Ω, 25Ω and 10Ω PRTs and RTDs.

It utilises ITS-90, IEC-751 (DIN) or Callender-Van Dunsen conversion methods to measure PRTs and uses Steinhart-Hart polynomials or a standard YSI-400 curve to measure thermistors. It has an accuracy of ±0.004°C at -100°C and ±0.009°C at 100°C when measuring PRTs. Further to this, it has an accuracy of ±0.0025°C and a resolution of 0.0001° when measuring thermistors.

The user is able to view measurements in °C, °F, K, Ω or mV and can select a temperature resolution of between 0.01 to 0.001°. He/she is able to set the Fluke 1529-R-256 Chub-E4 Standards Thermometer to log measurements as sporadically as one reading per hour or as frequently as one reading per 0.1 seconds. The user can set the Fluke 1529-R-256 Chub-E4 Standards Thermometer to one of fourteen data logging intervals including, and between, these extremes. Ordinarily, this instrument can be set to measure and log readings from all four channels simultaneously or sequentially. However; when it is used in high-speed mode this instrument can log ten measurements per second for ONE channel ONLY.

Measurements acquired using the Fluke 1529-R-256 Chub-E4 Standards Thermometer can be saved to its extensive memory with the capacity to store up to 8000 readings (at user selectable intervals) with date and time stamps. This instrument’s memory is also able to accommodate up to 100 individual readings with identifying session labels. It also features the capacity to save a maximum of ten screen configurations, allowing the user to recall information regarding the set-up of the instrument quickly.

The user is able to access the instrument's memory as well as its internal setup options via the simple-to-use navigation system. This menu guides the operator through probe coefficient, sample interval, communication and password settings allowing him/her to tailor the thermometer to the requirement.

This easy-to-use system is accessible via a single button on the front panel. Via this front panel, the user is able to select to view up to eight data fields from any channel. He/she may also access the Fluke 1529-R-256 Chub-E4 Standards Thermometer’s extensive measurement, set-up and utility functions; these include:

  • Average
  • Standard deviation
  • Spread
  • Probe type
  • Serial number
  • T1-T2 functions using inputs from any two channels
  • Date
  • Time
  • Battery power

Again, allowing the user to tailor the Fluke 1529-R-256 Chub-E4 Standards Thermometer to the application.

Data gathered by the Fluke 1529-R-256 Chub-E4 Standards Thermometer can be uploaded to a PC via the integrated RS-232 port (OPTIONAL IEEE-488 ports are available). Once data has been uploaded to a PC, and/or the Fluke 1529-R-256 Chub-E4 Standards Thermometer has been connected to a PC, the user is able to utilise either of the following optional software programs (NOT included) to conduct an array of tasks:

  • Fluke Calibration 9935 LogWare II Software: organise data using the session labels; perform graphical and/or statistical analysis of uploaded data; conduct real-time data logging.
  • Fluke MET/ TEMP II Software: conduct automated calibrations of thermometers using one of the Fluke 1529-R-256 Chub-E4 Standards Thermometer’s inputs as a reference.

This instrument's extensive measurement, communication, and storage capabilities make the Fluke 1529-R-256 Chub-E4 Standards Thermometer suitable for benchtop thermometry, on-site measurements, lab calibration work and remote data logging. Its compact size also adds to this product’s versatility and practicality as does its ability to be powered using either the included nickel-metal-hydride battery or a mains power supply.

It is possible to operate the Fluke 1529-R-256 Chub-E4 Standards Thermometer using an AC power supply of 100 to 240V or a DC power supply of 12 to 16V. Alternatively, the included nickel-metal-hydride battery can power the instrument for up to eight hours. It is possible to recharge this battery in just three hours. Furthermore, this battery is durable enough to survive up to 500 charge/recharge cycles.

The Fluke 1529-R-256 Chub-E4 Standards Thermometer – 4x PRT/ Thermistor Inputs is a practical, compact instrument with a comprehensive memory and extensive measurement capabilities. It is ideal for a variety of tasks including temperature calibration applications.

Fluke 1529-R-256 Chub-E4 Standards Thermometer – 4x PRT/ Thermistor Inputs Key Features

  • Read up to four PRT or thermistor sensors simultaneously or sequentially
  • Features four inputs all capable of accommodating PRT and thermistor probes
  • Includes patented mini DWF connectors facilitating the user’s ability to connect PRTs and thermistors with bare wire, spare lug and mini banana plug terminations
  • Compatible with 100Ω, 25Ω and 10Ω PRTs and RTDs
  • Utilises ITS-90, IEC-751 (DIN) or Callender-Van Dunsen conversion methods to measure PRTs
  • Uses Steinhart-Hart polynomials or a standard YSI-400 curve to measure thermistors
  • Accuracy of ±0.004°C at -100°C and ±0.009°C at 100°C when measuring PRTs
  • Accuracy of ±0.0025°C when measuring thermistors
  • Resolution of 0.0001° when measuring thermistors
  • View measurements in °C, °F, K, Ω or mV
  • Select a temperature resolution between 0.01 and 0.001°
  • Select from fourteen data logging intervals 
  • Set the thermometer to log data at intervals as sporadically as one measurement per hour or as frequently as one measurement per 0.1 seconds
  • High-speed mode allows the user to take up to ten measurements a second (via ONE channel ONLY)
  • Extensive memory with the capacity to store up to 8000 readings with date and time stamps
  • Store up to 100 individual readings with identifying session labels
  • Save ten screen configurations
  • Simple-to-use navigation system allows the user to access the instrument’s memory and setup options
  • Menu guides the operator through probe coefficient, sample interval, communication and password settings
  • Menu is accessible via a single button on the front panel
  • Select up to eight data fields from any channel to view via the display
  • Average function
  • Standard deviation function
  • Spread function
  • View probe type option
  • View serial number option
  • Select T1-T2 functions using inputs from any two channels
  • Date function
  • Time function
  • Battery power function
  • RS-232 port
  • OPTIONAL IEE-488 ports are available
  • Upload data/ connect the thermometer to a PC using the RS-232 port
  • Can be used with Fluke’s 9935 LogWare II Software (NOT included)
  • Compatible with Fluke’s MET / TEMP II Software
  • Suitable for benchtop thermometry, on-site measurements, lab calibration work and remote data logging
  • Compact size
  • Includes a nickel-metal-hydride battery
  • Battery is able to power the thermometer for up to eight hours
  • Battery takes three hours to recharge
  • Able to withstand up to 500 charge/recharge cycles
  • Can be operated using an AC power supply of 100 to 240V
  • Can be operated using a DC power supply of 12 to 16V
  • Practical, compact instrument with a comprehensive memory and extensive measurement capabilities

What’s Included?

  • Fluke 1529-R-256 Chub-E4 Standards Thermometer – 4x PRT/ Thermistor Inputs

Fluke 1529-R-256 Chub-E4 Standards Thermometer– 4x PRT/ Thermistor Inputs Technical Specifications 

Inputs

4 channels PRT/thermistor

Models with 2 channels PRT/thermistor and 2 channels TC, or 4 channels TC are available (please see above)

PRT/thermistor channels accept 2, 3, or 4 wires; 

Specification  PRT/ RTD Thermistor 
Temperature Range  –189 °C to 960 °C  –50 °C to 150 °C 
Measurement Range  0 to 400 W 0 to 500 KW
Characterizations  ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen  Steinhart-Hart, YSI-400 
Temperature Accuracy (meter only)  ± 0.004 °C at –100 °C 
± 0.006 °C at 0 °C 
± 0.009 °C at 100 °C 
± 0.012 °C at 200 °C 
± 0.018 °C at 400 °C 
± 0.024 °C at 600 °C 
± 0.0025 °C at 0 °C 
± 0.0025 °C at 25 °C 
± 0.004 °C at 50 °C 
± 0.010 °C at 75 °C 
± 0.025 °C at 100 °C 
Temperature Resolution  0.001 °  0.0001 ° 
Resistance/Voltage Accuracy  W to 20 W:  ± 0.0005W 
20 W to 400 W:  ± 25 ppm of rdg. 
W to 5 KW:  ± 0.5 W 
5 KW to 200 KW:  ± 100 ppm of rdg. 
200 KW to 500 KW ± 300 ppm of rdg. 
Operating Range  16 °C to 30 °C 
Measurement Interval  0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval 
Excitation Current 1 mA, reversing  2 and 10 µA, automatically selected 
Display  33 x 127 mm (1.3 x 5 in) backlit LCD graphical display 
Display Units  °C,  °F, K, W, KW, mV 
Data Logging  Up to 8,000 time- and date-stamped measurements can be logged 
Logging Intervals  .1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes 
Averaging Moving average of most recent 2 to 10 readings, user selectable 
Probe Connection  Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations 
Communications  RS-232 included, IEEE-488 (GPIB) optional 
AC Power  100–240 V ac, 50-60 Hz, 0.4 A 
DC Power  12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) 
Battery NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles
Size (HxWxD) 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) 
Weight  2 kg (4.5 lb) 
Calibration  Accredited resistance and voltage calibrations are provided.
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 1529-R-256 Chub-E4 Standards Thermometer–4x PRT/Thermistor Input
Your Rating
Additional Information
SKU 1529-R-256
Manufacturer Part Code 1671722

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.

International Enquiry