All Fluke Products

Fluke 1734 Three-Phase Electrical Energy Logger – Choice of Kit

SKU
Fluke1734
Rating:
0%
(0)
Reward Points
:
3324
£3,324.00 £2,770.00
1 Option in Stock Free UK Delivery*
Choose a Special Offer
  • Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
    Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
    FREE
    £79.00
  • Tolsen Tools Electrician's 14-Piece Insulated Tool Kit SKU: (TS-900013)
    FREE
    £79.00
    Tolsen Tools Electrician's 14-Piece Insulated Tool Kit
Advice & Support
Price Match Request
Free Tool Kit
Fluke 1734 Three-Phase Electrical Energy Logger
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Terms and conditions apply.

The Fluke 1734 Three-Phase Electrical Energy Logger can be used to reduce costs by optimising energy usage. This instrument is able to profile energy usage across a facility and, by performing measurements at multiple points on the power installation, is able to determine sources of energy consumption and/or energy waste, thereby providing the operator with the data required to make informed decisions.

Please note that the Fluke 1734 Three-Phase Electrical Energy Logger is available in four versions; three of these models support Fluke Connect (NOT available on the Fluke 1734/INTL) allowing the user to view data remotely and/or share information with team members thereby enabling real-time, collaborative decisions. Moreover, as the individual and his/her colleagues can view data remotely they are able to remain outside of dangerous areas reducing the need for PPE. Additionally, viewing data remotely reduces the need for frequent site visits and check-ins.  

In addition to this, all of the Fluke 1734 Three-Phase Electrical Energy Loggers are supplied with Fluke’s Energy Analyse Plus Software for comprehensive data analysis and comparison, providing a complete picture of the facility’s energy usage.

These models vary in regards to their included accessories, Wi-Fi capabilities and scopes-for-use. The table below offers a comprehensive overview of the differences and similarities between these models.

Specifications  Model
Model Code  FLUKE-1734/B FLUKE-1734/ EUS FLUKE-1734/ INTL FLUKE-1734/ WINTL
Model Name Fluke 1734/B/INTL Three-Phase Electrical Energy Logger with Wi-Fi and Fluke Connect but WITHOUT Probes Fluke 1734/EUS Three-Phase Electrical Energy Logger with Probes, Fluke Connect and Wi- Fluke 1734/INTL Three-Phase Electrical Energy Logger with Probes but WITHOUT Wi-Fi and Fluke Connect Fluke 1734/WINTL Three-Phase Electrical Energy Logger with Probes, Wi-Fi and Fluke Connect
SKU 4706582 4706594 4706608 4710227
Scope-for-use International - EU, UK, US, AU and BR EU, UK and US International - EU, UK, US, AU and BR International - EU, UK, US, AU and BR
Functions 
Fluke Connect module support (up to 2 modules**
Recording 
Trending 
Communication 
USB (mini B)
WiFi download of instrument data Opt
WiFi download via WiFi access point (requires registration)** Opt Opt Opt Opt
Included Accessories 
WiFi and BLE adapter** Opt Opt
USB flash drive (4GB)
USB Cable
3PHVL-173 Flat Cable
1x red, 1x black 0.1m cable
1x red, 1x black 1.5m lead
Alligator clips 4 4 4 4
C173x Soft Case
Colour Coding set
173x-Hanger kit
MP1-Magnet Probe 4 4 4 4
i173X-flex1500 12” Opt 3 3 3
Line Cord EU, UK, US, AU, BR EU, US, UK EU, UK, US, AU, BR EU, UK, US, AU, BR
Notes * Modules not included
** Not all models are available in all countries. Check with your local Fluke representative.

Energy Measurement

As mentioned above the Fluke 1734 Three-Phase Electrical Energy Logger has been designed to provide the user with a detailed picture of a facility’s energy consumption. As such, it is able to measure and log a variety of power parameters including: 

  • RMS voltage
  • RMS current
  • Voltage
  • Voltage and current THD
  • Active power
  • Reactive power
  • Power factor
  • Active energy
  • Reactive energy

The above parameters are measured and logged simultaneously. The Fluke 1734 Three-Phase Electrical Energy Logger can also be used with three flexible current probes (NOT included with the 1734/B model) to measure all three phases.

Additionally, Fluke Connect compatibility (NOT available on the Fluke 1734/INTL) allows the user to connect other Fluke Connect-enabled testers, such as Fluke’s multimeters, to the Fluke 1734 Three-Phase Electrical Energy Logger allowing it to record an additional two analogue parameters.

Memory and Data Download

As mentioned above, Fluke Connect compatibility allows the user to view data remotely and in real-time.

The Fluke 1734 Three-Phase Electrical Energy Logger will automatically record a number of measurement parameters to ensure that measurement trends are complete. The Fluke 1734 Three-Phase Electrical Energy Logger has the capacity to save up to twenty separate logging sessions and is capable of recording more than a year’s worth of measurements.

Recorded data can be reviewed during the logging sessions prior to download to a PC or USB memory stick. Via the Fluke 1734 Three-Phase Electrical Energy Logger’s bright, colour, touchscreen, graphical display the user can perform in-the-field analysis and data checks Additionally, the inclusion of a USB port enables data to be downloaded directly to a USB memory stick or to a PC via a USB interface. It is also possible to send data to a PC via Wi-Fi transfer (EXCEPT the Fluke 1734/INTL).

Analysis and Reporting 

Once downloaded to a PC, the included Fluke Energy Analyse Plus Software may be used to perform extensive data analysis and comparison, as well as create customised reports. Reports can be sent to customers and colleagues allowing any necessary decisions to be made quickly, thereby optimising energy savings.

Easy-to-use, Practical Design

Fluke Connect compatibility (NOT available on the Fluke 1734/INTL) also allows the user to configure the Fluke 1734 Three-Phase Electrical Energy Logger remotely, improving user safety. Alternatively, the Fluke 1734 Three-Phase Electrical Energy Logger can be configured via the front panel. Both of these methods of configuration mean that the Fluke 1734 Three-Phase Electrical Energy Logger can be left in the field as it does not need to be transported to a workshop for application setup or data download.

Setting up the Fluke 1734 Three-Phase Electrical Energy Logger is made easy as a result of its quick, guided, graphical user interface, ensuring that the relevant data is gathered correctly and reliably.

Also improving measurement reliability and accuracy is the Fluke 1734 Three-Phase Electrical Energy Logger’s intelligent verification feature which checks that test leads and probes are connected correctly. This feature will digitally correct faulty connections without the user having to disconnect or reconnect additional components.

The Fluke 1734 Three-Phase Electrical Energy Logger will also recognise and scale probes automatically. Probes can be connected separately ensuring maximum flexibility. Moreover, the Fluke i173X-flex 1500 Current Probes (NOT included with the Fluke 1734/B model) can be set to 150 A or 1500 A for high accuracy in almost any application. Furthermore, their thin, flexible designs allow the user to access conductors in tight spaces.

This instrument is also supplied with a flat, tangle-free voltage lead for simple and reliable connections to the Fluke 1734 Three-Phase Electrical Energy Logger and the circuit-under-investigation.

Further to this, the Fluke 1734 Three-Phase Electrical Energy Logger features a detachable power supply that is able to derive a power source from the circuit-under-investigation, thereby improving its practicality as the user does not need to rely on battery operation or mains supplies.

Applications

As a result of the Fluke 1734 Three-Phase Electrical Energy Logger’s practical design, eclectic measurement features and logging capabilities, it can be used for a variety of applications.

Load Studies

The Fluke 1734 Three-Phase Electrical Energy Logger can be used to ascertain how much energy individual pieces of equipment are consuming at both minimum and maximum capacity.

Energy Assessments

Energy consumption can be quantified both before and after improvements in order to justify energy saving devices.

Energy Survey  

Take measurements at multiple points within the facility, from the service entrance to individual circuits in order to conduct a complete energy survey.

Logging Related Analogue Measurements

As mentioned above the Fluke 1734 Three-Phase Electrical Energy Logger can be connected to two other Fluke Connect-enabled instruments in order to log up to two additional analogue parameters such as temperature, voltage, current or pressure. Recording these variables provides an overview of the operating conditions, allowing the user to correlate asset performance data with energy consumption in order to make informed cost-saving decisions.

Power and Energy Logging

The Fluke 1734 Three-Phase Electrical Energy Logger is able to measure and characterise the effects of inductive and capacitive loads which may affect peak demand and power factor. Monitoring and analysing these effects enables the user to optimise the peak demand and power factor thereby reducing his/her energy costs.

Simplified Load Studies

In addition to conducting load studies, which involves monitoring voltage and current, the Fluke 1734 Three-Phase Electrical Energy Logger can be used to conduct simplified load studies which only measures the current. This feature is particularly useful when a voltage connection cannot be made. To create a simulated power study, the user is able to enter the nominal expected voltage.

The Fluke 1734 Three-Phase Electrical Energy Logger is an eclectic, efficient and easy-to-use instrument designed to reduce energy costs by identifying ways to optimise energy usage and reduce waste.

Fluke 1734 Three-Phase Electrical Energy Logger Key Features

  • Reduce energy costs and optimise energy usage
  • Profile energy usage across a facility by conducting measurements at multiple points
  • Determine sources of energy consumption and energy waste
  • Provides the user with the data required to make energy-saving decisions
  • Available in four models (see table above)
  • Fluke Connect-enabled
  • View data remotely and/or share measurements with team members via the Fluke Connect App
  • Make real-time, collaborative decisions
  • Viewing data remotely reduces the need for PPE, site visits and check-ins
  • Supplied with Fluke’s Energy Analyse Plus Software for comprehensive data analysis and comparison
  • Measures and logs a variety of parameters simultaneously
  • RMS voltage
  • RMS current
  • Voltage
  • Voltage and current THD
  • Active power
  • Reactive power
  • Power factor
  • Active energy
  • Reactive energy
  • Use the three flexible current probes (NOT included with the Fluke 1734/B) to measure all three phases
  • Connect to other Fluke Connect-enabled instruments to log up to two additional analogue parameters
  • A number of measurement parameters are recorded automatically
  • Save up to twenty logging sessions
  • Log in excess of a year’s worth of measurements
  • Review data during the logging sessions prior to download
  • Download data to a PC or USB stick
  • The USB port facilitates direct download to a USB stick
  • Send data via a USB or Wi-Fi connection (Wi-Fi NOT available on the Fluke 1734/INTL)
  • Create reports using the Fluke Energy Analyse Plus Software
  • Reports can be sent to relevant persons for quick, collaborative decisions
  • Perform in-the-field analysis and data checks via the bright, colour, touchscreen, graphical display
  • Use the Fluke Connect App or front panel to configure the energy logger
  • Configuration via the Fluke Connect App or the front panel means the data logger does not have to be removed from the field
  • A quick, graphical, guided user interface for easy, simple and reliable setup
  • Intelligent verification function for checking connections to test leads and probes
  • The intelligent verification function will digitally correct faulty connections
  • Automatically recognises and scales probes
  • Probes are connected separately for maximum flexibility
  • The Fluke i173X-flex 1500 Current Probes can be set to 150A or 1500A for high-accuracy regardless of the application
  • The Fluke i173X-flex 1500 Current Probes (NOT included with the Fluke 1734/B) are thin enabling access to conductors in tight spaces
  • Flat, tangle-free voltage lead
  • Detachable power supply derives a power source from the circuit-under-investigation
  • Can be used for load studies, simple load studies, energy assessments, energy surveys, logging related analogue measurements, and power and energy logging
  • An eclectic, efficient and easy-to-use instrument designed to help reduce energy costs

What’s Included?

  • Your Choice of Fluke 1734 Three-Phase Electrical Energy Logger (see below)
Model Details   Model Code  FLUKE-1734/B FLUKE-1734/ EUS FLUKE-1734/ INTL FLUKE-1734/ WINTL
Model Name Fluke 1734/B/INTL Three-Phase Electrical Energy Logger with Wi-Fi and Fluke Connect but WITHOUT Probes Fluke 1734/EUS Three-Phase Electrical Energy Logger with Probes, Fluke Connect and Wi- Fluke 1734/INTL Three-Phase Electrical Energy Logger with Probes but WITHOUT Wi-Fi and Fluke Connect Fluke 1734/WINTL Three-Phase Electrical Energy Logger with Probes, Wi-Fi and Fluke Connect
SKU 4706582 4706594 4706608 4710227
Included Products 
Fluke 1734/EUS Three-Phase Electrical Energy Logger  - - -
Fluke 1734/INTL Three-Phase Electrical Energy Logger  -
WiFi and BLE adapter**

-

-
USB flash drive (4GB)
USB Cable
3PHVL-173 Flat Cable
1x red, 1x black 0.1m cable
1x red, 1x black 1.5m lead
Alligator clips 4 4 4 4
C173x Soft Case
Colour Coding set
173x-Hanger kit
MP1-Magnet Probe 4 4 4 4
i173X-flex1500 12” - 3 3 3
Line Cord EU, UK, US, AU, BR EU, US, UK EU, UK, US, AU, BR EU, UK, US, AU, BR

Fluke 1734 Three-Phase Electrical Energy Logger Technical Specifications 

Accuracy
Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale)
Voltage 1000 V 0.1 V ±(0.2% + 0.01%)
Current: Direct input i17xx-flex 1500 12" 150 A 0.1 A ±(1% + 0.02%)
1500 A 1 A ±(1% + 0.02%)
i17xx-flex 3000 24" 300 A 1 A ±(1% + 0.03%)
3000 A 10 A ±(1% + 0.03%)
i17xx-flex 6000 36" 600 A 1 A ±(1.5% + 0.03%)
6000 A 10 A ±(1.5% + 0.03%)
i40s-EL clamp 4 A 1 mA ±(0.7% + 0.02%)
40 A 10 mA ±(0.7% + 0.02%)
Frequency 42.5 Hz to 69 Hz 0.01 Hz ±(0.1%)
Auxillary input ±10 V dc 0.1 mV ±(0.2% + 0.02%)
Voltage min/max 1000 V 0.1 V ±(1% + 0.1%)
Current min/max Defined by accessory Defined by accessory ±(5% + 0.2%)
THD on voltage 1000% 0.1% ±0.5
THD on current 1000% 0.1% ±0.5
Intrinsic Uncertainty ±(% of reading +% of range)¹
Parameter Influence quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
150 A / 1500 A 300 A / 3000 A 600 A / 6000 A 4 A / 40 A
Active Power P PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Active Energy Ea PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent power S 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent Energy Eap 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Reactive power Q 0 ≤ PF ≤ 1 2.5% of measured apparent power
Reactive Energy Er 0 ≤ PF ≤ 1 2.5% of measured apparent power
Power Factor PF - ±0.025
Displacement Power Factor - ±0.025
DBF/cosϕ - ±0.025
Additional uncertainty in% of range¹ VP-N>250 V 0.015% 0.0225% 0.0225% 0.015%
¹Range = 1000 V x Irange
Reference conditions:
  • Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65%
  • Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%.
  • Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10% of Irange
  • Primary conductor of clamps or Rogowski coil in center position
  • Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

 

Electrical Specifications
Power Supply
Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency ≥ 68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input
Mains power frequency 50/60 Hz ±15%
Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time < 6 hours
Data Acquisition
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency 50/60 Hz (42.5 to 69 Hz)
Circuit types 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹
¹The number of possible logging sessions and logging period depends on user requirements.
Basic Interval
Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Demand Interval (Energy Meter Mode)
Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Standards Compliance
Power IEEE 1459
Interfaces
USB-A File transfer via USB flash drive, firmware updates
Max. current: 120 mA
WiFi File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)
USB-mini Data download device to PC
Voltage Inputs
Number of inputs 4 (3 phases and neutral)
Maximum input voltage 1000 Vrms, CF 1.7
Input impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Measurement category 1000 V CAT III/600 V CAT IV
Current Inputs
Number of inputs 3, mode selected automatically for attached sensor
Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12"
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24"
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36"
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Auxiliary Inputs
Number of inputs 2
Input range 0 to ±10 V dc, 1reading/s
Scale factor (available 2014) Format: mx + b (gain and offset) user configurable
Displayed units (available 2014) User configurable (7 characters, for example, °C, psi, or m/s)
Wireless Connection
Number of inputs 2
Supported modules Fluke Connect® 3000 series
Acquisition 1 reading/s
Environmental Specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH
Operating altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000m
Enclosure IP50 in accordance with EN60529
Vibration MIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1
IEC Mains Input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
Electromagnetic compatibility EN 61326-1: Industrial CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature coefficient 0.1 x accuracy specification/°C
General Specifications
Color LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Warranty Instrument and power supply: Two-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Dimensions Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in)
Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in)
Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in)
Weight Instrument: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
Tamper protection Kensington lock slot
i17xx-flex 1500 12" Flexible Current Probe Specifications
Measuring range 1 to 150 A ac/10 to 1500 A ac
Nondestructive current 100 kA (50/60 Hz)
Intrinsic error at reference condition* ±0.7% of reading
Accuracy 173x + iFlex ±(1% of reading + 0.02% of range)
Temperature coefficient over operating temperature range 0.05% of reading/°C 0.09% of reading/°F
Working voltage 1000 V CAT III, 600 V CAT IV
Probe cable length 305 mm (12 in)
Probe cable diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Output cable length 2 m (6.6 ft)
Weight 115 g
Probe cable material TPR
Coupling material POM + ABS/PC
Output cable TPR/PVC
Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating 15% to 85% non-condensing
IP rating IEC 60529:IP50
Warranty One-year
* Reference condition:
  • Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65%
  • Primary conductor in center position
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 1734 Three-Phase Electrical Energy Logger – Choice of Kit
Your Rating
Additional Information
SKU Fluke1734
Manufacturer Part Code 4706582
International Enquiry