The Fluke 17B+ Digital Multimeter builds on the strengths of the 15B+ by adding extra functionality, making it a worthy companion for electricians and serious DIYers. It has a one-handed operation, even with gloves, and a large backlit display provides readings in all lighting conditions.
The 17B+ measures AC/DC voltage up to 1000 V and current up to 10 A, and includes resistance, continuity, capacitance, and diode testing functions. Where the 17B+ sets itself apart is in its ability to measure frequency and temperature, expanding its usefulness to applications such as refrigeration, HVAC, and electronic system checks.
Supplied with a Type K thermocouple, it enables temperature readings and electrical diagnostics. The meter also has relative measurement capability, allowing you to zero out baseline readings. Safety is built in, with a CAT III 600 V rating and overload protection.
below does not match fluke site - have mirrored fluke for now * Main Unit * Test Leads With Two Caps * Cd Manual * Statement Of Calibration * Insert,Molded * Bag,Polyethylene * Safety Sheet
Buy a Fluke and Get a Free Fluke! Spend over £150 on a qualifying Fluke product and choose an additional Fluke product for Free. Offer is claimed directly from Fluke. Valid 15th Sept 25 - 31 Dec 2025. For more details visit buy a fluke offer.
Worth £29.99. Automatically adds to your basket when the total exceeds £500+ (ex VAT). Limited Stock. More details here.
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| AC Volts (40 Hz to 500Hz)1 |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0% + 3 |
| DC Volts | 4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5% + 3 |
| AC Millivolts | 400.0 mV | 0.1 mV | 3.0% + 3 |
| DC Millivolts | 400.0 mV | 0.1 mV | 1.0% + 10 |
| Diode Test2 | 2.000 V | 0.001 V | 10% |
| Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5% + 3 0.5% + 2 0.5% + 2 0.5% + 2 0.5% + 2 1.5% + 3 |
| Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 |
| Frequency1 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1% + 3 |
| Duty Cycle1 | 1% to 99% | 0.1% | 1% typical 4 |
| AC Current μA (40 Hz to 400 Hz) |
400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 |
| AC Current mA (40 Hz to 400 Hz) |
40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 |
| AC Current A (40 Hz to 400 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 |
| DC Current μA | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5% + 3 |
| DC Current mA | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5% + 3 |
| DC Current A | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5% + 3 |
| Temperature | 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C |
0.1C | 2% ±1 °C ±2 °C 9% ±2 °C |
| Backlight | Yes | ||
| 1All ac, Hz, and duty cycle are specified from 1% to 100% of the range. Inputs below 1% of the range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3. Specifications do not include errors due to test lead capacitance and capacitance floor (which may be up to 1.5 nF in the 40 nF range). 4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%. |
|||
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz |
- |
| AC Millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
| DC Volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
| DC Millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
| 1 106 V Hz Max | ||||
| General Specifications | |
| Maximum Voltage between any Terminal and Earth Ground | 1000 V |
| Display (LCD) | 4000 counts, updates 3/sec |
| Battery Type | 2 AA, NEDA 15A, IEC LR6 |
| Battery Life | 500 hours minimum |
| Operating Temperature | 0 °C to 40 °C |
| Storage Temperature | -30 °C to 60 °C |
| Operating Humidity (RH) | Non-condensing (<10°C) ≤90% RH at 10 °C to 30 °C ≤75% RH at 30 °C to 40 °C |
| 40 MΩ range ≤80% RH at 10 °C to 30 °C ≤70% RH at 30 °C to 40 °C |
|
| Operating Altitude | 2000 m |
| Storage Altitude | 12,000 m |
| Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
| Fuse Protection for Current Inputs | 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only. |
| Size (H x W x L) | 183 x 91 x 49.5 mm |
| Weight | 455 g |
| IP Rating | IP 40 |
| Safety | IEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2 |
| Electromagnetic Compatibility | IEC 61326-1: Portable EMC Environment |
| Class A equipment (industrial broadcasting and communication equipment)1 1 This product meets requirements for industrial (Class A) electromagnetic wave equipment, and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. |
|