The Fluke 810 Vibration Tester is a diagnostic vibration analysis tool designed to help maintenance teams identify and prioritise mechanical faults without requiring prior measurement history. Its built-in diagnostic engine analyses machine condition and reports specific faults and their severity during the first measurement.
The tester identifies common mechanical problems, including bearing faults, misalignment, unbalance, and looseness, while overall vibration readings and spectral diagrams provide a clear indication of machine health. A four-level fault severity scale and repair recommendations help maintenance teams focus on the most critical issues first.
The Fluke 810 supports a wide range of rotating equipment, including belt drives, gearboxes, and bevel gears. A tri-axial accelerometer reduces measurement time compared to single-axis sensors, while on-board help guides users through the testing process. Detailed diagnostic reports, expandable memory, and a self-test function further support efficient maintenance and troubleshooting programmes.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
Buy a qualifying Fluke Industrial, Fluke Networks or Beha-Amprobe product and earn 1 point for every £1 spent. Redeem points for rewards straight away or save for higher-value gifts.
Offer runs 1 September–31 December 2026. Claims are made through Fluke and offer works in conjuction with our other offers.
| Diagnostic | |
|---|---|
| Standard Faults | Standard faults: Unbalance, looseness, misalignment and bearing failures |
| Analysis for | Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed-coupled machines, spindles |
| Machine Rotational Speed Range | 200 rpm to 12000 rpm |
| Diagnosis Details | Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra |
| Electrical | |
| Ranging | Automatic |
| A/D Converter | 4 channel, 24 bit |
| Usable Frequency Bandwidth | 5 Hz to 20 kHz |
| Digital Signal Processing Functions | Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging |
| Sampling Rate | 128 dB |
| Signal to Noise Ratio | 100 dB |
| FFT Resolution | 800 lines |
| Spectral Windows | Hanning |
| Frequency Units | Hz, orders, cpm |
| Amplitude Units | in/sec, mm/sec, VdB (US), VdB* (Europe) |
| Non-Volatile Memory | SD micro memory card, 2 GB internal + user accessible slot for an additional 2 GB of storage |
| General | |
| Dimensions (HxDxW) | 18.56 cm x 7.00 cm x 26.72 cm (7.30 in x 2.76 in x 10.52 in) |
| Weight (with Battery) | 1.9 kg (4.2 lb) |
| Display | ¼ VGA, 320 x 240 Colour (5.7 inch diagonal) TFT LCD with LED backlight |
| Input/Output Connections | Triaxial sensor connection: 4-pin M12 connector Single-axis sensor connection: BNC connector PC connection: Mini DIN 6-pin connector / Mini ‘B’ USB (2.0) connector |
| Battery | Battery type Lithium-ion: 14.8 V, 2.55 Ah Battery charging time: Three hours Battery discharge time: Eight hours (under normal conditions) |
| AC Adapter | Input voltage: 100 V ac to 240 V ac Input frequency: 50/60 Hz |
| Operating System | WinCE 6.0 Core |
| Language Support | English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish |
| Fluke Warranty | Three-years |
| Environmental | |
| Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F) |
| Operating Humidity | 10 % to 95 % RH (non-condensing) |
| Agency Approvals | CHINA RoHS, CSA, CE, C TICK, WEEE |
| Electromagnetic Compatibility | EN 61326-1:2006, EN 61010:1:2001 2nd ed. |
| Sensor | |
| Sensor Type | Accelerometer |
| Sensitivity | 100 mV/g (± 5 %, 25 °C) |
| Acceleration Range 80 g Peak | 80 g peak |
| Amplitude Nonlinearity | 1 % |
| Frequency Response | Z: 2 to 7,000 Hz ± 3dB X, Y: 2 to 5,000 Hz ± 3 dB |
| Power Requirement (IEPE) | 18 V dc to 30 V dc, 2 mA to 10 mA |
| Bias Output Voltage | 12 V DC |
| Grounding | Case grounded |
| Sensing Element Design | PZT ceramic / shear |
| Case Material | 316L stainless steel |
| Mounting | 10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength) |
| Output Connector | 4-Pin, M12 |
| Mating Connector | M12 - F4D |
| Non-Volatile Memory | TEDS 1451.4 compatible |
| Vibration Limit | 500 g peak |
| Shock Limit | 5000 g peak |
| Electromagnetic Sensitivity, Equivalent g | 100 μg/gauss |
| Sealing | Hermetic |
| Temperature Range | -50 °C to 120 °C (-58 °F to 248 °F) ± 7 % |
| Fluke Warranty | One-year |