Ideal for any electrician or other professional requiring general electrical measurements, this bundle package comes with the following Fluke equipment:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke a3000 FC Wireless AC Current Clamp Module
- TL175 Test Leads
- AC175 Alligator Clips
The equipment in this kit allows users to carry out measurements of current completely wirelessly. Just connect the included module to a measurement point and it'll transmit data completely wirelessly to the included multimeter. It's also possible to use a smartphone (with Fluke Connect app) or a PC (using optional pc3000 adapter) to view back the transmitted data.
Fluke 3000 FC Wireless Digital Multimeter
Ideal for basic electrical measurements, this unique digital multimeter can also transmit and receive data using Fluke Connect!
- AC/DC voltage measurements
- AC/DC current measurements
- Continuity, resistance, diode, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000V and CAT IV 600V rated
- IP54 ingress protection
Fluke a3000 FC Wireless AC Current Clamp Module
Connect this module to a measurement point and take readings safely from a distance with the multimeter!
- True RMS AC clamp meter
- Measure up to 400A AC
- Use as a standalone meter or as part of the system
- Logging function stores up to 65000 readings
- Inrush function
Fluke 3000 FC Wireless Multimeter Specifications
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 to 28°C with relative humidity of 0 to 90%. Accuracy specifications take the form of ± [[ % of reading ] + [ Number of least significant digits ]].
AC Voltage | ||||
Range | Resolution | Accuracy | ||
45Hz to 500Hz | 500Hz to 1KHz | |||
600.0mV | 0.1mV | 1.0% + 3 | 2.0% + 3 | |
6.000V | 0.001V | |||
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | |||
Note |
All AC voltage ranges are specified from 1% of range to 100% of range. |
|||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0mV | 0.1mV | 0.09% + 2 | |
V | 6.000V | 0.001V | 0.09% + 2 | |
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | 0.15% + 2 | ||
Ω | 600.0Ω | 0.1Ω | 0.5% + 1 | |
6.000kΩ | 0.001kΩ | |||
60.00kΩ | 0.01kΩ | |||
60.00kΩ | 0.1kΩ | |||
600.0kΩ | 0.001MΩ | |||
50.00MΩ | 0.01MΩ | 1.5% + 3 | ||
Diode Test | 2.000V | 0.001V | 1% + 2 | |
μF | 1000nF | 1nF | 10% typical | |
10.00μF | 0.01μF | |||
100.0μF | 0.1μF | |||
9999μF | 1μF | |||
Note | In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2 |
|||
AC and DC Current | ||||
Function | Range | Resolution | Accuracy | |
mA AC (45Hz to 1KHz) | 60.00mA | 0.01mA | 1.5% + 3 | |
400.0mA | ||||
mA DC | 60.00mA | 0.01mA | 0.5% + 3 | |
400.0mA | 0.1mA | |||
Note | All AC current ranges are specified from 5% of range to 100% of range Input burden voltage (typical): 400mA input 2mV/mA 400.0mA accuracy specified up to 600mA overload |
|||
Frequency | ||||
Range | Resolution | Accuracy | ||
99.99Hz | 0.01Hz | 0.1% + 1 | ||
999.9Hz | 0.1Hz | |||
9.999kHz | 0.001Hz | |||
99.99kHz | 0.01kHz | |||
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio (1kΩ Unbalance) | Normal Mode Rejection |
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
1100V rms | >10MΩ < 100pF | > 60 dB, dc to 60 Hz | ||
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | Full Scale Voltage | Typical Short Circuit Current | ||
1100V rms | <2.7V DC | To 6MΩ: <0.7VDC 50MΩ: <0.9V DC |
<350mA | |
1100V rms | <2.7V DC | 2.000V DC | <1.1mA | |
Function | Overload Protection |
Overload | ||
mA | Fused, 44/100A, 1000V FAST Fuse |
600mA overload for 2 minutes maximum, 10 minutes rest minimum |
||
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC Functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. | |||
AC Functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration. | |||
General Specifications | ||||
Maximum Voltage Between Any Terminal and Earth Ground | 1000V DC or AC RMS | |||
Ω Fuse Protection From A Inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
|||
Battery Type | 3 x AA alkaline batteries, NEDA 15A IEC LR6 | |||
Battery Life | 250 hours maximum | |||
RF Communications | 2.4GHZ ISM Band | |||
RF Communication Range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
|||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
|||
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
Relative Humidity | 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) | |||
Altitude | Operating: 2,000 m Storage: 12,000 m |
|||
Electromagnetic Compatability EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
|||
Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
|||
Certifications | CSA, FCC, CE | |||
Ingress Protection (IP) Rating | IP54 | |||
Pollution Degree | 2 | |||
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) | |||
Weight | 340g (12oz) |
SKU | FLK-A3000 FC KIT |
---|---|
Manufacturer Part Code | 4465618 |
Model Ref | FLK-A3000 FC CLAMP KIT |
Country of Origin | United States |