This comprehensive Fluke bundle package contains everything you'll need for measuring common electrical parameters and even includes the ability to measure temperature completely wirelessly using the supplied temperature module!
The kit comes with the following items:
- Fluke 3000 FC Series Wireless Multimeter
- Fluke t3000 K-Type Thermocouple Thermometer
- TL175 Test Leads
- AC175 Alligator Clips
- 80PK-1 K-Type Bead Thermocouple
- Magnetic Hanging Strap
The included thermometer is capable of being used by itself as a temperature measurement tool or can wirelessly transmit data to the included multimeter (and other compatible Fluke Connect tools).
Fluke Connect - Wirelessly Enhancing Testing
With this technology, many of Fluke's testers can now transmit data to each other! It also works with smartphones (using the Fluke Connect app) and can be used to transmit data wirelessly to PC (using optional PC adapter - sold separately).
The following video outlines how Fluke connect works:
With Fluke Connect, its possible to connect the included temperature module somewhere and view the results back up to 20m away on the included multimeter! Alternatively, why not connect up your smartphone for even more options such as video sharing or measurement saving?
Fluke 3000 FC Wireless Digital Multimeter
Ideal for measurements and general electrical troubleshooting, Fluke's 3000 is versatile, easy-to-use and extremely accurate thanks to true RMS technology.
- AC/DC voltage measurements
- AC/DC current measurements
- Continuity, resistance, diode, capacitance and frequency testing
- MIN/MAX recording
- CAT III 1000V and CAT IV 600V
- IP54 ingress protection
Fluke t3000 FC Wireless K-Type Temperature Module
Measure temperature with direct contact and transmit your findings wirelessly!
- -200 to 1372°C measurement range
- High accuracy
- Stores up to 65000 measurements
- Can be used by itself or can transmit data to other connected Fluke tools
Fluke 3000 FC Wireless Multimeter Specifications
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 to 28°C with relative humidity of 0 to 90%. Accuracy specifications take the form of ± [[ % of reading ] + [ Number of least significant digits ]].
AC Voltage | ||||
Range | Resolution | Accuracy | ||
45Hz to 500Hz | 500Hz to 1KHz | |||
600.0mV | 0.1mV | 1.0% + 3 | 2.0% + 3 | |
6.000V | 0.001V | |||
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | |||
Note |
All AC voltage ranges are specified from 1% of range to 100% of range. |
|||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0mV | 0.1mV | 0.09% + 2 | |
V | 6.000V | 0.001V | 0.09% + 2 | |
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | 0.15% + 2 | ||
Ω | 600.0Ω | 0.1Ω | 0.5% + 1 | |
6.000kΩ | 0.001kΩ | |||
60.00kΩ | 0.01kΩ | |||
60.00kΩ | 0.1kΩ | |||
600.0kΩ | 0.001MΩ | |||
50.00MΩ | 0.01MΩ | 1.5% + 3 | ||
Diode Test | 2.000V | 0.001V | 1% + 2 | |
μF | 1000nF | 1nF | 10% typical | |
10.00μF | 0.01μF | |||
100.0μF | 0.1μF | |||
9999μF | 1μF | |||
Note | In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2 |
|||
AC and DC Current | ||||
Function | Range | Resolution | Accuracy | |
mA AC (45Hz to 1KHz) | 60.00mA | 0.01mA | 1.5% + 3 | |
400.0mA | ||||
mA DC | 60.00mA | 0.01mA | 0.5% + 3 | |
400.0mA | 0.1mA | |||
Note | All AC current ranges are specified from 5% of range to 100% of range Input burden voltage (typical): 400mA input 2mV/mA 400.0mA accuracy specified up to 600mA overload |
|||
Frequency | ||||
Range | Resolution | Accuracy | ||
99.99Hz | 0.01Hz | 0.1% + 1 | ||
999.9Hz | 0.1Hz | |||
9.999kHz | 0.001Hz | |||
99.99kHz | 0.01kHz | |||
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio (1kΩ Unbalance) | Normal Mode Rejection |
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
1100V rms | >10MΩ < 100pF | > 60 dB, dc to 60 Hz | ||
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | Full Scale Voltage | Typical Short Circuit Current | ||
1100V rms | <2.7V DC | To 6MΩ: <0.7VDC 50MΩ: <0.9V DC |
<350mA | |
1100V rms | <2.7V DC | 2.000V DC | <1.1mA | |
Function | Overload Protection |
Overload | ||
mA | Fused, 44/100A, 1000V FAST Fuse |
600mA overload for 2 minutes maximum, 10 minutes rest minimum |
||
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC Functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. | |||
AC Functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration. | |||
General Specifications | ||||
Maximum Voltage Between Any Terminal and Earth Ground | 1000V DC or AC RMS | |||
Ω Fuse Protection From A Inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
|||
Battery Type | 3 x AA alkaline batteries, NEDA 15A IEC LR6 | |||
Battery Life | 250 hours maximum | |||
RF Communications | 2.4GHZ ISM Band | |||
RF Communication Range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
|||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
|||
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
Relative Humidity | 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) | |||
Altitude | Operating: 2,000 m Storage: 12,000 m |
|||
Electromagnetic Compatability EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
|||
Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
|||
Certifications | CSA, FCC, CE | |||
Ingress Protection (IP) Rating | IP54 | |||
Pollution Degree | 2 | |||
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) | |||
Weight | 340g (12oz) |
Fluke t3000 Technical Specifications
Range (K-Type) | -200 °C to 1372 °C |
Resolution | 0.1 °C |
Accuracy | ± [0.5% + 0.5°C] counts |
Input Terminals | K-Type Mini |
LCD w/ Backlight | 3 1/2 digits |
Log Rate/Interval | 1 sec minimum/adjustable by PC |
Battery Type | 2 AA, NEDA 15A, IEC LR6 |
Battery Life | 400 hours |
Memory | Record up to 65000 readings |
RF Communications | 2.4GHZ ISM band |
RF Communication Range | Open Air, Ubobstructed: Up to 20m Obstructed, Sheetrock Wall: Up to 6.5m Obstructed, Concrete Wall or Steel Electrical Enclosure: Up to 3.5m |
Operating Temperature | -10 °C to +50 °C |
Storage Temperature | -40 °C to +60 °C |
Temperature Coefficient | 0.01 % of reading +0.03 °C per °C |
Temperature Scale | ITS-90 |
Operating Humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
Altitude | Operating: 2000m Storage: 12000m |
EMC | EN 61326-1: 2006 |
Safety Compliance | IEC 61010-1, CAT I, 3rd edition, Pollution degree 2 |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) Rating | IP42 |
Pollution Degree | 2 |
Size (H x W x D) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22kg (8oz) |
SKU | FLK-T3000 FC KIT |
---|---|
Manufacturer Part Code | 4465652 |
Model Ref | FLK-T3000 FC KIT TEMP |