Part of Fluke's Connect range, the 3000 FC allows the user to gain wireless readings from compatible Fluke Connect modules (sold separately), making testing easier, safer and even allowing direct measurements of electrical properties in usually inaccessible areas such as electrical panels.
CAT IV 600V and CAT III 1000V rated for use in even the toughest of environments, this multimeter delivers reliable, accurate results with high basic accuracy of just 0.09%. It's true RMS as well and will still deliver accurate measurement even when used with non-sinusoidal waveforms.
The Fluke 3000 FC allows the user to carry out measurements of AC and DC voltage to 1000V, resolution to 50MΩ, capacitance to 9999μF, AC/DC current to 400mA and frequency, diode and continuity testing. The range and functions of this instrument can be further expanded by connecting to Fluke's Connect remote modules (range depends on connected module type).
Fluke Connect - Wireless, Safe Measurements
Don't risk your safety when testing; with Fluke Connect, users can carry out wireless measurements up to 20m away from connected remote modules! All you'll need to use Fluke Connect is a Fluke remote module, a 3000 FC wireless multimeter, Fluke's PC adaptor or an Android/Apple mobile device that's running Fluke's new Connect app.
The following video outlines the functionality of Fluke Connect:
With the ability to do everything from storing images and creating a comprehensive wireless monitoring network, Fluke Connect opens up testing like never before.
Fluke 3000 FC Series Wireless Digital Multimeter Key Features
- Connect wirelessly to smartphones running Fluke Connect app
- Wireless interfacing with Fluke remote modules (sold separately)
- Compatible modules: iFlex True RMS AC Current Clamp Module, True-RMS AC Current Clamp Module, AC Voltage Module, K-Type Temperature Module, AC/DC Current Clamp Module, DC Voltage Module, PC Adapter
- AC/DC voltage measurements to 1000V
- Resistance measurements to 50MΩ
- Diode and capacitance testing
- DC/AC current measurements to 400mA
- Frequency measurements to 99.99kHz
- 250 hour average battery life
What's Included?
- Fluke 3000 FC Series Wireless Digital Multimeter
- TL175 Test Leads
- AC175 Alligator Clips
Fluke 3000 FC Wireless Multimeter Specifications
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 to 28°C with relative humidity of 0 to 90%. Accuracy specifications take the form of ± [[ % of reading ] + [ Number of least significant digits ]].
AC Voltage | ||||
Range | Resolution | Accuracy | ||
45Hz to 500Hz | 500Hz to 1KHz | |||
600.0mV | 0.1mV | 1.0% + 3 | 2.0% + 3 | |
6.000V | 0.001V | |||
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | |||
Note |
All AC voltage ranges are specified from 1% of range to 100% of range. |
|||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0mV | 0.1mV | 0.09% + 2 | |
V | 6.000V | 0.001V | 0.09% + 2 | |
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V | 0.15% + 2 | ||
Ω | 600.0Ω | 0.1Ω | 0.5% + 1 | |
6.000kΩ | 0.001kΩ | |||
60.00kΩ | 0.01kΩ | |||
60.00kΩ | 0.1kΩ | |||
600.0kΩ | 0.001MΩ | |||
50.00MΩ | 0.01MΩ | 1.5% + 3 | ||
Diode Test | 2.000V | 0.001V | 1% + 2 | |
μF | 1000nF | 1nF | 10% typical | |
10.00μF | 0.01μF | |||
100.0μF | 0.1μF | |||
9999μF | 1μF | |||
Note | In the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2 |
|||
AC and DC Current | ||||
Function | Range | Resolution | Accuracy | |
mA AC (45Hz to 1KHz) | 60.00mA | 0.01mA | 1.5% + 3 | |
400.0mA | ||||
mA DC | 60.00mA | 0.01mA | 0.5% + 3 | |
400.0mA | 0.1mA | |||
Note | All AC current ranges are specified from 5% of range to 100% of range Input burden voltage (typical): 400mA input 2mV/mA 400.0mA accuracy specified up to 600mA overload |
|||
Frequency | ||||
Range | Resolution | Accuracy | ||
99.99Hz | 0.01Hz | 0.1% + 1 | ||
999.9Hz | 0.1Hz | |||
9.999kHz | 0.001Hz | |||
99.99kHz | 0.01kHz | |||
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio (1kΩ Unbalance) | Normal Mode Rejection |
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
1100V rms | >10MΩ < 100pF | > 60 dB, dc to 60 Hz | ||
1100V rms | >10MΩ < 100pF | > 120 dB at dc, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | Full Scale Voltage | Typical Short Circuit Current | ||
1100V rms | <2.7V DC | To 6MΩ: <0.7VDC 50MΩ: <0.9V DC |
<350mA | |
1100V rms | <2.7V DC | 2.000V DC | <1.1mA | |
Function | Overload Protection |
Overload | ||
mA | Fused, 44/100A, 1000V FAST Fuse |
600mA overload for 2 minutes maximum, 10 minutes rest minimum |
||
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC Functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. | |||
AC Functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration. | |||
General Specifications | ||||
Maximum Voltage Between Any Terminal and Earth Ground | 1000V DC or AC RMS | |||
Ω Fuse Protection From A Inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
|||
Battery Type | 3 x AA alkaline batteries, NEDA 15A IEC LR6 | |||
Battery Life | 250 hours maximum | |||
RF Communications | 2.4GHZ ISM Band | |||
RF Communication Range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
|||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
|||
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
Relative Humidity | 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) | |||
Altitude | Operating: 2,000 m Storage: 12,000 m |
|||
Electromagnetic Compatability EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
|||
Safety Compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
|||
Certifications | CSA, FCC, CE | |||
Ingress Protection (IP) Rating | IP54 | |||
Pollution Degree | 2 | |||
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) | |||
Weight | 340g (12oz) |
SKU | FLK-3000 FC |
---|---|
Manufacturer Part Code | 4401595 |
Country of Origin | United States |