All Kane Products

Kane AQA Indoor Air Quality Analyser – Choice of Gas Sensors

SKU
KANE-AQAX
Rating:
0%
(0)
Reward Points
:
738
£738.00 £615.00
Free UK Delivery*
Advice & Support
Price Match Request
Kane AQA Indoor Air Quality Analyser – Choice of Gas Sensors

Available with your choice of gas sensors (max four), the Kane AQA Indoor Air Quality Analyser is a configurable gas analyser that can be tailored to test an array of domestic and commercial boilers, heat pumps, flueless gas appliances, and space/water heaters. The Kane AQA Indoor Air Quality Analyser is perfect for testing room and workplace indoor air quality, airflow, temperature, and relative humidity.

Gas Options

There are four versions of the Kane AQA Indoor Air Quality Analyser available: one gas, two gas, three gas, and four gas. These can be fitted with the gas sensor/s of your choice.

Please contact us with your selection after your purchase.

Gas Sensor  Range
Carbon Dioxide (CO2)  0-20%
Carbon Dioxide (CO2)  0-9999ppm
Carbon Monoxide (CO) 0-2000ppm
10000ppm H2 Compensated   
Nitric Oxide (NO) 0-600ppm
Oxygen (O2) 0-21%

Tests & Capabilities

The Kane AQA Indoor Air Quality Analyser’s exact measurement and testing capabilities depend on the number and type of sensors fitted. Depending on the sensor configuration, the Kane AQA Indoor Air Quality Analyser can test type C sealed appliances, type B boiler open flue, and type A cookers and space/water heaters; it can also support the following:

  • Measure up to four gases simultaneously
  • Differential pressure: -80 to +80mBar
  • CO and CO2 safety tests
  • Gas appliance integrity tests: tightness, let by, and appliance sweep test
  • Flueless gas appliance and space/water heater tests
  • Room migration timed test for CO and CO2 with ambient CO2
  • Appliance timed sweep test for CO and CO2 with ambient CO2 sensor
  • Heat pump differential and return temperature (with optional Kane WPCP2 Clamp Probes)
  • Differential temperature: -20°C to +1350°C (with additional probes)
  • Airflow: 1.1 to 20m/s (with KANE-DTHA2)
  • Temperature: -20°C to +50°C (with KANE-DTHA2)
  • Relative Humidity: 0.1-99% (with KANE-DTHA2)
  • Room CO: 0-999ppm (with optional Kane 79 CO Monitor – conduct fast track UK CMDDA1 CO investigations by measuring four rooms simultaneously with four Kane 79 CO Monitors)

Depending on the Kane AQA Indoor Air Quality Analyser’s sensor configuration, it meets the following standards:

  • EN50543 for ambient CO2 and CO
  • EN50379 for O2, CO, and NO
  • CIS23 and BS8494 for testing commercial catering appliances for UK CP42 certificates

Other Functions

Measurements may be frozen on the Kane AQA Indoor Air Quality Analyser’s screen using the Data Hold function. Readings are logged to the Kane AQA Indoor Air Quality Analyser and may be sent to an optional Kane IRP3 Printer or to the Kane LIVE App via Wi-Fi.

The Kane AQA Indoor Air Quality Analyser is a configurable gas analyser capable of testing an array of environmental parameters.

Kane AQA Indoor Air Quality Analyser Key Features

  • A configurable gas analyser available with your choice of up to four gas sensors
  • Test an array of domestic and commercial boilers, heat pumps, flueless gas appliances, and space/water heaters
  • Perfect for testing room and workplace indoor air quality, airflow, temperature, and relative humidity
  • Four versions available: one gas, two gas, three gas, and four gas
  • Can be fitted with the gas sensor/s of your choice
  • Test type C sealed appliances, type B boiler open flue, and type A cooker and space/water heaters*
  • Measure up to four gases simultaneously*
  • Differential pressure: -80 to +80mBar*
  • CO and CO2 safety tests*
  • Gas appliance integrity tests: tightness, let by, and appliance sweep test*
  • Flueless gas appliance and space/water heater tests*
  • Room migration timed test for CO and CO2 with ambient CO2*
  • Appliance timed sweep test for CO and CO2 with ambient CO2 sensor*
  • Heat pump differential and return temperature (with optional Kane WPCP2 Clamp Probes)
  • Differential temperature: -20°C to +1350°C (with additional probes)
  • Air flow: 1.1 to 20m/s (with KANE-DTHA2)
  • Temperature: -20°C to +50°C (with KANE-DTHA2)
  • Relative Humidity: 0.1-99% (with KANE-DTHA2)
  • Room CO: 0-999ppm (with optional Kane 79 CO Monitor)
  • EN50543 for ambient CO2 and CO*
  • EN50379 for O2, CO, and NO*
  • CIS23 and BS8494 for testing commercial catering appliances for UK CP42 certificates*
  • Data Hold
  • Data logging 
  • Send data to the Kane IRP3 Printer (optional accessory)
  • Send data to the Kane Live App via Wi-Fi
  • A configurable gas analyser capable of testing an array of environmental parameters

*Dependent on the number and type of gas sensors fitted

What’s Included?

  • Your Choice of Kane AQA Indoor Air Quality Analyser
  • Your Choice of Gas Sensors (please contact us with your selection)
  • KANE-DTHA2 Anemometer
  • USB1 Charger
  • Large Carry Bag

Kane AQA Indoor Air Quality Analyser Technical Specifications

Carbon Dioxide (CO2)  0-20%
Carbon Dioxide (CO2)  0-9999ppm
Carbon Monoxide (CO) 0-2000ppm
10000ppm H2 Compensated
Nitric Oxide (NO) 0-600ppm
Oxygen (O2) 0-21%
Differential temperature -20 to +1350°C - with suitable probes
Differential pressure -80 to +80mBar
Airflow 1.1 – 20m/s with KANE-DTHA2
Temperature -20 - +50°C with KANE-DTHA2
Relative Humidity  0.1 – 99% with KANE-DTHA2
Room CO  0-999ppm with optional KANE79 CO monitor
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Kane AQA Indoor Air Quality Analyser – Choice of Gas Sensors
Your Rating
Additional Information
SKU KANE-AQAX
International Enquiry