The Megger SMRT46D is a compact, lightweight, and high-power relay test system designed for comprehensive testing of modern protective devices. With its three-channel output configuration, the SMRT46D is suitable for testing electromechanical, solid-state, and microprocessor-based protective relays, as well as motor overload relays and related protection equipment, all in a portable field-ready format.
It has an integrated on-board display for manual, steady-state, and dynamic relay testing. The system runs Megger’s Relay Test Management Software (RTMS) is directly on the unit and has a high-resolution, full-colour LCD. For users who require fully automated testing, the SMRT46D integrates seamlessly with RTMS installed on a PC.
The Style Identifcation number is 30P20C0U0S1, what this means:
The SMRT46D inclues the following accessories:
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Input Power | 90 to 264 Volts AC, 1Ø, 50/60 Hz, 1800 VA | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Per Channel Output |
|
||||||||||||||||||||||||
| Three Current Channels in Parallel |
|
||||||||||||||||||||||||
| AC Low-level Rogowski output (converted current channels)2/3 |
|
||||||||||||||||||||||||
| AC Voltage Output |
|
||||||||||||||||||||||||
| Voltage Amplifier in Current Mode |
|
||||||||||||||||||||||||
| Phase Angle, Voltage and Current | Ranges: 0.00 to 359.99 degrees, counter-clockwise, or clockwise rotation, or 0.00 to ± 180.00 degrees Accuracy: ± 0.02° typical, < 0.1 ° guaranteed at 50/60 Hz Resolution: 0.001 |
||||||||||||||||||||||||
| Frequency | Ranges DC: 0.001 to 1000.000 Hz Output amplifiers can provide transient signals with a range of DC to 10 kHz for transient playback using IEEE-C37.111 Standard COMTRADE files. Resolution: 0.001 Hz Frequency accuracy: 2.5 ppm typical 25 ppm, 0° to 50° C, at 50/60 Hz maximum AC/DC AUX: 250 ppm, 50/60 Hz maximum |
||||||||||||||||||||||||
| Total Harmonic Distortion | Less than 0.1 % typical, 2 % maximum at 50/60 Hz | ||||||||||||||||||||||||
| AC Voltage Amplitude | Accuracy: ± 0.05 % reading + 0.02 % range typical ± 0.15 % reading + 0.05 % range maximum Resolution: 0.01 Measurements: AC RMS Ranges: 30, 150, 300 V |
||||||||||||||||||||||||
| DC Voltage Amplitude | Accuracy: 0.1 % range typical, 0.25 % range maximum Resolution: 0.01 Measurements: RMS Ranges: 30, 150, 300 V |
||||||||||||||||||||||||
| AC low-level voltage output2 | Range: 2 V Accuracy: 0 – 1 V: 0.5 mV typical and 1 mV guaranteed 1 – 2 V: 0.5 mV typical and 2 mV guaranteed Resolution: 0.001 Measurements: AC RMS |
||||||||||||||||||||||||
| AC Low-level Rogowski Output (Converted current channels)2/3 | Range: 2 V Accuracy: 0 – 1 V: 0.5 mV typical and 1 mV guaranteed 1 – 2 V: 0.5 mV typical and 2 mV guaranteed Resolution: 0.001 Measurements: AC RMS Ranges: 10, 40 V Accuracy: ± 0.05 % of reading + 0.02 % of range typical ± 0.15 % of reading + 0.05 % of range guaranteed Resolution: 0.001 Measurements: AC RMS |
||||||||||||||||||||||||
| AC Low-level Voltage Output (with MLLA adapter) | Range: 2 V, 30 V Accuracy: 0 – 1 V: 0.5 mV typical and 1 mV guaranteed >1 V: 0.5 mV typical and 2 mV guaranteed Resolution: 0.001 Measurements: AC RMS |
||||||||||||||||||||||||
| AC Current Amplitude | Accuracy: ± 0.05 % reading + 0.02 % range typical ± 0.15 % reading + 0.05 % range maximum Resolution: 0.001/0.01 Measurements: AC RMS Ranges: 32, 60 A |
||||||||||||||||||||||||
| AC Low Current2 | Range: 50 mA Accuracy: ± 0.5 mA typical and 1 mA guaranteed Resolution: 0.0001 Measurements: AC RMS |
||||||||||||||||||||||||
| DC Current Amplitude | Accuracy: ± 0.05 % reading + 0.02 % range typical ± 0.15 % reading + 0.05 % range maximum Resolution: 0.001/0.01 Measurements: RMS Range: 30 A |
||||||||||||||||||||||||
| Convertible Source in AC Current Mode | Accuracy: ± 0.05 % reading + 0.02 % range typical ± 0.15 % reading + 0.05 % range or ± 12.5 mA whichever is greater Resolution: 0.001 Measurements: AC RMS Ranges: 5, 15 A |
||||||||||||||||||||||||
| Timer | Seconds: 0.0001 to 99999.9 (Auto ranging) Cycles: 0.01 to 99999.9 (Auto ranging) ± 0.001 % of reading, typical ± 2 least significant digit ± 0.005 % of reading from 0 to 50 °C maximum |
||||||||||||||||||||||||
| Binary Input - Start/Stop/Monitor Gate | Input rating: Up to 300 V AC/DC Variable voltage threshold: Range: 5 - 150 V AC/DC Accuracy: 5 - 30 V, ± 3 V 31 - 99.9 V, ± 6 V 100 - 150, ±10 V |
||||||||||||||||||||||||
| Binary Output Relays | High current output relays 1 to 4: AC rating: 400 V max., I max: 8 A, 2000 VA max. DC rating: 300 V max., I max: 8 A, 80 W Response time: < 10 ms High-speed output relays 5 and 6: AC/DC rating: 400 V peak, I max: 1 A Response time: < 1 ms typical |
||||||||||||||||||||||||
| AC/DC AUX Voltage Channel |
|
||||||||||||||||||||||||
| Battery Simulator |
|
||||||||||||||||||||||||
| Environmental | Operating temperature: 14 to 122 °F (-10 to 50 °C) Storage temperature: -13 to 158 °F (-25 to 70 °C) Relative humidity: 5 – 95 % RH, non-condensing |
||||||||||||||||||||||||
| Conformance Standards | Safety: EN 61010-1 Shock: EN/IEC 60068-2-27 Vibration: EN/IEC 60068-2-6 Transit drop: ISTA 1A Free fall: EN/IEC 60068-2-32 Drop/topple: EN/IEC 60068-2-31 Electromagnetic compatibility Emissions: EN 61326-2-1, EN 61000-3-2/3, FCC Subpart B of Part 15 Class A Immunity: EN 61000-4-2/3/4/5/6/8/11 |
||||||||||||||||||||||||
| Weight | 30.09 lb. (13.65 kg) | ||||||||||||||||||||||||
| Dimensions | 13.25 W x 6.75 H x 10.75 D in 337 W x 172 H x 273 D mm |
||||||||||||||||||||||||
| 1 Megger reserves the right to change product specifications at any time. 2 Requires VIGENS with hardware version 3.5.1 or higher. 3 For the ability to test relays with low-level inputs by simulating signals from non-conventional CTs and VTs with low-level interfaces, i.e., Rogowski coils, will require the Megger MLLA (Low Level Adapter). 4 PowerV™ voltage amplifier output current varies depending on the voltage setting on the 150 Volt range, see curve. |
|||||||||||||||||||||||||