Micronics U1000MKII WM HM Fixed Ultrasonic Clamp-on Heat Meter (IP68, 0 to +135°C) - Choice of Model

SKU
904-2000XX0X
Rating:
0%
(0)
Reward Points
:
1734
£1,734.00 £1,445.00
Free UK Delivery*
Advice & Support
Price Match Request
Micronics U1000MKII WMHM Fixed Ultrasonic Clamp-on Heat Meter
Description

These Micronics ultrasonic clamp-on thermal, heat/energy meters use ultrasound to measure flow rate and PT100 temperature sensors to measure flow and return temperatures. They display energy rate and totalised energy with pulse output and communication options, so they can be used as a standalone meter or as an integral part of an aM&T or BEM's system.

A cost-effective alternative to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability! Compact, rugged, and reliable, and designed to provide sustained performance in industrial environments.

Simple to install - connect power and enter the pipe inside diameter, adjust the sensors, and clamp on the pipe - no specialist skills or tools required!

Features

  • Clamp-on pipe-mounted sensors with Wall Mounted keypad and display for wall or panel mounting
  • Larger pipe range available in 2 options. 22mm - 115mm OD and 125mm - 225mm OD
  • Optional Modbus RTU slave, RS485 serial, and M-Bus communication
  • Ultrasonic, cross-correlation transit time method for flow measurement
  • 1Mhz transducers to get through poor/old thick wall pipes and larger pipework
  • Water/Glycol option
  • Connect power and enter the pipe inside diameter, adjust the sensors, and clamp on the pipe, no specialist skills or tools are required
  • A clamp-on non-invasive alternative heat/energy meter to traditional in-line meter installation, plus dry servicing, providing minimum downtime and maximum availability
  • LCD with backlight - install & service information
  • Integrated pulse output for Volume flow and Energy in kWh(BTU). - aM&T & BEM's compatible with Modbus

Product Range

  • Micronics 904-20001400 U1000MKII WM-HM Pulse Only, up to 4" pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20001401 U1000MKII WM-HM Pulse & 4-20mA, up to 4' Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20001402 U1000MKII WM-HM with Pulse & Modbus, up to 4' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20001403 U1000MKII WM-HM with Pulse & Mbus, up to 4' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20001404 U1000MKII WM-HM with Pulse, 4-20mA & Modbus, up to 4' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20001405 U1000MKII WM-HM with Pulse, 4-20mA & Mbus, up to 4' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004800 U1000MKII WM-HM Pulse Only, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004801 U1000MKII WM-HM Pulse & 4-20mA, up to 8' Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004802 U1000MKII WM-HM with Pulse & Modbus, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004803 U1000MKII WM-HM with Pulse & Mbus, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004804 U1000MKII WM-HM with Pulse, 4-20mA & Modbus, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
  • Micronics 904-20004805 U1000MKII WM-HM with Pulse, 4-20mA & Mbus, up to 8' pipe Fixed Ultrasonic Clamp-on Heat Meter
Tech Specs

Specification

  • Measurement Technique: Ultrasonic, cross-correlation transit time method for flow measurement
  • Turn Down Ratio: 100:1
  • Heat Meter Standard: The Heat/Energy calculation is designed to comply with EN1434 section 6.
  • Accuracy: ±1% - 3% of flow reading for velocity rate >0.3m/s (>1 ft/s)
  • Flow Velocity Range: 0.1m/s - 10m/s (0.3 ft/s - 32 ft/s)
  • Pipe Material: Steel, Stainless Steel, Plastic, and Copper
  • Water Temp Range: 0°C - 135°C (32°F - 275°F)
  • Temperature Sensors: Clamp-on PT100 Class B 4 wire, range 0°C - 135°C (32°F - 275°F), resolution 0.1°C (0.18°F). The Minimum delta T is 0.3°C
  • Pulse Output: Pulse or Frequency. Pulse for Volume flow and Energy in kWh(BTU). Frequency for flow rate. The pulse output can be configured as a loss of signal or low flow alarm. Opto-isolated MOSFET volt free contact (NO/NC)
  • Modbus Communication: Optional Modbus RTU slave, RS485 serial link hardware layer. Energy, power, temperature, and flow
  • Mbus Communication: Optional
  • External Power Supply: 12V - 24V ±10% AC/DC at 7 watts per unit. Optional plug-in 12V power supply
  • Electronics Enclosure: IP68
  • Wall Mounted Keypad and Display Dimensions: 215mm x 125mm x 90mm (8.46"x 4.92" x 3.54")