The Siglent SHA860A series analysers are intended for 5G and LTE field environments. The SHA861A covers 9 kHz to 3.6 GHz, and the SHA862A extends up to 7.5 GHz. Both models have an optional real-time analysis bandwidth of up to 110 MHz and a DANL as low as -165 dBm/Hz. They include 5G NR and LTE OTA testing, IQ data acquisition, pulse profile analysis, and GPS-assisted indoor/outdoor mapping.
SHA861A | SHA862A | |
---|---|---|
SA Frequency Range | 9 kHz~3.6 GHz, 5 kHz usable | 9 kHz~7.5 GHz, 5 kHz usable |
VNA Frequency Range | 100 kHz~3.6 GHz, 30 kHz usable | 100 kHz~7.5 GHz, 30 kHz usable |
CAT Frequency Range | 100 kHz~3.6 GHz, 30 kHz usable | 100 kHz~7.5 GHz, 30 kHz usable |
DANL | -165 dBm/Hz | |
Phase Noise (1 GHz, Typ.) | -104 dBc/Hz.@ 10 kHz offset | |
Analysis Bandwidth | 40 MHz / 110 MHz (opt.) | |
Preamplifier | Standard | |
Dynamic Range | 114 dB | |
Other Functions | Advanced Measurement Kit, Analogue Modulation Analysis, Digital Modulation Analysis, GPS Location, Outdoor/Indoor Map, Independent Source, DC Bias Out, 5G NR OTA Measurement, LTE TDD/FDD OTA Measurement, Real-Time Spectrum Analysis, IQ Data Acquisition, Pulse Profile Analysis, etc. | |
Display | TFT LCD, 800 × 600, 8.4-inch multi-touch screen | |
Battery | 2.5 hours | |
Power Consumption | 27 W (typ.) | |
Dimensions | 310 mm x 215 mm x 78.5 mm (WxHxD) | |
Weight | Net: 3.20 kg (7.0 lb) | |
Storage | Internal (Flash) 3.2 GB, external (USB storage device) 32 GB | |
Source | AC voltage range: 100-240 V, 50/60 Hz or 100-120 V, 400 Hz | |
Power Consumption | 27 W (typ.) | |
Temperature | Working temperature: 0 °C to 50 °C Working while charging temperature: 0 °C to 45 °C Storage temperature: -20 °C to 70 °C |
|
Humidity | 0 °C to 30 °C, ≤ 95% Relative humidity 30 °C to 50 °C , ≤ 75% Relative humidity |
|
Altitude | Operating: less than 3 km (10000 feet) | |
Calibration Cycle | 1-year | |
EN 61326-1: 2013 / EN 61000-3-2: 2014 | Class A (The active input power of the EUT is less than 75 W. According to EN 61000-3-2, no limits are necessary.) | |
EN 61000-3-3: 2013 | Plt: 0.65 Pst: 1.00, dmax: 4.00 % dc: 3.00 % EN 61000-3-3: 2013 dt Lim: 3.30 % dt>Lim: 500ms |
|
Safety | CAN/CSA-C22.2 No. 61010-1:2012/A1:2018-11 CAN/CSA-C22.2 No. 61010-2-030:2018 UL 61010-1:2012/R:2018-11 UL 61010-2-030:2018 |
|
RoHS | 2011/65/EU |