The Wöhler 1388 infrared thermometer (IR) enables a contactless temperature measurement on e.g. wall surfaces or even in inaccessible places. Thermal bridges can be detected with this IR thermometer. Temperature differences are detected in real-time using infrared radiation at small but also large distances.
The operation of the measuring device is very easy: at the beginning, the emission factor has to be selected directly at the IR-thermometer, then you mark the temperature measuring point with the spot laser beam. The temperature can be read directly from the color display of the infrared thermometer and stored.
Measurement Range | - 60 to + 550°C (-76 to + 1022°F) |
---|---|
Operating Temperature | - 0 to + 50°C (32 to + 122°F) |
Accuracy, IRT 15 - 35 °C, TAmb 25 °C | ± 1.0 °C (1.8°F) |
Accuracy, IRT= -60 to 0°C: TAmb = 23°C ± 3.0°C | ± (2+ 0.05/°C) °C |
Accuracy, IRT= 0 to 550 °C, TAmb 23°C ± 3.0°C | 2% of reading or 2°C (4°F), whichever is higher |
Emissivity Range | 0,95 default, adjustable 0,1 bis 1 |
Distance / Spot | 12:1 |
Resolution | 0,1°C (0,1 °F) at -82,2 to 999,9 (°C/°F), otherwise 1 °C/°F |
Response Time (90%) | 1 sec |
Relative Humidity (RH), (Tamb 23°C ±5°C) Mesurement Range | 1 to 99% |
Relative Humidity (RH), (Tamb 23°C ±5°C) Accuracy | ± 3% at 20~80%, otherwise ±5% |
Dry Bulb Temperature Measurement Range | -20 to 65 °C |
Dry Bulb Temperature Accuracy | ± 2.5 °C |
Wet Bulb Temperature Measurement Range | -20 to 65 °C |
Wet Bulb Temperature Accuracy | ± 2.5 °C |
Dew Point Temperature (DPT) Mesurement Range | -50 to 50°C |
Dew Point Temperature (DPT) Accuracy | ± 2,5°C, at 20 to 30% RH ±2°C at 31 to 40% RH ±1.5°C at 41~95 % RH |
Internal Memory | 50 memories with temperature and emissivity |
Battery Life | Min. 30 h without Laser Min. 7 h with Laser |
Dimensions | 53 x 124 x 171mm |
Weight | 240 g with 2 batteries (AAA) |