The FLIR EV86-T2 is an all-in-one EV charger analyser for safety and performance testing of AC EV charging stations in residential and commercial environments. It supports Level 1 and Level 2 chargers and features an integrated Type 2 connector and compact Type 1 adapter, with automated test sequences, pre-test voltage verification and clear pass/fail results.
The EV86-T2 provides EVSE diagnostics, including Control Pilot (CP) state simulation, CP waveform analysis, RCD performance verification, error simulation, and low-impedance measurement, to help identify charger faults. Protective Earth (PE) pre-testing verifies that no hazardous voltage is present before testing.
Bluetooth Low Energy (BLE) connectivity allows the analyser to connect to the FLIR Meterlink app for wireless data transfer, report generation, data management and sharing from a mobile device.
Get a free gift this Black! Even better, this bonus stacks with any other offer.
Free item will automatically add to your basket. Limited Stock. Offer is based on ex VAT basket total after discounts and before shipping costs. See Black Friday Offers for details.
Remember: We will not be beaten on price. Contact us if you've seen a cheaper price.
| Measurement & Analysis | |
|---|---|
| Auto Testing Items | PE Pre-Test, EVSE Interface, RCD Test, and Loop Impedance in Settings Menu |
| Category Rating | CAT II-300 V |
| CP Error (E state) Simulation | Pass/Fault |
| EVSE Interface | 1 Φ: 250 V max, 3 Φ: 230 / 440 V max, 50 / 60 Hz, max 10 A Main Voltage: Range 440 V / Accuracy: +/- 2.0% Frequency Range: 2 kHz / Accuracy: +/- 1 Hz Duty Cycle Range:100% / Accuracy: +/- 5 Digits |
| Loop Impedance | Range: 2.000 kΩ / Accuracy: ±1.0% |
| PE Pre-Test | Range: 50 V AC/DC / Accuracy: ±2.0%, Pass / Fault (>50 V AC/DC between PE Conductor and Touch Sensor) |
| PP State Simulation | Not connected, Connected, Connected + Latch |
| RCD/CCID Trip Test | RCD Trip Time (0°, 180°) Range: 31.5 mA AC, 300 ms / Accuracy ±2.0% Range: 6 mA DC, 12.5s for < 2.5s / Accuracy ±1.0% RCD Ramping Current (0°, 180°) Range: 6 mA DC in 2.5s Smooth Ramp Every 2 mA DC 30 mA AC in 2mA Steps Every 300 ms in .5s / Accuracy ±2.0% |
| Voltage Phase Indication | L1, L2, L3, PE, N |
| Communication & Data Storage | |
| Display Size | 3.5 in. TFT-LCD |
| Connectivity | Bluetooth BLE with 10 m (32 ft) range |
| Connector Types | Type 2 (Built-in), Type 1 (converter included) |
| Power | |
| Auto Power Off | Off / 5 min / 10 min / 20 min / 30 min |
| Battery | Rechargeable Li-Battery |
| Battery Life | 12 Hours Continuously |
| General | |
| Size (L x W x H) | 296 x 94 x 50 mm (11.6 x 3.7 x 2 in.) |
| Weight | 760 g (1.7 lbs) |
| Environmental & Certifications | |
| Certifications | ETL, CE, FCC |
| EMC | EN61326-1 |
| Operating Altitude | 2000 m (6560 ft) |
| Operating Ambient Temperature and Relative Humidity (RH) | -10°C to 30°C (14°F to 86°F) <85% RH 30°C to 40°C (86°F to 104°F) <75% RH 40°C to 50°C (104°F to 122°F) <45% RH |
| Pollution Degree | 2 |
| Safety Category | CAT II-300 V IEC61010-1 |
| Storage Temperature and Relative Humidity [RH] | -20°C to 60°C (-4°F to 140°F) >0 to 80% RH |
| FLIR Warranty | Limited 3-Year Warranty |