All Fluke Products

Fluke 393FC TRMS Solar Clamp Meter, IRR1-SOL Irradiance Meter & Pomona MC4 Test Leads – Kit 2

SKU
5337401
Rating:
0%
(0)
Reward Points
:
735
£882.00 £735.00
Only 1 in Stock Free UK Delivery*
Advice & Support
Price Match Request
Fluke 393FC TRMS Solar Clamp Meter, Irradiance Meter & Pomona Test Leads
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Claim direct to Fluke with your invoice. T&Cs apply.

This kit is ideal for solar photovoltaic (PV) installation technicians and maintenance professionals working in high-voltage DC environments. It includes:

  • Fluke 393FC Solar Clamp Meter with Accessories
  • Fluke Pomona PVLEAD1 MC4 Solar Test Leads
  • Fluke Pomona PVLEAD3 MC4 Solar Test Leads
  • Fluke IRR1-SOL Solar Irradiance Meter with Accessories

Fluke 393FC True-RMS Solar Clamp Meter Overview

The Fluke 393FC True-RMS Solar Clamp Meter is an IP54-certified, CAT III 1500V-safety-rated AC/DC clamp designed to measure 1500V DC systems. Its thin jaws enable access to cables in crowded combiner boxes. The following parameters can be measured via the Fluke 393FC’s Clamp:

  • DC voltage: up to 1500V
  • AC voltage: up to 1000V
  • AC/DC: up to 999.9A

Fluke 393 FC 1500 V Clamp Meter | What It Does And How It Works

In addition to this, the Fluke 393FC True-RMS Solar Clamp can measure DC power (kVA) and features audio polarity and visual continuity indicators. Furthermore, an iFlex Flexible current probe extends the Fluke 393FC True-RMS Solar Clamp’s AC range to 2500A and facilitates access to tight spaces.

Fluke Connect technology allows you to log results wirelessly to the Fluke Connect App. Once saved to the Fluke Connect App, data can be analysed, shared, or used to create reports.

The Fluke 393FC True-RMS Solar Clamp is ideal for checking solar arrays, wind power equipment, electric railways, data centres, and battery banks.

Please click here for more information about the Fluke 393FC True-RMS Solar Clamp.

Fluke Pomona PVLEAD1 MC4 Solar Test Leads Overview

Ideal for regular testing, measuring, and troubleshooting of solar PV panels, the Fluke Pomona PVLEAD1 MC4 Solar Test Leads allow you to connect test tools that accept 4mm banana plugs (such as the Fluke 393FC Solar Clamp Meter) to PV panels, modules, and systems. Via this connection, you can measure voltage and current safely. The Fluke Pomona PVLEAD1 MC4 Solar Test Leads are CAT III 1000V/ CAT IV 600V safety rated and comply with 20A ratings according to IEC/EN 61010-031.

Fluke Pomona PVLEAD3 MC4 Solar Test Leads Overview

Specifically designed for use with solar clamp meters that accept 4mm banana plugs, such as the Fluke 393FC Solar Clamp Meter, the Fluke Pomona PVLEAD3 MC4 Solar Test Leads facilitate a connection between the solar panel and inverter enabling troubleshooting and maintenance inspections. They ensure that you can take safe DC power measurements on PV modules and systems without interrupting power generation. The Fluke Pomona PVLEAD3 MC4 Solar Test Leads are CAT III 1000V/ CAT IV 600V safety rated and comply with 20A ratings by IEC/EN 61010-031.

Fluke IRR1-SOL Solar Irradiance Meter Overview

Ideal for solar installers and technicians working on roof-mounted systems or large-field installations, the Fluke IRR1-SOL Solar Irradiance Meter provides a simple solution to installing, testing, and maintaining solar panels by IEC 62446-1 requirements. This rugged, compact meter with a high-contrast display can measure solar arrays' irradiance, temperature, inclination, and direction. To this end, the Fluke IRR1-SOL Solar Irradiance Meter includes a high-precision mono-crystalline solar sensor, two temperature measurement options, an integrated compass, and an inclination sensor.

Introducing the Fluke IRR1-SOL Irradiance Meter

Follow this link to read more about the Fluke IRR1-SOL Solar Irradiance Meter.

What’s Included?

Fluke 393 FC CAT III 1500V True-RMS Clamp Meter with iFlex Technical Specifications 

General
Maximum voltage between any Terminal and Earth Ground
AC 1000 V
DC 1500 V
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic Power Off 20 minutes
Electrical 
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 75 %. Accuracy specifications take the form of ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw  
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 2.5 @600.0 A
3.0 @500.0 A
1.42 @999.9 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range 999.9 A
  2500 A
Resolution 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz) 2.5 @1400 A
3.0 @1100 A
1.42@2500 A
Add 2 % for C.F. >2
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % RD + 5 digits[1]
Note [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage 
Range 600.0 V
1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
DC Voltage 
Range 600.0 V
1500 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy 1 % RD + 5 digits
mV DC
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % RD + 5 digits
Amps Frequency: Jaw 
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power 
Range 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution 0.1 kVA
1 kVA
Accuracy 2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance 
Range 600.0 Ω
6000 Ω
60.00 kΩ
Resolution 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy 1 % RD + 5 digits
Capacitance
Range 100.0 μF
1000 μF
Resolution 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy 1 % RD + 5 digits
Inrush Trigger Level 5 A
Mechanical
Size (L x W x H) 281 mm x 84 mm x 49 mm
Weight (with batteries) 520 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length (head to electronics connector) 1.8 m
Environmental 
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C
Operating Humidity Non condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating Altitude 2000 m
Storage Altitude 12 000 m
Ingress Protection (IP) Rating IEC 60529: IP54 non-operating
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety 
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radiofrequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz
Output Power <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this product complies with Directive 2014/53/EU.

Fluke IRR1-SOL Solar Irradiance Meter Technical Specifications 

Irradiance 
Measuring Range 0 to 1400 W/m²
Resolution 1 W/m²
Measuring Accuracy ± (5 % + 5 Digit)
Temperature Measurement 
Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution 0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C)
and 167 °F to 212 °F (75 °C to 100 °C)
Note Temperature measurement response time: ~30 sec
Inclination Angle
Measuring Range -90° to +90°
Resolution 0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°
±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range 0° to 360°
Resolution
Measuring Accuracy ± 7°
Note a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown “---”.
b) Result is referred to as magnetic north.
Temperature
Operating Temperature IRR1-SOL -20 °C to 50 °C (humidity <80 %), non-condensing
Operating Temperature 80PR-IRR -30 °C to 100 °C
Storage Temperature -30 °C to 60 °C (humidity <80 %)
Altitude 0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively coupled radiofrequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such
environments.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection 
IP Protection IP40
Power Supply & Battery Life
Batteries 4 AA Alkaline Batteries
Battery Life (typical) 50 hours (> 9000 readings)
Auto Power Off 30 minutes
Dimensions
L x W x H 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight 0.5 lb (231 g)
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 393FC TRMS Solar Clamp Meter, IRR1-SOL Irradiance Meter & Pomona MC4 Test Leads – Kit 2
Your Rating
Additional Information
SKU 5337401
Manufacturer Part Code 5337401
Country of Origin China
International Enquiry