Fluke 5615 Secondary Reference Temperature Standard Probes - Choice of Termination
Description
Buy a Fluke Get a Free Fluke Logo

* Buy a Fluke (Worth £150+ Ex VAT) and Choose a Free Fluke!

Available until 31/08/24. For more details and to see your choice of free Fluke tool - View Offer

Only available from authorised Fluke distributors, such as PASS Ltd. Claim direct to Fluke with your invoice. T&Cs apply.

A secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. Excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. 17025 accredited calibration included. Traceable to NIST standards. Termination ranges available from A to S. Termination Key

Product Ranges

  • Fluke 5615-6-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-6-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
  • Fluke 5615-9-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-9-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
  • Fluke 5615-12-A Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-B Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-D Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-G Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-J Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-L Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-M Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-P Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-12-S Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
  • Fluke 5615-9BND-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Fluke 5615-9BND-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
  • Termination Key:
  • A- (INFO-CON for 914X)
  • B - Bare wire
  • D - 5-pin DIN for Tweener Thermometers
  • G - Gold pins
  • J - Banana plugs
  • L - Mini spade lugs
  • M - Mini banana plugs
  • P - INFO-CON for 1523 or 1524
  • S - Spade lugs
Tech Specs
Specifications
Temperature Range 5615-12 and 5615-9: -200 °C to 420 °C
5615-6: -200 °C to 300 °C
Nominal Resistance at 0 °C 100 Ω ± 0.10 Ω
Temperature Coefficient 0.0039250 Ω/Ω/°C
Accuracy1 ± 0.024 °C at -200 °C
± 0.012 °C at 0 °C
± 0.035 °C at 420 °CC
Short-Term Repeatability2 ± 0.009 °C at 0.010 °C
Drift3 ± 0.007 °C at 0.010 °C
Sensor Length 28 mm (1.1 in)
Sensor Location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in)
Sheath Dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in)
5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in)
5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in)
Sheath Diameter Tolerance ± 0.127 mm (± 0.005 in)
Sheath Material Inconel 600
Minimum Insulation Resistance 1000 MΩ at 23 °C
Transition Junction Temperature Range -50 °C to 200 °C
Transition Junction Dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in)
Maximum Immersion Length 5615-6: 102 mm (4 in)
5615-9: 178 mm (7 in)
5615-12: 254 mm (10 in)
Response Time5 9 seconds typical
Self Heating (in 0 °C bath) 50 mW/°C
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22 AWG
Lead-Wire Length 183 cm (72 in or 6 ft)
Lead-Wire Temperature Range -50 °C to 200 °C
Calibration NVLAP-accredited calibration included, lab code 200706-0.
Please see calibration uncertainty table and its explanation of changeable uncertainties.
1 Includes calibration and 100 hr drift (k=2)
2 Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2)
3 After 100 hrs at max temp, 95 % confidence (k=2)
4 Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch
5 Per ASTM E 644
NVLAP† Calibration Uncertainty
Temperature Expanded Uncertainty (k=2)
-196 °C 0.024 °C
-38 °C 0.011 °C
0 °C 0.010 °C
200 °C 0.018 °C
420 °C‡ 0.029 °C
Note: Calibration uncertainties depend on the uncertainties of the lab performing the calibration.
Subsequent calibrations of this probe performed with different processes, at different facilities,
or with changed uncertainty statements may state different uncertainties.
†Lab code 200706-0 ‡5615-6 excluded
0 Reviews Overall Rating
Write a Review
Write Your Own Review
You're reviewing:Fluke 5615 Secondary Reference Temperature Standard Probes - Choice of Termination
Your Rating
Additional Information
SKU 5615-PROBES
International Enquiry