Description
A secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. Excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. 17025 accredited calibration included. Traceable to NIST standards. Termination ranges available from A to S. Termination Key
Product Ranges
- Fluke 5615-6-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-6-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 6")
- Fluke 5615-9-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-9-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9")
- Fluke 5615-12-A Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-B Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-D Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-G Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-J Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-L Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-M Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-P Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-12-S Secondary Reference Standard Probe, PRT, 100 Ohm (1/4 × 12")
- Fluke 5615-9BND-A Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-B Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-D Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-G Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-J Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-L Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-M Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-P Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Fluke 5615-9BND-S Secondary Reference Standard Probe, PRT, 100 Ohm (3/16 × 9") 90° Bend
- Termination Key:
- A- (INFO-CON for 914X)
- B - Bare wire
- D - 5-pin DIN for Tweener Thermometers
- G - Gold pins
- J - Banana plugs
- L - Mini spade lugs
- M - Mini banana plugs
- P - INFO-CON for 1523 or 1524
- S - Spade lugs
Tech Specs
Specifications | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | 5615-12 and 5615-9: -200 °C to 420 °C 5615-6: -200 °C to 300 °C |
||||||||||||||||
Nominal Resistance at 0 °C | 100 Ω ± 0.10 Ω | ||||||||||||||||
Temperature Coefficient | 0.0039250 Ω/Ω/°C | ||||||||||||||||
Accuracy1 | ± 0.024 °C at -200 °C ± 0.012 °C at 0 °C ± 0.035 °C at 420 °CC |
||||||||||||||||
Short-Term Repeatability2 | ± 0.009 °C at 0.010 °C | ||||||||||||||||
Drift3 | ± 0.007 °C at 0.010 °C | ||||||||||||||||
Sensor Length | 28 mm (1.1 in) | ||||||||||||||||
Sensor Location | 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in) | ||||||||||||||||
Sheath Dimensions | 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in) 5615-9: 229 mm x 4.76 mm (9.0 in x 0.188 in) 5615-12: 305 mm x 6.35 mm (12.0 in x 0.250 in) |
||||||||||||||||
Sheath Diameter Tolerance | ± 0.127 mm (± 0.005 in) | ||||||||||||||||
Sheath Material | Inconel 600 | ||||||||||||||||
Minimum Insulation Resistance | 1000 MΩ at 23 °C | ||||||||||||||||
Transition Junction Temperature Range | -50 °C to 200 °C | ||||||||||||||||
Transition Junction Dimensions | 71 mm x 13 mm dia (2.8 in x 0.5 in) | ||||||||||||||||
Maximum Immersion Length | 5615-6: 102 mm (4 in) 5615-9: 178 mm (7 in) 5615-12: 254 mm (10 in) |
||||||||||||||||
Response Time5 | 9 seconds typical | ||||||||||||||||
Self Heating (in 0 °C bath) | 50 mW/°C | ||||||||||||||||
Lead-Wire Cable Type | PTFE insulated with PTFE jacket, 22 AWG | ||||||||||||||||
Lead-Wire Length | 183 cm (72 in or 6 ft) | ||||||||||||||||
Lead-Wire Temperature Range | -50 °C to 200 °C | ||||||||||||||||
Calibration | NVLAP-accredited calibration included, lab code 200706-0. Please see calibration uncertainty table and its explanation of changeable uncertainties. |
||||||||||||||||
1 Includes calibration and 100 hr drift (k=2) 2 Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k=2) 3 After 100 hrs at max temp, 95 % confidence (k=2) 4 Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch 5 Per ASTM E 644 |
|