Description
A notable advantage to the RTD sensor is that it conforms to the standard 385 curves, letting you fully use your DIN/IEC RTD meters. Each probe is individually calibrated and includes an NVLAP-accredited report of calibration from the manufacturer, lab code 200706-0. 17025 accredited calibration included. Traceable to NIST standards. Termination ranges available from A to S. Termination Key.
Product Ranges
- Fluke 5627A-6-A Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-B Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-D Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-G Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-J Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-L Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-M Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-P Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-6-S Precision Industrial RTD Probe, 100 Ohm 3/16 × 6"
- Fluke 5627A-9-A Precision Industrial RTD Probe, 100 Ohm 3/16 × 9"
- Fluke 5627A-9-B Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-D Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-G Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-L Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-M Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-P Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-9-S Precision Industrial RTD Probe, 100 Ohm 3/16 × 9" Simple
- Fluke 5627A-12-A Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-B Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-D Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-G Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-L Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-M Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-P Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-12-S Precision Industrial RTD Probe, 100 Ohm 1/4 × 12"
- Fluke 5627A-CLEN-S Precision Industrial RTD Probe, 1/4 × 12" Cable
- Termination Key:
- A (INFO-CON for 914X)
- B (Bare wire)
- D (5-pin DIN for Tweener Thermometers)
- G (Gold pins)
- J (Banana plugs)
- L (Mini spade lugs)
- M (Mini banana plugs)
- P (INFO-CON for 1523 or 1524)
- S (Spade lugs)
Tech Specs
Specifications | |
---|---|
Resistance | Nominal 100 Ω |
Temperature Coefficient | 0.00385 Ω/Ω/ °C nominal |
Temperature Range | -200 °C to 420 °C (5627A-6 and 5627A-9 to 300 °C transition and cable temperature: 0 °C to 150 °C) |
Drift Rate (k=2) | ± 0.04 °C at 0 °C after 100 hours at 420 °C |
Sheath Material | 316 Stainless Steel |
Leads | PTFE-insulated, nickel-plated stranded copper, 22 AWG |
Termination | A, B, D, G, J, L, M, P, S |
Time Constant | Four seconds maximum for 63.2 % response to step-change in water moving at 3 fps |
Bending Radius | The sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for the 50 mm (2 in) area of the sheath near the tip (Fluke lab requires 20 cm [8 in] of the unbent sheath to re-calibrate) |
Calibration | Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C (to 300 °C for 5627A-6 and 5627A-9) ITS-90 coefficients included |
Immersion | At least 100 mm (4 in) recommended |
Calibrated Accuracy† (k=2) | ± 0.026 °C at -196 °C ± 0.046 °C at 0 °C ± 0.077 °C at 200 °C ± 0.124 °C at 420 °C |
Size | 5627A-12: 305 mm x 6.35 mm (12 in x 1/4 in) 5627A-9: 229 mm x 4.7 mm (9 in x 3/16 in) 5627A-6: 152 mm x 4.7 mm (6 in x 3/16 in) |
†Includes calibration uncertainty and 100 hr drift |
0 Reviews
Overall Rating
Additional Information
SKU | 5627-PROBES |
---|