The Hanna HI-6321 is a high-performance conductivity meter with a sleek, modern design. It has an intuitive interface, Wi-Fi, Ethernet, USB, direct connection options, plus built-in on-screen tutorials.
An included HI-7631233 four-ring probe measures conductivity (μS/cm, mS/cm), resistivity (Ω・cm, kΩ・cm, MΩ・cm), TDS (ppm, ppt), and salinity (ppt, PSU, %). The integrated temperature sensor helps the probe adjust conductivity readings to reference temperatures.
The HI-6321 measures conductivity, TDS, salinity, and resistivity in multiple units:
Five measurement display options are available for analytical preferences:
Conductivity | |
---|---|
Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
Accuracy | ±1 % of reading (±0.01 μS/cm) |
Resistivity | |
Range | 1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm |
Resolution | 0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm |
Accuracy | ±1 % of reading (±1 Ω・cm) |
Total Dissolved Solids (TDS) | |
Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
Accuracy | ±1 % of reading (±1 0.01 ppm) |
Salinity | |
Range | 0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale |
Resolution | 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale |
Accuracy | ±1 % of reading |
Temperature | |
Range | −20.0 to 120.0 °C; 253.0 to 393.0 K |
Resolution | 0.1 °C; 0.1 °F; 0.1 K |
Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
Conductivity Calibration | |
Calibration points | Auto standard recognition / User standard, Single Point / Multi Point calibration |
Standard solutions | 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm |
Reminder | Disabled Daily: 0 min. to 23 hours and 59 min. Periodic: 1 min. to 500 days, 23 hours and 59 minutes. |
Resistivity Calibration | Uses Conductivity |
Salinity Calibration | 1 point for Percent Scale |
Temperature Compensation | Automatic or Manual |
Reading | |
Modes | Direct Direct/Autohold |
Stability criteria | Accurate Medium Fast |
Sampling rate | 1000 ms |
EC Views | |
Basic | Measurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status |
Simple GLP | Basic view information Last calibration date, offset |
Full GLP | Simple GLP information and calibration point details |
Table | Measurements updated every second are displayed in the table |
Graph (Plot) | Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) |
Logging | |
Type | Automatic, Manual, Autohold |
Number of records | 50,000 maximum per file Stores at least 1,000,000 data points per user |
Automatic interval | 1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
Sample ID | Incremental mode |
Export option | .csv file format |
Users | Up to 9 users and the default administrator account |
Connectivity | |
USB-A | 2 ports for keyboard input or USB thumb drive |
USB-C | 1 port for PC connectivity and a USB-C type thumb drive |
Wi-Fi & Ethernet | FTP Web server Log transfer and download |
RS232 | Connecting peripherals |
Power supply | DC adapter 100-240AC to 24VDC 2.5A |
Environment | 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
Weight | Approximately 1.2 kg (26.5 lbs.) |