The Hanna HI-98197 is a waterproof, portable EC (conductivity) meter ranging from 0.000 µS/cm to 400 mS/cm, TDS (Total Dissolved Solids), resistivity, and three salinity scales. It has a quick-connect four-ring probe for adjusting the nominal cell constant and is ready to perform all three stages of the USP <645>.
The Hi-98197 monitors the efficiency of a mixed bed resin or equivalent system that produces high-purity water of 18.2 MΩ•cm at 25°C. EC and TDS measurements are fully customisable and include cell constant selection between 0.010 and 10.000, selection of linear or natural water (non-linear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00.
EC Range | 0.000 to 9.999 μS/cm 10.00 to 99.99 μS/cm 100.0 to 999.9 μS/cm 1.000 to 9.999 mS/cm 10.00 to 99.99 mS/cm 100.0 to 1000.0 mS/cm (actual conductivity temperature compensated to 400 mS/cm) |
EC Resolution | 0.001 μS/cm 0.01 μS/cm 0.1 μS/cm 0.001 mS/cm 0.01 mS/cm 0.1 mS/cm |
EC Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater) |
EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
TDS Range | 0.00 to 99.99 ppm 100.0 to 999.9 ppm 1.000 to 9.999 ppt (g/L) 10.00 to 99.99 ppt (g/L) 100.0 to 400.0 ppt (g/L) |
TDS Resolution | 0.01 ppm 0.1 ppm 0.001 ppt (g/L) 0.01 ppt (g/L) 0.1 ppt (g/L) |
TDS Accuracy | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater) |
TDS Calibration | based on conductivity calibration |
Resistivity Range | 1.0 to 99.9 Ω•cm 100 to 999 Ω•cm 1.00 to 9.99 KΩ•cm 10.0 to 99.9 KΩ•cm 100 to 999 KΩ•cm 1.00 to 9.99 MΩ•cm 10.0 to 100.0 MΩ•cm |
Resistivity Resolution | 0.1 Ω•cm 1 Ω•cm 0.01 KΩ•cm 0.1 KΩ•cm 1 KΩ•cm 0.01 MΩ•cm 0.1 MΩ•cm |
Resistivity Accuracy | ±1% of reading (±10 Ω or 1 digit, whichever is greater) |
Resistivity Calibration | based on conductivity calibration |
Salinity Range | % NaCl: 0.0 to 400.0% practical salinity: 0.00 to 42.00 (PSU) natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt) |
Salinity Resolution | 0.1%; 0.01 |
Salinity Accuracy | ±1% of reading |
Salinity Calibration | max. one point only in % range (with HI7037 standard) Use conductivity calibration for all other ranges |
Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy | ±0.2°C; ±0.4°F (excluding probe error) |
Temperature Calibration | one or two points |
Temperature Compensation | noTC, Linear (-20 to 120 °C, -4 to 248°F) Non Linear - ISO/DIN 7888 (-0 to 36 °C, 32 to 96.8°F) |
Measurement Modes | autorange, autoend, lock and fixed range |
Reference Temperature | 15°C, 20°C and 25°C |
Temperature Coefficient | 0.00 to 10.00 %/°C |
TDS Factor | 0.40 to 1.00 |
Electrode/Probe | HI-763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included) |
Log-on-demand | 400 samples lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) |
Memorised Profiles | up to 10 |
PC Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable |
Battery Type/Life | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
Auto-off | user selectable: 5, 10, 30, 60 min or can be disabled |
Environment | 0 to 50°C (32 to 122°F) RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Hanna Instruments Warranty | 2 years (probe 6 months) |