This high-performance Martindale CM57 is an AC clamp meter with TRMS which ensures more reliable readings. The CM57 covers a whole range of tests from AC current unto 600A, AC/DC voltage up to 600V, resistance with continuity test, capacitance, frequency and diode testing, and with the inbuilt smart function, the meter will automatically switch between resistance and capacitance measurements.
It features a 25.4mm opening jaw which has a built-in non-contact voltage sensor for detecting the presence of AC voltages making it even quicker, easier and safer!
Key Features
- TRMS Meter
- Voltage, Resistance, Continuity, Capacitance, Frequency and Diode tests
- Auto-ranging
- Auto switching between resistance and capacitance measurements
- Thumbwheel Control
- Auto Power-Off
- Backlit Display
- 10mA resolution
- Built-in non-contact voltage sensor
- CAT III 600 Rated
- LCD with maximum reading 5999
- Low Battery Indication
What’s Included?
- Martindale TL16 Test Leads
- Soft Carry Case
- Batteries
Martindale CM57 AC TRMS Clamp Meter Technical Specifications
Martindale CM57 TRMS AC Clamp Meter | ||||
DC Voltage | ||||
Range | Resolution | Input Impedance | Accuracy | |
6V | 0.001V | 10MΩ | 1.0% + 3 | |
60V | 0.01V | |||
600V | 0.1V | |||
Overload protection: 660V DC or AC rms | ||||
AC Voltage | ||||
Range | Resolution | Input Impedance | Accuracy (50 to 400Hz) |
|
6V | 0.001V | 10Ω | 1.2% + 5 | |
60V | 0.01V | |||
600V | 0.1V | |||
Frequency | ||||
Measurement Function |
Range | Resolution | Sensitivity | Accuracy |
AC Current | 6Khz | 0.001Khz | 3A | 0.2% + 2 |
10Khz | 0.01Khz | 5A | ||
AC Voltage | 6Khz | 0.001Khz | 5V rms | |
60Khz | 0.01Khz | |||
100Khz | 0.1Khz | |||
Capacitance | ||||
Range | Resolution | Max. Test Voltage | Accuracy | |
6nF | 0.001nF | -1.5V DC | 3.0% + 30 | |
60nF | 0.01nF | 3.0% + 10 | ||
600nF | 0.1nF | |||
6µF | 0.001µF | |||
60µF | 0.01µF | |||
600µF | 0.1µF | |||
Minimum Capacitance Measurement 0.3nF | ||||
Overload Protection 450V DC or AC ms | ||||
AC Current | ||||
Range | Resolution | Accuracy | ||
(50-60Hz) | (60-400Hz) | |||
60A | 0.01A | 1.9% + 5 | 3.0% + 5 | |
600A | 0.1A | |||
Resistance | ||||
Range | Resolution | Sensitivity | Accuracy | |
600 Ω | 0.1Ω | 1.5V DC | 1.2% + 3 | |
6KΩ | 0.001KΩ | |||
60KΩ | 0.01KΩ | |||
600KΩ | 0.1KΩ | |||
6MΩ | 0.001MΩ | |||
Continuity | ||||
Open Circuit Voltage | -1.5V DC |
|||
Audible Indication | ≼30Ω | |||
Overload protection 450V DC or AC rms |
Accessories related to this product:
0 Reviews
Overall Rating
Additional Information
SKU | MARCM57 |
---|---|
Manufacturer Part Code | MARCM57 |